The DOI matches its Crossref record.
Vibration and current monitoring for detecting airgap eccentricity in large induction motors
Abstract
The paper reports on a study carried out to detect airgap eccentricity in large 3-phase induction motors. The philosophy of using a unified online monitoring strategy is presented and the reasons for selecting line current and frame vibration as the monitored parameters are discussed. A theoretical analysis is presented which predicts the presence of unique signature patterns in the current and vibration spectra which are only characteristic of eccentricity. The theoretical predictions are verified by experimental results from a special fault producing test rig and on-site tests in a power station.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Condition Monitoring and Fault Diagnosis of Electrical Motors—A Review
Nandi, S., Toliyat, H. A., & Li, X. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.847955 · Cited by 2,382
A review of induction motors signature analysis as a medium for faults detection
El Hachemi Benbouzid, M. (2000) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.873206 · Cited by 1,602
Current Signature Analysis to Detect Induction Motor Faults
Thomson, W. T., & Fenger, M. (2001) · IEEE Industry Applications Magazine · doi:10.1109/2943.930988 · Cited by 1,139
Self-citationFundamentals of Noise and Vibration Analysis for Engineers
Norton, M. P., & Karczub, D. G. (2003) · Cambridge University Press eBooks · doi:10.1017/cbo9781139163927 · Cited by 709
A Survey of Condition Monitoring and Protection Methods for Medium-Voltage Induction Motors
Zhang, P., Du, Y., Habetler, T. G., & Lu, B. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2010.2090839 · Cited by 706
A Review of Stator Fault Monitoring Techniques of Induction Motors
Siddique, A., Yadava, G. S., & Singh, B. (2005) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.837304 · Cited by 591
Models for Bearing Damage Detection in Induction Motors Using Stator Current Monitoring
Blodt, M., Granjon, P., Raison, B., & Rostaing, G. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.917108 · Cited by 568
Condition monitoring and fault diagnosis of electrical machines-a review
Nandi, S., & Toliyat, H. A. (2003) · Conference Record of the 1999 IEEE Industry Applications Conference. Thirty-Forth IAS Annual Meeting (Cat. No.99CH36370) · doi:10.1109/ias.1999.799956 · Cited by 531
A survey of condition monitoring and protection methods for medium voltage induction motors
Zhang, P., Du, Y., Habetler, T. G., & Lu, B. (2009) · 2009 IEEE Energy Conversion Congress and Exposition · doi:10.1109/ecce.2009.5316083 · Cited by 524
Fault Detection in Induction Machines Using Power Spectral Density in Wavelet Decomposition
Cusid�Cusido, J., Romeral, L., Ortega, J. A., Rosero, J. A., & Garc�aGarcia Espinosa, A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.911960 · Cited by 512
Dorrell, D. G., Thomson, W. T., & Roach, S. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.567073 · Cited by 450
Self-citationBenbouzid, M. E. H., Vieira, M., & Theys, C. (1999) · IEEE Transactions on Power Electronics · doi:10.1109/63.737588 · Cited by 378
Dorrell, D. G., Thomson, W. T., & Roach, S. (2002) · IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting · doi:10.1109/ias.1995.530349 · Cited by 367
Self-citationNandi, S., Ahmed, S., & Toliyat, H. A. (2001) · IEEE Transactions on Energy Conversion · doi:10.1109/60.937205 · Cited by 340
Nandi, S., Ahmed, S., & Toliyat, H. (2001) · IEEE Power Engineering Review · doi:10.1109/mper.2001.4311622 · Cited by 298
From Corrective to Predictive Maintenance—A Review of Maintenance Approaches for the Power Industry
Molęda, M., Małysiak-Mrozek, B., Ding, W., Sunderam, V., & Mrozek, D. (2023) · Sensors · doi:10.3390/s23135970 · Cited by 288
Effects of time-varying loads on rotor fault detection in induction machines
Schoen, R. R., & Habetler, T. G. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.395302 · Cited by 272
Al-Nuaim, N. A., & Toliyat, H. (1998) · IEEE Transactions on Energy Conversion · doi:10.1109/60.678979 · Cited by 269
Mechanical Load Fault Detection in Induction Motors by Stator Current Time-Frequency Analysis
Blodt, M., Chabert, M., Regnier, J., & Faucher, J. (2006) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2006.882631 · Cited by 267
Riera-Guasp, M., Antonino-Daviu, J. A., Pineda-Sanchez, M., Puche-Panadero, R., & Perez-Cruz, J. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2004378 · Cited by 267
Rajagopalan, S., Roux, W. L., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.904183 · Cited by 164
Park, Y., Fernandez, D., Lee, S. B., Hyun, D., Jeong, M., Kommuri, S. K., Cho, C., Diaz Reigosa, D., & Briz, F. (2019) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2018.2886772 · Cited by 116
Climente-Alarcon, V., Antonino-Daviu, J. A., Riera-Guasp, M., Puche-Panadero, R., & Escobar, L. (2012) · Electric Power Systems Research · doi:10.1016/j.epsr.2012.05.001 · Cited by 78
Karami, M., Mariun, N., Rezazadeh Mehrjou, M., Ab Kadir, M. Z. A., Misron, N., & Mohd Radzi, M. A. (2014) · Mathematical Problems in Engineering · doi:10.1155/2014/132647 · Cited by 31
Metadata
- Authors
- Cameron, J. R., Thomson, W. T., & Dow, A. B.
- Venue
- IEE Proceedings B Electric Power Applications
- Published
- 1986
- Volume
- 133
- Issue
- 3
- Pages
- 155
- ISSN
- 0143-7038 (ISSN-L)
- OpenAlex
- W2138461713
- Cited by
- 512
- References
- 0
- FWCI
- 4.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.