The paper discusses the effect of single turn short-circuits in the windings of fault tolerant permanent magnet machines. It is shown that previously recognised methods for dealing with shorted turns do not work for larger bar-wound machines, and a new method for protecting the windings against single turn faults is therefore proposed. The new method depends on rapid detection of the fault and injection of a current (of appropriate magnitude and phase) into the faulted winding. The paper gives a theoretical analysis supported by finite element simulations of the fault conditions and illustrates these with a case study taken from the aerospace industry.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1049/ip-epa:20040686

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 43

Metadata

Authors
Mitcham, A. J., Antonopoulos, G., & Cullen, J. J. A.
Venue
IEE Proceedings - Electric Power Applications
Published
2004-11-07
Volume
151
Issue
6
Pages
651-657
ISSN
  • 1350-2352 (ISSN-L)
  • 1359-7043
OpenAlex
W2080207197
Cited by
43
References
1
FWCI
0.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.