Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 32 of the 33 references it cites were found in a registry or an index; 4 of the 10 sources its claims cite were checked for support.

Enriched I-Q Active Filter Based Harmonics Mitigation in Rectifier-Inverter Fed Induction Motor Drive

Open access
Kadir Sheikh, Samsher, Jain, Manish, Chandrakant Tapre, Pawan · 2025 · Tehnički glasnik

Abstract

The paper examines power-quality issues in an induction motor drive system attached to a utility grid. An instantaneous imaginary controller-based shunt active power filter (I-Q active filter) is employed to lessen the harmonic content in the current at the point of source. Outcomes are analysed in MATLAB/Simulink.

Overview

CoChat Summary

TL;DR

This paper proposes an enriched instantaneous imaginary controller-based shunt active power filter (I-Q active filter) to mitigate current harmonics in a rectifier-inverter-fed induction motor drive, modeled in MATLAB/Simulink. It reports reducing THD from 25.68% without filtering to 1.75% with the proposed filter for a single-drive system.

Key findings

  • For the single-drive induction motor system, the proposed filter reduced THD from 25.68% without filter to 1.75% with filter.
  • Comparative THD with filter: conventional SAF 5.45%, PI-SAF 13.60%, PID-SAF 3.86%, FLC-SAF 2.66%, and proposed enriched SAF 1.75%; corresponding without-filter values were 46.47%, 20.29%, 16.51%, 7.52%, and 25.68%.
  • Under varying load torque (Tfl = 49.7 Nm, Tfl/2 = 24.86 Nm, Tfl/4 = 12.43 Nm, T0 = 0 Nm at t = 0.2 s, 0.5 s, and 0.7 s), the proposed model maintained a consistent rotor speed of 150 rad/s; rotor current oscillated up to 0.35 s and then stabilized.
  • The paper concludes that the proposed filter provides excellent harmonic reduction and adheres to IEEE-519 harmonic control norms.

Methods

  • Design: a shunt active power filter using an instantaneous imaginary power (I-Q) controller and hysteresis current control; it transforms three-phase voltages and currents into αβ0 coordinates, computes instantaneous real and reactive power, generates reference compensation currents, and uses hysteresis control to produce VSI switching signals.
  • Data/sample: MATLAB/Simulink model of a three-phase nonlinear induction motor drive system; simulation runs for 1 second pre-compensation, then the enriched I-Q active filter provides compensation current. Parameters include source 415 V, 50 Hz; induction motor 10 HP, 400 V, 50 Hz, 1440 rpm; VSI 4700 µF, Vdbus = 560 V; DC-link capacitor 1000 µF; PI gains Kp = 7.5, Ki = 9.
  • Main analysis: THD analysis of load/source current with and without the filter, plus comparison against existing shunt active filters.

Limitations

  • The paper does not include an explicit limitations section. Evident from the text: results are simulation-only in MATLAB/Simulink, with no experimental or hardware validation reported.
  • The study evaluates only a single-drive induction motor system; no multi-drive or broader grid-scale validation is presented.
  • The provided text is fragmented and repetitive, with some equations and figures incomplete, making full methodological replication difficult.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.31803/tg-20230822132129

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Figures

Image 1
CC-BY · From the PDF
Figure 2 Electrical Waveforms Harmonic
Figure 2 Electrical Waveforms HarmonicCC-BY · From the PDF
Image 3
CC-BY · From the PDF
Image 4
CC-BY · From the PDF
Figure 5 Active power filter equivalent circuit
Figure 5 Active power filter equivalent circuitCC-BY · From the PDF
Figure 6 Power component current compensation-based coordinates
Figure 6 Power component current compensation-based coordinatesCC-BY · From the PDF
Figure 7 Block diagram of proposed system
Figure 7 Block diagram of proposed systemCC-BY · From the PDF
Figure 8 Proposed work MATLAB/Simulink model
Figure 8 Proposed work MATLAB/Simulink modelCC-BY · From the PDF
Image 9
CC-BY · From the PDF
Image 10
CC-BY · From the PDF
Image 11
CC-BY · From the PDF
Image 12
CC-BY · From the PDF
Figure 14 Induction motor stator current waveform
Figure 14 Induction motor stator current waveformCC-BY · From the PDF
Image 14
CC-BY · From the PDF
Image 15
CC-BY · From the PDF
Image 16
CC-BY · From the PDF
Figure 19 Percentage of THD without considering filter
Figure 19 Percentage of THD without considering filterCC-BY · From the PDF
Figure 20 Percentage of THD with filter
Figure 20 Percentage of THD with filterCC-BY · From the PDF
Percentage THD
Percentage THDCC-BY · From the PDF

Verification

Claims the paper makes

3 Valid · 0 Not valid · 5 Not checked · 21 Own results and interpretations

5 more claims

Create a free account to see all 29 claims and to verify the 1 reference still open.

See all claims — free account
  • Probably not a substantial claim. 6
  • It may state two separate claims as one. 14
  • The quote only partly states this claim. 1

Create a free account to see these claims.

Citations

Cites

Show all 33 references

Research works printed but not linked: 1

  1. [24]24. Scheuer, G., Schmage, T. & Krishnan, L. C. (2007). Medium voltage drives in the sugar industry. International sugar journal, 1301, 303.

Cited by

See all 2

Metadata

Authors
Kadir Sheikh, S., Jain, M., & Chandrakant Tapre, P.
Affiliations
  • Department of Electrical and Electronics Engineering, Mandsaur University
  • Mandsaur University (IN)
Venue
Tehnički glasnik
Published
2025-04-07
Volume
19
Issue
2
Pages
181-191
ISSN
  • 1846-6168 (ISSN-L)
  • 1848-5588
OpenAlex
W4409269113
Cited by
2
References
33
Citations by year
2025: 2
FWCI
0.45
Type
journal article
Language
en
Open access
Licence
cc-by
Locations
  • Tehnički glasnik (publishedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • University of Zagreb University Computing Centre (SRCE) (submittedVersion, other-oa)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Noise Suppression
Keywords
harmonic compensation, shunt active power filter, induction motor drive, rectifier-inverter, total harmonic distortion, power quality, sugar industry, point of common coupling, reactive power compensation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

The claim verdicts this report counts are experimental: their accuracy is not yet measured.

A language model drew the claims from the paper on 2026-10-10, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-10-10 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Enriched I-Q Active Filter Based Harmonics Mitigation in Rectifier-Inverter Fed Induction Motor Drive. https://app.cochat.ai/papers/10.31803/tg-20230822132129
The paper
Kadir Sheikh, S., Jain, M., & Chandrakant Tapre, P. (2025). Enriched I-Q Active Filter Based Harmonics Mitigation in Rectifier-Inverter Fed Induction Motor Drive. Tehnički glasnik. https://doi.org/10.31803/tg-20230822132129

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.