Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 248

The DOI matches its Crossref record.

Robust load-frequency controller design for power systems

Wang, Y., Zhou, R., Wen, C. · 1993 · IEE Proceedings C Generation, Transmission and Distribution

Abstract

A robust controller, based on the Riccati-equation approach, is proposed for power system load-frequency control. Only the bounds of the system parameters are required to design the robust load-frequency controller. The proposed robust controller is simple, effective and can ensure that the overall system is asymptotically stable for all admissable uncertainties. Simulation results show that, for the example system, the proposed robust load-frequency controller can achieve good performance even in the presence of generation rate constraint.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1049/ip-c.1993.0003

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 248

Metadata

Authors
Wang, Y., Zhou, R., & Wen, C.
Venue
IEE Proceedings C Generation, Transmission and Distribution
Published
1993
Volume
140
Issue
1
Pages
11
ISSN
0143-7046 (ISSN-L)
OpenAlex
W2063358594
Cited by
248
References
0
FWCI
1.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Robust load-frequency controller design for power systems. https://app.cochat.ai/papers/10.1049/ip-c.1993.0003
The paper
Wang, Y., Zhou, R., & Wen, C. (1993). Robust load-frequency controller design for power systems. IEE Proceedings C Generation, Transmission and Distribution. https://doi.org/10.1049/ip-c.1993.0003

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.