Engineering challenges of BioNEMS: the integration of microfluidics, micro- and nanodevices, models and external control for systems biology
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
Systems biology, i.e. quantitative, postgenomic, postproteomic, dynamic, multiscale physiology, addresses in an integrative, quantitative manner the shockwave of genetic and proteomic information using computer models that may eventually have 10(6) dynamic variables with non-linear interactions. Historically, single biological measurements are made over minutes, suggesting the challenge of specifying 10(6) model parameters. Except for fluorescence and micro-electrode recordings, most cellular measurements have inadequate bandwidth to discern the time course of critical intracellular biochemical events. Micro-array expression profiles of thousands of genes cannot determine quantitative dynamic cellular signalling and metabolic variables. Major gaps must be bridged between the computational vision and experimental reality. The analysis of cellular signalling dynamics and control requires, first, micro- and nano-instruments that measure simultaneously multiple extracellular and intracellular variables with sufficient bandwidth; secondly, the ability to open existing internal control and signalling loops; thirdly, external BioMEMS micro-actuators that provide high bandwidth feedback and externally addressable intracellular nano-actuators; and, fourthly, real-time, closed-loop, single-cell control algorithms. The unravelling of the nested and coupled nature of cellular control loops requires simultaneous recording of multiple single-cell signatures. Externally controlled nano-actuators, needed to effect changes in the biochemical, mechanical and electrical environment both outside and inside the cell, will provide a major impetus for nanoscience.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computational systems biology.
Kitano, H. (2002) · Nature · doi:10.1038/nature01254 · Cited by 2,209
A N EW A PPROACH TO D ECODING L IFE : Systems Biology
Ideker, T., Galitski, T., & Hood, L. (2001) · Annual Review of Genomics and Human Genetics · doi:10.1146/annurev.genom.2.1.343 · Cited by 1,664
Systems Biology and New Technologies Enable Predictive and Preventative Medicine
Hood, L., Heath, J. R., Phelps, M. E., & Lin, B. (2004) · Science · doi:10.1126/science.1104635 · Cited by 1,108
Schuster, S., Fell, D. A., & Dandekar, T. (2000) · Nature Biotechnology · doi:10.1038/73786 · Cited by 947
Dynamic flux balance analysis of diauxic growth in Escherichia coli
Mahadevan, R., Edwards, J. S., & Doyle, F. J. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)73903-9 · Cited by 945
Cell Fates as High-Dimensional Attractor States of a Complex Gene Regulatory Network
Huang, S., Eichler, G., Bar-Yam, Y., & Ingber, D. E. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.128701 · Cited by 775
Interlinked Fast and Slow Positive Feedback Loops Drive Reliable Cell Decisions
Brandman, O., Ferrell, J. E., Li, R., & Meyer, T. (2005) · Science · doi:10.1126/science.1113834 · Cited by 466
High-throughput and ultra-high-throughput screening: solution- and cell-based approaches
Sundberg, S. (2000) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(99)00051-8 · Cited by 455
Cited by
Automated reverse engineering of nonlinear dynamical systems
Bongard, J., & Lipson, H. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609476104 · Cited by 792
Nanovehicular Intracellular Delivery Systems
Prokop, A., & Davidson, J. M. (2008) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.21270 · Cited by 363
Self-citationOrgans-on-chips: breaking the in vitro impasse
Meer, A. D. V. D., & Berg, A. V. D. (2012) · Integrative Biology · doi:10.1039/c2ib00176d · Cited by 314
Scaling and systems biology for integrating multiple organs-on-a-chip
Wikswo, J. P., Curtis, E. L., Eagleton, Z. E., Evans, B. C., Kole, A., Hofmeister, L. H., & Matloff, W. J. (2013) · Lab on a Chip · doi:10.1039/c3lc50243k · Cited by 309
Self-citationThe relevance and potential roles of microphysiological systems in biology and medicine
Wikswo, J. P. (2014) · Experimental Biology and Medicine · doi:10.1177/1535370214542068 · Cited by 248
Self-citation
Metadata
- Authors
- Wikswo, J. P., Prokop, A., Baudenbacher, F., Cliffel, D., Csukas, B., & Velkovsky, M.
- Venue
- IEE Proceedings - Nanobiotechnology
- Published
- 2006
- Volume
- 153
- Issue
- 4
- Pages
- 81
- ISSN
- 1478-1581 (ISSN-L)
- OpenAlex
- W2094441177
- Cited by
- 51
- References
- 8
- FWCI
- 3.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Engineering challenges of BioNEMS: the integration of microfluidics, micro- and nanodevices, models and external control for systems biology. https://app.cochat.ai/papers/10.1049/ip-nbt:20050045
- The paper
- Wikswo, J. P., Prokop, A., Baudenbacher, F., Cliffel, D., Csukas, B., & Velkovsky, M. (2006). Engineering challenges of BioNEMS: the integration of microfluidics, micro- and nanodevices, models and external control for systems biology. IEE Proceedings - Nanobiotechnology. https://doi.org/10.1049/ip-nbt%3A20050045
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.