Improved control strategy with grid‐voltage feedforward for LCL‐filter‐based inverter connected to weak grid
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
In grid‐connected LCL‐filtered inverters, the dual‐loop current control is widely used. The LCL resonance is highly damped by proper feedback of the capacitor current. To suppress low‐frequency current harmonics, a grid‐voltage feedforward is commonly used. However, the system performance with such control is declined when connecting to a weak grid. Phase and gain margins are largely reduced while the proportional feedforward is used. The margins get worse and instability is aroused if the derivative feedforward is further implemented. Besides, a negative impact on the rejection of grid‐voltage‐induced harmonics is produced. To improve the control performance in the weak grid case, an adaptive control has been proposed. Adopting the estimated grid impedance, the signal for the grid‐voltage feedforward is modified and the controller is adjusted with an adaptive rule to maintain a good phase margin or a high bandwidth. Performances of the inverter with the typical and the proposed methods are compared. Simulation and experimental results have demonstrated that the grid‐connected LCL‐filtered inverter with the proposed method produced a high‐quality current while large grid impedance existed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impedance-Based Stability Criterion for Grid-Connected Inverters
Sun, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2136439 · Cited by 2,574
Design and Control of an LCL-Filter-Based Three-Phase Active Rectifier
Liserre, M., Blaabjerg, F., & Hansen, S. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853373 · Cited by 2,402
A new single-phase PLL structure based on second order generalized integrator
Ciobotaru, M., Teodorescu, R., & Blaabjerg, F. (2006) · 2006 37th IEEE Power Electronics Specialists Conference · doi:10.1109/pesc.2006.1711988 · Cited by 1,189
Liserre, M., Teodorescu, R., & Blaabjerg, F. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.861185 · Cited by 1,101
Evaluation of Current Controllers for Distributed Power Generation Systems
Timbus, A., Liserre, M., Teodorescu, R., Rodriguez, P., & Blaabjerg, F. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2012527 · Cited by 934
Dannehl, J., Wessels, C., & Fuchs, F. W. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2008774 · Cited by 747
Filter-Based Active Damping of Voltage Source Converters With $LCL$ Filter
Dannehl, J., Liserre, M., & Fuchs, F. W. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2081952 · Cited by 648
Regions of Active Damping Control for LCL Filters
Parker, S. G., McGrath, B. P., & Holmes, D. G. (2014) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2266892 · Cited by 624
A Digital Controlled PV-Inverter With Grid Impedance Estimation for ENS Detection
Asiminoaei, L., Teodorescu, R., Blaabjerg, F., & Borup, U. (2005) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.857506 · Cited by 285
Grid Impedance Estimation via Excitation of $LCL$-Filter Resonance
Liserre, M., Blaabjerg, F., & Teodorescu, R. (2007) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2007.904439 · Cited by 216
Evaluations of current control in weak grid case for grid‐connected LCL‐filtered inverter
Xu, J., Xie, S., & Tang, T. (2013) · IET Power Electronics · doi:10.1049/iet-pel.2012.0192 · Cited by 159
Self-citationMohamed, Y. A. I. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2161489 · Cited by 89
Cited by
Ravanji, M. H., Rathnayake, D. B., Mansour, M. Z., & Bahrani, B. (2023) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2023.3246566 · Cited by 47
Metadata
- Authors
- Xu, J., Xie, S., & Tang, T.
- Venue
- IET Power Electronics
- Published
- 2014-10
- Volume
- 7
- Issue
- 10
- Pages
- 2660-2671
- ISSN
- 1755-4535 (ISSN-L)
- 1755-4543
- OpenAlex
- W2082437557
- Cited by
- 158
- References
- 12
- FWCI
- 20.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.