CoChat

The relevance and potential roles of microphysiological systems in biology and medicine

Open access
Wikswo, John P · 2014 · Experimental Biology and Medicine

The DOI matches its Crossref record; 78 of the 78 references it cites were found in a registry or an index.

Abstract

Microphysiological systems (MPS), consisting of interacting organs-on-chips or tissue-engineered, 3D organ constructs that use human cells, present an opportunity to bring new tools to biology, medicine, pharmacology, physiology, and toxicology. This issue of Experimental Biology and Medicine describes the ongoing development of MPS that can serve as in-vitro models for bone and cartilage, brain, gastrointestinal tract, lung, liver, microvasculature, reproductive tract, skeletal muscle, and skin. Related topics addressed here are the interconnection of organs-on-chips to support physiologically based pharmacokinetics and drug discovery and screening, and the microscale technologies that regulate stem cell differentiation. The initial motivation for creating MPS was to increase the speed, efficiency, and safety of pharmaceutical development and testing, paying particular regard to the fact that neither monolayer monocultures of immortal or primary cell lines nor animal studies can adequately recapitulate the dynamics of drug-organ, drug-drug, and drug-organ-organ interactions in humans. Other applications include studies of the effect of environmental toxins on humans, identification, characterization, and neutralization of chemical and biological weapons, controlled studies of the microbiome and infectious disease that cannot be conducted in humans, controlled differentiation of induced pluripotent stem cells into specific adult cellular phenotypes, and studies of the dynamics of metabolism and signaling within and between human organs. The technical challenges are being addressed by many investigators, and in the process, it seems highly likely that significant progress will be made toward providing more physiologically realistic alternatives to monolayer monocultures or whole animal studies. The effectiveness of this effort will be determined in part by how easy the constructs are to use, how well they function, how accurately they recapitulate and report human pharmacology and toxicology, whether they can be generated in large numbers to enable parallel studies, and if their use can be standardized consistent with the practices of regulatory science.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1177/1535370214542068

Cites

78 of 78 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 78 references

Research works printed but not linked: 5

  1. Avis FR, 1961, Sci Teacher, 28, 14
  2. Zimmer HG, 1998, News Physiol Sci, 13, 203
  3. Exton JH, 2013, Crucible of science: the story of the Cori laboratory
  4. Fisher RA, 1926, J Min Agric G Br, 33, 503
  5. 10.1001/jama.2009.1212 · DOI

Cited by

See all 248

Metadata

Authors
Wikswo, J. P.
Affiliations
Vanderbilt University (US)
Corresponding author
Wikswo, John P
Venue
Experimental Biology and Medicine
Published
2014-09
Volume
239
Issue
9
Pages
1061-1072
ISSN
  • 0071-3384 (ISSN-L)
  • 1535-3702
  • 1535-3699
OpenAlex
W2134377528
Cited by
248
References
78
Citations by year
2026: 14 · 2025: 20 · 2024: 23 · 2023: 21 · 2022: 15 · 2021: 21 · 2020: 22 · 2019: 21 · 2018: 20 · 2017: 27 · 2016: 28 · 2015: 15 · 2014: 1
FWCI
12.28
Type
journal article
Language
en
Open access
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Experimental Biology and Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • National Institutes of Health (UH3TR000491, UH2TR000491)
  • National Center for Advancing Translational Sciences
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
  • Health Sciences › Medicine › Surgery › Tissue Engineering and Regenerative Medicine
  • Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
Keywords
microphysiological systems, organ-on-a-chip, in vitro model, physiologically based pharmacokinetic modeling, toxicology, stem cell differentiation, induced pluripotent stem cells, alternatives to animal testing, microbiome, chemical and biological weapons, regulatory science
MeSH terms
Adult, Bioprosthesis, Female, Humans, Male, Tissue Engineering

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The relevance and potential roles of microphysiological systems in biology and medicine. https://app.cochat.ai/papers/10.1177/1535370214542068
The paper
Wikswo, J. P. (2014). The relevance and potential roles of microphysiological systems in biology and medicine. Experimental Biology and Medicine. https://doi.org/10.1177/1535370214542068

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.