The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Single-phase half-bridge converter topology for power quality compensation
Abstract
A high power factor half-bridge rectifier with neutral point switch clamped scheme is proposed. Three power switches are employed in the proposed rectifier. Two PWM control schemes are used to draw a sinusoidal line current with low current distortion. The control signals of the power switches are derived from the DC link voltage balance compensator, line current controller and DC link voltage regulator. The hysteresis current control scheme is employed to track the line current command. The proposed control scheme and the circuit configuration can be applied to the active power filter to eliminate the harmonic currents and compensate the reactive power generated from the nonlinear load. Analytical and experimental results are included to illustrate the validity and effectiveness of the proposed control scheme.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Akagi, H., Kanazawa, Y., & Nabae, A. (1984) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1984.4504460 · Cited by 3,379
Nonlinear Control Systems: An Introduction
(1985) · Springer eBooks · doi:10.1007/bfb0006368 · Cited by 1,864
Application Issues of Active Power Filters
Peng, F. Z. (1998) · IEEE Industry Applications Magazine · doi:10.1109/2943.715502 · Cited by 495
A PWM AC-to-DC converter with fixed switching frequency
Wu, R. K., Dewan, S. B., & SLEMON, G. R. (1990) · IEEE Transactions on Industry Applications · doi:10.1109/28.60060 · Cited by 398
A topology survey of single-stage power factor corrector with a boost type input-current-shaper
Qiao, C., & Smedley, K. M. (2001) · IEEE Transactions on Power Electronics · doi:10.1109/63.923768 · Cited by 389
A high-performance single-phase rectifier with input power factor correction
Martinez, R., & Enjeti, P. N. (1996) · IEEE Transactions on Power Electronics · doi:10.1109/63.486181 · Cited by 279
Current-forced single-phase reversible rectifier
Boys, J. T., & Green, A. W. (1989) · IEE Proceedings B Electric Power Applications · doi:10.1049/ip-b.1989.0028 · Cited by 236
Soft-switching PWM three-level converters
Ruan, X., Zhou, L., & Yan, Y. (2001) · IEEE Transactions on Power Electronics · doi:10.1109/63.949494 · Cited by 185
Design and Performance Of Active Power Filters
Thomas, T., Haddad, K. A., Joós, G., et al. (1998) · IEEE Industry Applications Magazine · doi:10.1109/2943.715505 · Cited by 98
Novel full bridge semicontrolled switch mode rectifier
Manias, S. N. (1991) · IEE Proceedings B Electric Power Applications · doi:10.1049/ip-b.1991.0030 · Cited by 94
Space vector modulated, zero-voltage transition three-phase to DC bidirectional converter
Cuadros, C., Borojevic, D., Gataric, S., et al. (2002) · PESC record · doi:10.1109/pesc.1994.349755 · Cited by 80
Three-phase switch mode rectifier with hysteresis current control
Dawande, M. S., Kanetkar, V. R., & Dubey, G. K. (1996) · IEEE Transactions on Power Electronics · doi:10.1109/63.491640 · Cited by 80
Adaptive directive neural network controlfor three-phase AC/DC PWM converter
Cheng, K. W. E., Wang, H. Y., & Sutanto, D. (2001) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20010564 · Cited by 20
Proceedings of IEEE Power Electronics Specialist Conference - PESC '93
(1993) · PESC record · doi:10.1109/pesc.1993.471917 · Cited by 12
Transformations for a class of nonlinear time-varying multivariable systems and their applications
Tsai, J. S. H., & Chiang, H. (1992) · IMA Journal of Mathematical Control and Information · doi:10.1093/imamci/9.1.61 · Cited by 8
Flagged first, then by citations
Research works printed but not linked: 2
- Bhim, 1996, Proceedings of IEEE Power Electronics Specialists Conference, PESC'96, 677
- Tsai, 1992, 9, 61
Cited by
Sorted by citations
A Review of Bidirectional On-Board Chargers for Electric Vehicles
Yuan, J., Dorn-Gomba, L., Callegaro, A. D., Reimers, J., & Emadi, A. (2021) · IEEE Access · doi:10.1109/access.2021.3069448 · Cited by 390
Single-phase half-bridge rectifier with power factor correction
Lin, B. R., & Yang, T. Y. (2004) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20040237 · Cited by 19
Self-citation
Metadata
- Authors
- Lin, B.-R., & Hung, T.-L.
- Affiliations
- National Yunlin University of Science and Technology (TW)
- Venue
- IEE Proceedings - Electric Power Applications
- Published
- 2002-09-10
- Volume
- 149
- Issue
- 5
- Pages
- 351-359
- ISSN
- 1350-2352 (ISSN-L)
- 1359-7043
- OpenAlex
- W2037750119
- Cited by
- 24
- References
- 15
- Citations by year
- 2023: 1 · 2022: 2 · 2021: 1 · 2016: 1 · 2015: 2 · 2013: 2 · 2012: 1
- FWCI
- 2.45
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEE Proceedings - Electric Power Applications (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Keywords
- half-bridge rectifier, power factor correction, active power filter, harmonic current compensation, reactive power compensation, hysteresis current control, PWM control, nonlinear loads, single-phase converter
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review