Energy management system for residential buildings based on fuzzy logic: design and implementation in smart‐meter
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Advances in distributed generation and increased contribution of renewable energy source (RES) require development of smart grid technologies. Smart metering systems, as a part of smart grid technologies, in cooperation with modern buildings equipped with building management system allows for improvement of energy efficiency. It is possible to partially cover the power demand of a building from the local RESs. However, in order to ensure maximum added value, energy management system (EMS) is essential. This article presents the project and practical implementation of an EMS implemented in smart‐meter. The designed system is based on an original algorithm using fuzzy logic. The rule base was created in FCL language and the implementation was carried out in C++ with the object‐oriented programming (OOP). For the efficiency rating indicator, peak‐to‐average ratio (PAR) was selected. This ratio depending on the daily load profile decreased within a range from 15 to 54%, and the average value was 30%. The proposed energy management algorithm helps to reduce energy consumption at peak demand by 34%, with the total reduction of energy consumption during the day of 7%. The described solution demonstrates a potential for real implementation and was tested in hardware.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“ANN-based predictors and Fuzzy Logic Controllers often achieve longer stable runs-as long as several months-since they rely on pre-trained or rule-based logic that does not require continuous exploration [130,132,147].”
From Machine Learning for Energy Management in Buildings: A Systematic Review on Real-World Applications (2025) · cites this paper as [147]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Big data analytics for dynamic energy management in smart grids
Diamantoulakis, P. D., Kapinas, V. M., & Karagiannidis, G. K. (2015) · Big Data Research · doi:10.1016/j.bdr.2015.03.003 · Cited by 349
Research works printed but not linked: 41
- 10.1109/SURV.2012.021312.00034 · DOI · Paper page
- 10.1016/j.rser.2015.12.114 · DOI · Paper page
- 10.12736/issn.2300-3022.2014211 · doi:10.12736/issn.2300-3022.2014211
- MakoninS.PopowichF.GillB.: ‘The cognitive power meter: looking beyond the smart meter’.2013 26th Annual IEEE Canadian Conf. Electrical and Computer Engineering (CCECE) Regina Canada 2013 pp.1–5 · DOI
- KnollT.M.: ‘A combined CAPEX and OPEX cost model for LTE networks’.2014 16th Int. IEEE Telecommunications Network Strategy and Planning Symp. (Networks) Funchal Portugal 2014 pp.1–6 · doi:10.1109/netwks.2014.6958531
- 10.1016/j.procs.2014.05.537 · doi:10.1016/j.procs.2014.05.537
- CavoukianA.KursaweK.: ‘Implementing privacy by design: the smart meter case’.2012 IEEE Int. Conf. Smart Grid Engineering (SGE) Oshawa Canada 2012 pp.1–8 · doi:10.1109/sge.2012.6463977
- 10.1016/j.ssresearch.2014.12.003 · DOI
- 10.1109/TSG.2014.2343611 · doi:10.1109/tsg.2014.2343611
- 10.1109/JSYST.2013.2291943 · DOI
- HurtadoL.A.NguyenP.H.KlingW.L.: ‘Agent‐based control for building energy management in the smart grid framework’.2014 IEEE PES Innovative Smart Grid Technologies Conf. Europe (ISGT‐Europe) Istanbul Turkey 2014 pp.1–6 · DOI
- SianakiO.A.MasoumM.A.S.: ‘A fuzzy TOPSIS approach for home energy management in smart grid with considering householders’ preferences’.2013 IEEE PES Innovative Smart Grid Technologies (ISGT) Washington DC USA 2013 pp.1–6 · DOI
- 10.1109/TSG.2013.2289922 · doi:10.1109/tsg.2013.2289922
- 10.1109/TSG.2014.2304961 · DOI
- 10.1049/joe.2017.0523 · DOI
- 10.1109/TSG.2012.2225453 · DOI
- 10.1016/j.rser.2015.10.117 · DOI · Paper page
- 10.1109/MPE.2011.940264 · doi:10.1109/mpe.2011.940264
- 10.1109/TPWRS.2014.2298894 · DOI
- 10.1109/JSAC.2013.130710 · DOI · Paper page
- TokudaK.MatsumotoS.NakamuraM.: ‘Implementing a mobile application for spontaneous peak shaving of home electricity’.2013 IEEE 9th Int. Conf. on Wireless and Mobile Computing Networking and Communications (WiMob) Lyon France 2013 pp.273–278 · DOI
- Borkowski P., 2010, The effects of BMS on building energy efficiency, Prz Elektrotechniczny, 86, 57
- 10.1016/j.rser.2015.04.037 · DOI · Paper page
- 10.1049/iet-gtd.2018.5791 · DOI
- ChangH.H.LinC.L.LeeJ.K.: ‘Load identification in nonintrusive load monitoring using steady‐state and turn‐on transient energy algorithms’.2010 14th Int. Conf. Computer Supported Cooperative Work in Design (CSCWD) Shanghai China 2010 pp.27–32 · DOI
- 10.1109/JSYST.2013.2260700 · DOI · Paper page
- 10.1109/JSAC.2013.130715 · DOI · Paper page
- TerzicI.ZoitlA.FavreB.et al.: ‘A survey of distributed intelligence in automation in European industry research and market’.IEEE Int. Conf. on Emerging Technologies and Factory Automation 2008. ETFA 2008 Hamburg Germany 2008 pp.221–228 · doi:10.1109/etfa.2008.4638396
- 10.1109/TIE.2014.2361486 · DOI · Paper page
- 10.1016/j.energy.2013.09.052 · doi:10.1016/j.energy.2013.09.052
- 10.1016/j.enpol.2012.01.051 · DOI
- 10.1109/TFUZZ.2015.2394781 · doi:10.1109/tfuzz.2015.2394781
- 10.1049/iet-gtd.2016.1615 · DOI
- 10.1002/0471698504 · DOI · Paper page
- 10.1142/p976 · doi:10.1142/p976
- RohmanuddinM.TheH.‐L.AhmadA.S.et al.: ‘Simplifying fuzzy rule base of multiple input multiple output systems by constructing multilayer fuzzy controller’.Smc 2000 conf. proc. Nashville USA 2000 vol.5 pp.3728–3733 · doi:10.1109/icsmc.2000.886590
- MiaoZ.N.XiaS.F.XuY.: ‘Fuzzy controller using multiple rule bases’.Proc. 2004 Int. Conf. on Machine Learning and Cybernetics (IEEE Cat. No.04EX826) Shanghai China 2004 vol.2 pp.1093–1098 · doi:10.1109/icmlc.2004.1382352
- VignolaF.: ‘Variability of solar radiation data over short time intervals’. Available athttps://pdfs.semanticscholar.org/ad5b/02eae64bb287d4a0fbab5cc05c243039a11e.pdf
- 10.1109/91.544304 · DOI
- 10.1080/18756891.2013.818190 · DOI · Paper page
- ChoiI.H.LeeJ.H.HongS.H.: ‘Implementation and evaluation of the apparatus for intelligent energy management to apply to the smart grid at home’.2011 IEEE Instrumentation and Measurement Technology Conf. (I2MTC) Binjiang China 2011 pp.1–5 · DOI
Cited by
Machine Learning for Energy Management in Buildings: A Systematic Review on Real-World Applications
Michailidis, P., Minelli, F., Michailidis, I., Kurucan, M., Coban, H. H., & Kosmatopoulos, E. (2025) · Energies · doi:10.3390/en19010219 · Cited by 26
Human-in-the-Loop AI for HVAC Management Enhancing Comfort and Energy Efficiency
Liang, X., de Nijs, F., Say, B., & Wang, H. (2025) · Proceedings of the 16th ACM International Conference on Future and Sustainable Energy Systems · doi:10.1145/3679240.3734587 · Cited by 14
“These systems autonomously reduce heating or cooling during unoc-cupied periods and increase output as needed to maintain set-points [12, 17, 24, 27].”
Metadata
- Authors
- Chojecki, A., Rodak, M., Ambroziak, A., & Borkowski, P.
- Affiliations
- Faculty of Electrical, Electronic, Computer and Control Engineering, Department of Electrical Apparatus Lodz University of Technology B.Stefanowskiego 18/22 90‐537 Lodz Poland
- Venue
- IET Smart Grid
- Published
- 2020-02-26
- Volume
- 3
- Issue
- 2
- Pages
- 254-266
- ISSN
- 2515-2947
- Cited by
- 33
- References
- 1
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Energy management system for residential buildings based on fuzzy logic: design and implementation in smart‐meter. https://app.cochat.ai/papers/10.1049/iet-stg.2019.0005
- The paper
- Chojecki, A., Rodak, M., Ambroziak, A., & Borkowski, P. (2020). Energy management system for residential buildings based on fuzzy logic: design and implementation in smart‐meter. IET Smart Grid. https://doi.org/10.1049/iet-stg.2019.0005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.