The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Bi-directional single-phase half-bridge rectifier for power quality compensation
Abstract
A single-phase half-bridge rectifier with a capacitor clamped scheme is proposed. Four power switches and one flying capacitor are employed in the proposed rectifier. Bipolar and unipolar PWM control schemes are used to perform power factor correction and achieve low total harmonic distortion of line current. A neutral point voltage balance compensator, hysteresis current controller and DC link voltage regulator are used to balance neutral point voltage, to track line current command, and to maintain the constant DC bus voltage. The proposed control scheme and the circuit configuration can also perform a shunt active power filter operation to eliminate the harmonic currents and compensate the reactive power generated from the nonlinear load. Analytical and experimental results are presented to illustrate the validity and effectiveness of the proposed control scheme.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
A New Neutral-Point-Clamped PWM Inverter
Nabae, A., Takahashi, I., & Akagi, H. (1981) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1981.4503992 · Cited by 5,151
Akagi, H., Kanazawa, Y., & Nabae, A. (1984) · IEEE Transactions on Industry Applications · doi:10.1109/tia.1984.4504460 · Cited by 3,379
Multilevel converters-a new breed of power converters
Lai, J., & Peng, F. Z. (2002) · Conference record · doi:10.1109/ias.1995.530601 · Cited by 2,667
Multilevel converters-a new breed of power converters
Lai, J., & Peng, F. Z. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.502161 · Cited by 2,608
A PWM AC-to-DC converter with fixed switching frequency
Wu, R. K., Dewan, S. B., & SLEMON, G. R. (1990) · IEEE Transactions on Industry Applications · doi:10.1109/28.60060 · Cited by 398
Comparison of multilevel inverters for static VAr compensation
Hochgraf, C. G., Lasseter, R. H., Divan, D. M., et al. (2002) · Conference record · doi:10.1109/ias.1994.377528 · Cited by 354
Current-forced single-phase reversible rectifier
Boys, J. T., & Green, A. W. (1989) · IEE Proceedings B Electric Power Applications · doi:10.1049/ip-b.1989.0028 · Cited by 236
The design and implementation of a three-phase active power filter based on sliding mode control
Saetieo, S., Devaraj, R., & Torrey, D. A. (1995) · IEEE Transactions on Industry Applications · doi:10.1109/28.464511 · Cited by 166
Lin, B., & Wu, D.-P. (1998) · IEEE Transactions on Aerospace and Electronic Systems · doi:10.1109/7.670349 · Cited by 37
Self-citationImplementation of a three-level rectifier for power factor correction
Lin, B., Hou, Y.-L., & Chiang, H. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.867678 · Cited by 27
Self-citationStandby power supply with active power filter ability using digital controller
Choi, J., Park, G., & Dewan, S. B. (2002) · IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.1995.469031 · Cited by 26
Proceedings of IEEE Applied Power Electronics Conference APEC '93
(1993) · IEEE Applied Power Electronics Conference and Exposition (APEC) · doi:10.1109/apec.1993.290659 · Cited by 11
A DSP based active power filter for line interactive UPS
Qin, Y., & Du, S. (2002) · Proceedings of the Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.1995.483845 · Cited by 8
Flagged first, then by citations
Research works printed but not linked: 8
- Brkovic, 1992, Proceedings of IEEE International Telecommunications energy Conference, (INTELEC), 532
- Draou, 1994, 141, 275
- Erickson, 1990, Proceedings of IEEE Applied power electronics Conference (APEC), 792
- Watanabe, 1993, 8, 697
- Siares, 1997, Proceedings of European Power electronics and applications Conference (EPE), 4.804
- Stanislaw, 1997, Proceedings of the European power electronics and applications Conference (EPE), 4.831
- Isidori, A.: ‘Nonlinear control systems: an introduction’, 2nd(Springer-Verlag, London 1991)
- Tsai, 1992, 9, 61
Cited by
Sorted by citations
A Review of Bidirectional On-Board Chargers for Electric Vehicles
Yuan, J., Dorn-Gomba, L., Callegaro, A. D., Reimers, J., & Emadi, A. (2021) · IEEE Access · doi:10.1109/access.2021.3069448 · Cited by 390
“A single-phase multilevel converters, such as three-level NPC [88], T-type [89] and six-level flying capacitor topology [90]–[94], enable device voltage stress reductions and power level increase.”
MethodSingle-phase half-bridge rectifier with power factor correction
Lin, B. R., & Yang, T. Y. (2004) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20040237 · Cited by 19
Self-citation
Metadata
- Authors
- Lin, B. R., Hung, T. L., & Huang, C. H.
- Affiliations
- National Yunlin University of Science and Technology (TW)
- ORCID
- Venue
- IEE Proceedings - Electric Power Applications
- Published
- 2003-07-08
- Volume
- 150
- Issue
- 4
- Pages
- 397-406
- ISSN
- 1350-2352 (ISSN-L)
- 1359-7043
- OpenAlex
- W1972408375
- Cited by
- 22
- References
- 13
- Citations by year
- 2025: 1 · 2023: 2 · 2022: 2 · 2021: 3 · 2019: 1 · 2017: 1 · 2016: 2 · 2015: 1 · 2013: 2 · 2012: 1
- FWCI
- 0.67
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEE Proceedings - Electric Power Applications (publishedVersion)
- Funders
- National Science Council
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Keywords
- flying capacitor, power factor correction, total harmonic distortion reduction, neutral-point voltage balancing, hysteresis current control, DC bus voltage regulation, shunt active power filter, reactive power compensation, nonlinear loads, harmonic current suppression
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review