Microscope imaging by time-of-flight secondary ion mass spectrometry
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The concept of Secondary Ion Microscopy, introduced by Castaing et al. [1], is applied to a direct imaging time-of-flight (TOF) mass spectrometer.The ion optical configuration for a par- ticular [2] stigmatic imaging TOF mass spectrometer is reviewed.A number of fundamental factors influencing the mass resolution in any TOF spectrometer are discussed.The question of where micro- scope imaging offers advantages over microprobe imaging in TOF Secondary Ion Mass Spectrometry is addressed.Microsc.MicroanaL Microstruct.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Matrix-assisted ultraviolet laser desorption of non-volatile compounds
Karas, M., Bachmann, D., Bahr, U., & Hillenkamp, F. (1987) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(87)87041-6 · Cited by 1,953
Multiple-focusing time-of-flight mass spectrometers Part II. TOFMS with equal energy acceleration
Poschenrieder, W. P. (1972) · International Journal of Mass Spectrometry and Ion Physics · doi:10.1016/0020-7381(72)80020-2 · Cited by 249
A time-of-flight secondary ion microscope
Schueler, B. W., Sander, P., & Reed, D. A. (1990) · Vacuum · doi:10.1016/0042-207x(90)94047-t · Cited by 99
Self-citationIon optics for time-of-flight mass spectrometers with multiple symmetry
Sakurai, T., Matsuo, T., & Matsuda, H. (1985) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(85)80030-6 · Cited by 55
Cited by
McDonnell, L. A., & Heeren, R. M. A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20124 · Cited by 1,082
Imaging with Mass Spectrometry
Pacholski, M. L., & Winograd, N. (1999) · Chemical Reviews · doi:10.1021/cr980137w · Cited by 302
Gold-Enhanced Biomolecular Surface Imaging of Cells and Tissue by SIMS and MALDI Mass Spectrometry
Altelaar, A. F. M., Klinkert, I., Jalink, K., de Lange, R. P. J., Adan, R. A. H., Heeren, R. M. A., & Piersma, S. R. (2006) · Analytical Chemistry · doi:10.1021/ac0513111 · Cited by 278
High-Spatial Resolution Mass Spectrometric Imaging of Peptide and Protein Distributions on a Surface
Luxembourg, S. L., Mize, T. H., McDonnell, L. A., & Heeren, R. M. A. (2004) · Analytical Chemistry · doi:10.1021/ac049692q · Cited by 267
Autoradiography, MALDI-MS, and SIMS-MS Imaging in Pharmaceutical Discovery and Development
Solon, E. G., Schweitzer, A., Stoeckli, M., & Prideaux, B. (2010) · The AAPS Journal · doi:10.1208/s12248-009-9158-4 · Cited by 250
“described, whereby the spatial resolution is independent of the spot size of the primary ion beam (96).”
Metadata
- Authors
- Schueler, B. W.
- Venue
- Microscopy Microanalysis Microstructures
- Publisher
- EDP Sciences
- Published
- 1992
- Volume
- 3
- Issue
- 2-3
- Pages
- 119-139
- ISSN
- 1154-2799 (ISSN-L)
- OpenAlex
- W2066920231
- Cited by
- 217
- References
- 4
- FWCI
- 7.47
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.