The diameters of α Centauri A and B: A comparison of the asteroseismic and VINCI/VLTI views
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
We compare the first direct angular diameter measurements obtained on our closest stellar neighbour, α Centauri, to recent model diameters constrained by asteroseismic observations. Using the VINCI instrument installed at ESO's VLT Interferometer (VLTI), the angular diameters of the two main components of the system, α Cen A and B, were measured with a relative precision of 0.2% and 0.6% respectively. Particular care has been taken in the calibration of these measurements, considering that VINCI is estimating the fringe visibility using a broadband K filter. We obtain uniform disk angular diameters for α Cen A and B of mas and mas, and limb darkened angular diameters of mas and mas. Combining these values with the parallax from Söderhjelm (1999), we derive linear diameters of and . These values are compatible with the masses published by Thévenin et al. (2002) for both stars.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
WAVELET TRANSFORMS AND THEIR APPLICATIONS TO TURBULENCE
Farge, M. (1992) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.24.010192.002143 · Cited by 3,062 · cited 1×
“We implemented in this code a timefrequency analysis (Ségransan et al. 1999) based on the continuous wavelet transform (Farge 1992).”
MethodCohen, M., Walker, R. G., Carter, B., Hammersley, P., Kidger, M., & Noguchi, K. (1999) · The Astronomical Journal · doi:10.1086/300813 · Cited by 525 · cited 4×
“This calibrator was chosen for its stability and brightness in the list of standard stars compiled by Cohen et al. (1999) and verified by Bordé et al. (2002).”
BackgroundMethodInfluentialCESAM: A code for stellar evolution calculations
Morel, P. (1997) · Astronomy & Astrophysics Supplement Series · doi:10.1051/aas:1997209 · Cited by 462 · cited 1×
“This calibration was based on stellar evolution models computed using the CESAM code (Morel 1997).”
MethodSelf-citationA catalogue of [Fe/H] determinations: 1996 edition
de Strobel, G. C., Soubiran, C., Friel, E. D., Ralite, N., & François, P. (1997) · Astronomy and Astrophysics Supplement Series · doi:10.1051/aas:1997194 · Cited by 212
First radius measurements of very low mass stars with the VLTI
Ségransan, D., Kervella, P., Forveille, T., & Queloz, D. (2003) · Astronomy & Astrophysics · doi:10.1051/0004-6361:20021714 · Cited by 195 · cited 1×
“As a remark, the angular diameter of Proxima has also been measured recently for the first time (θLD = 1.02 ± 0.08 mas) using two 8-meters Unit Telescopes and the VINCI instrument (Ségransan et al. 2003).”
MethodInfluentialSelf-citationPourbaix, D., Nidever, D. L., McCarthy, C., Butler, R. P., Tinney, C. G., Marcy, G. W., Jones, H. R. A., Penny, A. J., Carter, B., Bouchy, F., et al. (2002) · Astronomy and Astrophysics · doi:10.1051/0004-6361:20020287 · Cited by 159 · cited 4×
“The mass of the B component departs significantly by 3% from the value published by Pourbaix et al. (2002).”
BackgroundMethodInfluentialAsteroseismology and calibration ofα Cen binary system
Thévenin, F., Provost, J., Morel, P., Berthomieu, G., Bouchy, F., & Carrier, F. (2002) · Astronomy and Astrophysics · doi:10.1051/0004-6361:20021074 · Cited by 145
Self-citationGuenther, D. B., & Demarque, P. (2000) · The Astrophysical Journal · doi:10.1086/308446 · Cited by 98 · cited 1×
“…for the star A have largely forced the spectro-photometric calibration to decrease the masses of the stellar system αCen, leading to the following values: MA = 1.100 ± 0.006M⊙ and MB = 0.907 ± 0.006M⊙ (Thévenin et al. 2002) close to those adopted by Guenther & Demarque (2000) and Kim (2000).”
MethodInfluentialA new seismic analysis of Alpha Centauri
Thoul, A., Scuflaire, R., Noels-Grötsch, A., Vatovez, B., Briquet, M., Dupret, M. ‐., & Montalbán, J. (2003) · Astronomy and Astrophysics · doi:10.1051/0004-6361:20030244 · Cited by 56 · cited 1×
“We note that Thoul et al. (2003) have recently proposed a model of the binary system using these masses and spectro-photometric constraints different from that of Thévenin et al. (2002).”
MethodA new seismic analysis of Alpha Centauri
Thoul, A. A., Scuflaire, R., Noels-Grötsch, A., Vatovez, B., Briquet, M., Dupret, M. ‐., & Montalbán, J. (2003) · Springer Link (Chiba Institute of Technology) · doi:10.1051/0004-6361:20030244/pdf · Cited by 42
TheζHerculis binary system revisited: Calibration and seismology
Morel, P., Berthomieu, G., Provost, J., & Thévenin, F. (2001) · Astronomy and Astrophysics · doi:10.1051/0004-6361:20011336 · Cited by 14 · cited 1×
“Several binary systems like αCen (see Morel et al. 2001 for references) have been calibrated using spectro-photometry constraints.”
MethodSelf-citation
Cited by
Valenti, J. A., & Fischer, D. A. (2005) · The Astrophysical Journal Supplement Series · doi:10.1086/430500 · Cited by 1,460
Accurate masses and radii of normal stars: modern results and applications
Torres, G., Andersen, J., & Giménez, A. (2010) · The Astronomy and Astrophysics Review · doi:10.1007/s00159-009-0025-1 · Cited by 1,418
An Earth-mass planet orbiting α Centauri B
Dumusque, X., Pepe, F., Lovis, C., Ségransan, D., Sahlmann, J., Benz, W., Bouchy, F., Mayor, M., Queloz, D., Santos, N., et al. (2012) · Nature · doi:10.1038/nature11572 · Cited by 404
Self-citationProxima’s orbit around α Centauri
Kervella, P., Thévenin, F., & Lovis, C. (2017) · Astronomy & Astrophysics · doi:10.1051/0004-6361/201629930 · Cited by 298
Self-citationGaia FGK benchmark stars: Effective temperatures and surface gravities
Heiter, U., Jofré, P., Gustafsson, B., Korn, A. J., Soubiran, C., & Thévenin, F. (2015) · Astronomy & Astrophysics · doi:10.1051/0004-6361/201526319 · Cited by 297
Self-citation
Metadata
- Authors
- Kervella, P., Thévenin, F., Ségransan, D., Berthomieu, G., Lopez, B., Morel, P., & Provost, J.
- Venue
- Astronomy & Astrophysics
- Publisher
- EDP Sciences
- Published
- 2003-06
- Volume
- 404
- Issue
- 3
- Pages
- 1087-1097
- ISSN
- 0004-6361 (ISSN-L)
- 1432-0746
- OpenAlex
- W4289788995
- Cited by
- 159
- References
- 11
- FWCI
- 7.15
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.