The DOI matches its Crossref record.
Comparison of harmonic limits and evaluation of the international standards
Open accessAbstract
The paper takes the Chinese standard GB/T 14549-1993, the British Engineering Recommendation G5/4-1, the Institute of Electrical and Electronics Engineers IEEE Std 519-2014 and the part of IEC 61000-3 series standard as an example. Then summarize the difference of harmonic limits, the different processing methods of harmonic impedance, and the different summation law of each standard. Compare the harmonic limit calculation and evaluation methods of Chinese GB/T 14549-1993, British G5/4-1 and IEEE Std 519-2014 standard in detail, summarize the characteristics of the three standards in disturbance emission evaluation and introduce examples to verify the conclusion. Finally, summarize the characteristics and differences of mentioned harmonic standards.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Greater harmonics produced by semiconductor current converters affect the sinusoidal voltage and increase the reactive component of current.
“Greater harmonics produced by semiconductor current converters affects the sinusoidal voltage and increase reactive component of current by voltage.”
From Enriched I-Q Active Filter Based Harmonics Mitigation in Rectifier-Inverter Fed Induction Motor Drive (2025) · cites this paper as [26]
Section 4, “The comparison of summation laws” (page unavailable), discusses harmonics generated by grid sources and the resulting harmonic voltage. Section 5.1 also addresses harmonic voltage distortion. Neither passage identifies semiconductor current converters as the source or says that harmonics increase the reactive component of current. (LLM, conf=0.82)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 5
- LIN Haixue Introduction to the Foreign Standards of Harmonic Current Limits Distribution & Utilization 2008(05):1-8
- MO Qing, SUN Haoliang Basis and Derivation of Harmonic Current Limits in IEC Standards for Power Equipments Power System Technology 2000(04):67-70
- LIN, 2012, 519 Distribution & Utilization, 29, 11
- IEEE Recommended Practice and Requirements for Harmonic Control in Electric Power Systems (IEEE Std 519-2014)
- LIN Haixue On Difference Between National Standard and IEC 61000 Standards of EMC in Harmonic Power System Technology 1999(05):64-67
Cited by
Sorted by citations
Kadir Sheikh, S., Jain, M., & Chandrakant Tapre, P. (2025) · Tehnički glasnik · doi:10.31803/tg-20230822132129 · Cited by 2
“These kinds of converters frequently consume harmonic current as well as reactive power through the AC distribution, which negatively affects power quality [25, 26].”
Metadata
- Authors
- WANG, Z., LI, Q., TANG, Y., LIU, S., & DAI, S.
- Affiliations
- Zhengzhou University (CN)
- State Grid Henan Electric Power Company (China) (CN)
- Venue
- MATEC Web of Conferences
- Publisher
- EDP Sciences
- Published
- 2019
- Volume
- 277
- Pages
- 03009
- ISSN
- 2261-236X (ISSN-L)
- OpenAlex
- W2933034179
- Cited by
- 8
- References
- 0
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 2 · 2022: 2 · 2021: 2
- FWCI
- 1.59
- Type
- conference paper
- Language
- en
- Open access
- diamond
- doi.org
- Licence
- Locations
- MATEC Web of Conferences (publishedVersion, cc-by)
- Springer Link (Chiba Institute of Technology) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Noise Suppression
- Keywords
- harmonic limits, power quality standards, harmonic impedance, harmonic distortion measurement, standard comparison
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review