CoChat

Improved control strategy with grid‐voltage feedforward for LCL‐filter‐based inverter connected to weak grid

Open access
Xu, Jinming, Xie, Shaojun, Tang, Ting · 2014 · IET Power Electronics
Cited by 158

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

In grid‐connected LCL‐filtered inverters, the dual‐loop current control is widely used. The LCL resonance is highly damped by proper feedback of the capacitor current. To suppress low‐frequency current harmonics, a grid‐voltage feedforward is commonly used. However, the system performance with such control is declined when connecting to a weak grid. Phase and gain margins are largely reduced while the proportional feedforward is used. The margins get worse and instability is aroused if the derivative feedforward is further implemented. Besides, a negative impact on the rejection of grid‐voltage‐induced harmonics is produced. To improve the control performance in the weak grid case, an adaptive control has been proposed. Adopting the estimated grid impedance, the signal for the grid‐voltage feedforward is modified and the controller is adjusted with an adaptive rule to maintain a good phase margin or a high bandwidth. Performances of the inverter with the typical and the proposed methods are compared. Simulation and experimental results have demonstrated that the grid‐connected LCL‐filtered inverter with the proposed method produced a high‐quality current while large grid impedance existed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1049/iet-pel.2013.0666

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 158

Metadata

Authors
Xu, J., Xie, S., & Tang, T.
Venue
IET Power Electronics
Published
2014-10
Volume
7
Issue
10
Pages
2660-2671
ISSN
  • 1755-4535 (ISSN-L)
  • 1755-4543
OpenAlex
W2082437557
Cited by
158
References
12
FWCI
20.47
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.