The DOI matches its Crossref record.
Integration of large-scale wind power and use of energy storage in the Netherlands' electricity supply
Abstract
The use of energy storage for increased operational flexibility is commonly regarded as a logical complement for systems with large amounts of wind power. The authors explore, the opportunities for energy storage for the integration of large-scale wind power into a future lay-out of the Dutch generation system, for which minimum-load problems are foreseen with high wind power penetrations. A central unit commitment and economic despatch model is extended with models for three large-scale energy storage technologies: pumped hydro accumulation storage (PAC), underground PAC and compressed air energy storage. Furthermore, an alternative solution is investigated, comprising the installation of heat boilers at selected combined heat and power locations (CHP) in order to increase the operational flexibility of these units. Results are shown for different wind power penetrations and scenarios. A cost–benefit analysis shows that the operation cost savings from energy storage increase with the amount of wind power installed. Taking into account the large investment costs, energy storage units are however unlikely to have a profitable exploitation. The installation of heat boilers at CHP locations is found to be more efficient and a promising solution for the integration of large-scale wind power in the Netherlands. A notable result is that for the Dutch system, the use of energy storage increases the system's overall CO2 emission levels because energy storage allows storing power from cheap coal plants for substitution of expensive gas during peak. Even though often proposed as a solution for wind power integration, energy storage in fact partly annuls CO2 emission savings by wind power.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Review of energy system flexibility measures to enable high levels of variable renewable electricity
Lund, P. D., Lindgren, J., Mikkola, J., & Salpakari, J. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.01.057 · Cited by 1,700
Pumped hydro energy storage system: a technological review
Rehman, S., Al-Hadhrami, L. M., & Alam, M. M. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.12.040 · Cited by 1,264
Holttinen, H., Meibom, P., Orths, A., Lange, B., O'Malley, M., Tande, J. O., Estanqueiro, A., Gomez, E., Söder, L., Strbac, G., et al. (2011) · Wind Energy · doi:10.1002/we.410 · Cited by 467
Hourly Coordination of Electric Vehicle Operation and Volatile Wind Power Generation in SCUC
Khodayar, M. E., Wu, L., & Shahidehpour, M. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2186642 · Cited by 392
Trends and challenges in the operation of pumped-storage hydropower plants
Pérez-Díaz, J. I., Chazarra, M., García-González, J., Cavazzini, G., & Stoppato, A. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.01.029 · Cited by 328
Mathiesen, B. V., & Lund, H. (2009) · IET Renewable Power Generation · doi:10.1049/iet-rpg:20080049 · Cited by 288
Integration of Renewable Energy into Present and Future Energy Systems
Sims, R., Mercado, P., Krewitt, W., Bhuyan, G., Flynn, D., Holttinen, H., Jannuzzi, G., Khennas, S., Liu, Y., Nilsson, L. J., et al. (2011) · Renewable Energy Sources and Climate Change Mitigation · doi:10.1017/cbo9781139151153.012 · Cited by 98
Metadata
- Authors
- Ummels, B. C., Pelgrum, E., & Kling, W. L.
- Venue
- IET Renewable Power Generation
- Published
- 2008-03-10
- Volume
- 2
- Issue
- 1
- Pages
- 34-46
- ISSN
- 1752-1416 (ISSN-L)
- 1752-1424
- OpenAlex
- W2159033174
- Cited by
- 178
- References
- 0
- FWCI
- 13.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.