Further improvements on impedance-based fault location for power distribution systems
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
In this study, further improvements regarding the fault location problem for power distribution systems are presented. The proposed improvements relate to the capacitive effect consideration on impedance-based fault location methods, by considering an exact line segment model for the distribution line. The proposed developments, which consist of a new formulation for the fault location problem and a new algorithm that considers the line shunt admittance matrix, are presented. The proposed equations are developed for any fault type and result in one single equation for all ground fault types, and another equation for line-to-line faults. Results obtained with the proposed improvements are presented. Also, in order to compare the improvements performance and demonstrate how the line shunt admittance affects the state-of-the-art impedance-based fault location methodologies for distribution systems, the results obtained with two other existing methods are presented. Comparative results show that, in overhead distribution systems with laterals and intermediate loads, the line shunt admittance can significantly affect the state-of-the-art methodologies response, whereas in this case the proposed developments present great improvements by considering this effect.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Radial distribution test feeders
Kersting, W. H. (1991) · IEEE Transactions on Power Systems · doi:10.1109/59.119237 · Cited by 1,888
Distribution System Modeling and Analysis
Kersting, W. (2012) · Electric Power Engineering Series · doi:10.1201/b12056-31 · Cited by 1,241
Fault Location on Power Networks
Saha, M. M., Iżykowski, J., & Rosołowski, E. (2009) · Power systems · doi:10.1007/978-1-84882-886-5 · Cited by 768
Analysis of Faulted Power Systems
Anderson, P. M. (2009) · Institute of Electrical and Electronics Engineers eBooks · doi:10.1109/9780470544129 · Cited by 586
Distribution System Modeling and Analysis
Kersting, W. H. (2001) · doi:10.1201/9781420041736 · Cited by 354
Comparison of impedance based fault location methods for power distribution systems
Mora-Flòrez, J., Meléndez, J., & Carrillo-Caicedo, G. (2008) · Electric Power Systems Research · doi:10.1016/j.epsr.2007.05.010 · Cited by 286
Extended Fault-Location Formulation for Power Distribution Systems
Salim, R. H., Resener, M., Filomena, A. D., Rezende Caino de Oliveira, K., & Bretas, A. S. (2009) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2008.2002977 · Cited by 240
Self-citationImproved Fault Location on Distribution Feeders Based on Matching During-Fault Voltage Sags
Pereira, R. A. F., da Silva, L. G. W., Kezunovic, M., & Mantovani, J. R. S. (2009) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2014480 · Cited by 159
Fault Location for Underground Power Cable Using Distributed Parameter Approach
Yang, X., Choi, M.-S., Lee, S., Ten, C., & Lim, S.-I. (2008) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.2002289 · Cited by 153
Metadata
- Authors
- Salim, R. H., Salim, K. C. O., & Bretas, A. S.
- Venue
- IET Generation, Transmission & Distribution
- Published
- 2011-04
- Volume
- 5
- Issue
- 4
- Pages
- 467-478
- ISSN
- 1751-8687 (ISSN-L)
- 1751-8695
- OpenAlex
- W2068952668
- Cited by
- 162
- References
- 17
- FWCI
- 17.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Further improvements on impedance-based fault location for power distribution systems. https://app.cochat.ai/papers/10.1049/iet-gtd.2010.0446
- The paper
- Salim, R. H., Salim, K. C. O., & Bretas, A. S. (2011). Further improvements on impedance-based fault location for power distribution systems. IET Generation, Transmission & Distribution. https://doi.org/10.1049/iet-gtd.2010.0446
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.