Accurate fault location technique for power transmission lines
Abstract
The paper describes a very accurate fault location technique which uses post-fault voltage and current derived at both line ends. Fault location is independent of fault resistance and the method does not require any knowledge of source impedance. It maintains high accuracy for untransposed lines and no fault type identification is required. The paper presents the theory of the technique and the results of simulation studies to determine its performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of a New Type Fault Locator Using the One-Terminal Voltage and Current Data
Takagi, T., Yamakoshi, Y., Yamaura, M., Kondow, R., & Matsushima, T. (1982) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1982.317615 · Cited by 635
Cited by
Smart Fault Location for Smart Grids
Kezunovic, M. (2011) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2118774 · Cited by 380
A new fault location technique for two- and three-terminal lines
Girgis, A. A., Hart, D. G., & Peterson, W. L. (1992) · IEEE Transactions on Power Delivery · doi:10.1109/61.108895 · Cited by 374
Metadata
- Authors
- Johns, A. T., & Jamali, S.
- Venue
- IEE Proceedings C Generation, Transmission and Distribution
- Published
- 1990
- Volume
- 137
- Issue
- 6
- Pages
- 395
- ISSN
- 0143-7046 (ISSN-L)
- OpenAlex
- W2089339315
- Cited by
- 232
- References
- 1
- FWCI
- 1.63
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.