The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Maximising penetration of wind generation in existing distribution networks
Abstract
Connections of embedded wind generation (EWG) in the rural distribution system are susceptible to voltage rise. Current operating policy, based on the passive operation of the distribution network, limits the capacity of connected generation based on extreme conditions of minimum load and maximum generation. It is demonstrated that an active distribution network will allow considerably greater penetration of EWG. Three alternative control strategies are evaluated to increase the penetration level of EWG: EWG generation curtailment during low demand; reactive power management using a reactive compensator; and area-based OLTC co-ordinated voltage control. The application of these schemes is illustrated on a rurally connected 11 kV wind farm in a realistic 265-node generic distribution system model. Advanced optimal power flow is used to quantify the benefits of alternative control schemes for various EWG penetration levels. The impact of these schemes on network losses is also assessed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Embedded Generation (Power & Energy Ser. 31)
Jenkins, N., Allan, R. N., Crossley, P. A., Kirschen, D., & Štrbac, G. (2000) · Cited by 253
Electricity Distribution Network Design
Taylor, A. V. (1990) · IEE Review · doi:10.1049/ir:19900064 · Cited by 247
Cited by
Assessment of Energy Distribution Losses for Increasing Penetration of Distributed Generation
MendezQuezada, V. H., RivierAbbad, J., & GomezSanRoman, T. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.873115 · Cited by 616
Distributed Reactive Power Generation Control for Voltage Rise Mitigation in Distribution Networks
Carvalho, P. M. S., Correia, P. F., & Ferreira, L. A. F. (2008) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.919203 · Cited by 607
Centralized and Distributed Voltage Control: Impact on Distributed Generation Penetration
Vovos, P. N., Kiprakis, A. E., Wallace, A. R., & Harrison, G. P. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.888982 · Cited by 545
Liu, X., Aichhorn, A., Liu, L., & Li, H. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2177501 · Cited by 486
Optimal Allocation of Embedded Generation on Distribution Networks
Keane, A., & O'Malley, M. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.852115 · Cited by 478
Keane, A., Ochoa, L. F., Borges, C. L. T., Ault, G. W., Alarcon-Rodriguez, A. D., Currie, R. A. F., Pilo, F., Dent, C., & Harrison, G. P. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2214406 · Cited by 429
Distribution Network Capacity Assessment: Variable DG and Active Networks
Ochoa, L. F., Dent, C. J., & Harrison, G. P. (2010) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2031223 · Cited by 400
Capitanescu, F., Ochoa, L. F., Margossian, H., & Hatziargyriou, N. D. (2015) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2320895 · Cited by 384
Mahmud, N., & Zahedi, A. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.06.030 · Cited by 377
Dynamic Optimal Power Flow for Active Distribution Networks
Gill, S., Kockar, I., & Ault, G. W. (2014) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2279263 · Cited by 334
Active Management of Low-Voltage Networks for Mitigating Overvoltages Due to Photovoltaic Units
Olivier, F., Aristidou, P., Ernst, D., & Van Cutsem, T. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2410171 · Cited by 328
Metadata
- Authors
- Liew, S. N., & Strbac, G.
- Venue
- IEE Proceedings - Generation, Transmission and Distribution
- Published
- 2002
- Volume
- 149
- Issue
- 3
- Pages
- 256
- ISSN
- 1350-2360 (ISSN-L)
- OpenAlex
- W2064055853
- Cited by
- 277
- References
- 3
- FWCI
- 5.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.