Discrimination and analysis of phytoplankton using a microfluidic cytometer
The DOI matches its Crossref record.
Abstract
Identification and analysis of phytoplankton is important for understanding the environmental parameters that are influenced by the oceans, including pollution and climate change. Phytoplanktons are studied at the single cell level using conventional light-field and fluorescence microscopy, but the technique is labour intensive. Flow cytometry enables rapid and quantitative measurements of single cells and is now used as an analytical tool in phytoplankton analysis. However, it has a number of drawbacks, including high cost and portability. We describe the fabrication of a microfluidic (lab-on-a-chip) device for high-speed analysis of single phytoplankton. The device measures fluorescence (at three wavelength ranges) and the electrical impedance of single particles. The system was tested using a mixture of three algae (Isochrysis Galbana, Rhodosorus m., Synechococcus sp.) and the results compared with predictions from theory and measurements using a commercial flow cytometer (BD FACSAria). It is shown that the microfluidic flow cytometer is able to distinguish and characterise these different taxa and that impedance spectroscopy enables measurement of phytoplankton biophysical properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Single-cell microfluidic impedance cytometry: a review
Sun, T., & Morgan, H. (2010) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0580-9 · Cited by 576
Self-citationA review of impedance measurements of whole cells
Xu, Y., Xie, X., Duan, Y., Wang, L., Cheng, Z., & Cheng, J. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.10.027 · Cited by 424
Toward the Integrated Marine Debris Observing System
Maximenko, N., Corradi, P., Law, K. L., Van Sebille, E., Garaba, S. P., Lampitt, R. S., Galgani, F., Martinez-Vicente, V., Goddijn-Murphy, L., Veiga, J. M., et al. (2019) · Frontiers in Marine Science · doi:10.3389/fmars.2019.00447 · Cited by 306
Self-citationRecent advances in microfluidic techniques for single-cell biophysical characterization
Zheng, Y., Nguyen, J., Wei, Y., & Sun, Y. (2013) · Lab on a Chip · doi:10.1039/c3lc50355k · Cited by 267
Microfluidics for Microalgal Biotechnology
Ozdalgic, B., Ustun, M., Dabbagh, S. R., Haznedaroglu, B. Z., Kiraz, A., & Tasoglu, S. (2021) · Biotechnology and Bioengineering · doi:10.1002/bit.27669 · Cited by 37
Metadata
- Authors
- Benazzi, G., Holmes, D., Sun, T., Mowlem, M. C., & Morgan, H.
- Venue
- IET Nanobiotechnology
- Published
- 2007-12-17
- Volume
- 1
- Issue
- 6
- Pages
- 94-101
- ISSN
- 1751-8741 (ISSN-L)
- 1751-875X
- OpenAlex
- W2170958398
- Cited by
- 83
- References
- 0
- FWCI
- 1.83
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Discrimination and analysis of phytoplankton using a microfluidic cytometer. https://app.cochat.ai/papers/10.1049/iet-nbt:20070020
- The paper
- Benazzi, G., Holmes, D., Sun, T., Mowlem, M. C., & Morgan, H. (2007). Discrimination and analysis of phytoplankton using a microfluidic cytometer. IET Nanobiotechnology. https://doi.org/10.1049/iet-nbt%3A20070020
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.