Evaluations of current control in weak grid case for grid‐connected LCL‐filtered inverter
Open accessThe DOI matches its Crossref record.
Abstract
For grid‐connected inverters, switching harmonics can be effectively attenuated through an LCL‐type filter. In order to suppress resonance and guarantee good performance, many strategies (e.g. active damping (AD), harmonic resonant control, repetitive control and grid feedforward) have been proposed. However, the wide variation of grid impedance value challenges system stability in practical applications. The aforementioned methods need to be investigated. This study evaluates the applicability of each part of the overall control in a weak grid case with the use of a stability criterion. It has been demonstrated that the feedback‐based AD control can work well in a wide range of grid conditions. However, the resonant and repetitive control methods meet constraints. The grid feedforward method brings in an extra positive feedback path, and consequently results in high harmonics or even instability. Finally, a recommendation for system design has been presented. Simulations and experiments have been provided to verify the analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Charging Infrastructure and Grid Integration for Electromobility
Rivera, S., Goetz, S. M., Kouro, S., Lehn, P. W., Pathmanathan, M., Bauer, P., & Mastromauro, R. A. (2023) · Proceedings of the IEEE · doi:10.1109/jproc.2022.3216362 · Cited by 233
Xu, J., Xie, S., & Tang, T. (2014) · IET Power Electronics · doi:10.1049/iet-pel.2013.0666 · Cited by 158
Self-citation
Metadata
- Authors
- Xu, J., Xie, S., & Tang, T.
- Venue
- IET Power Electronics
- Published
- 2013-02
- Volume
- 6
- Issue
- 2
- Pages
- 227-234
- ISSN
- 1755-4535 (ISSN-L)
- 1755-4543
- OpenAlex
- W1985061015
- Cited by
- 159
- References
- 0
- FWCI
- 19.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.