The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Bioabsorbable Interference Screws for Graft Fixation in Anterior Cruciate Ligament Reconstruction
Abstract
The central one third of the patellar tendon autograft is popular because the bone-tendon-bone (BTB) construct provides several graft fixation options, robust graft incorporation, and a mechanically sufficient substitute. Interference screw fixation is one method used to secure the graft. Bioabsorbable interference screws may offer advantages over metal interference screws. Bioabsorbable screws are made from poly L-lactic acid (PLLA) and are absorbed by the body. This prospective, randomized study compared the safety and efficacy of the PLLA screw with that of the metal cannulated interference screw for anterior cruciate ligament reconstruction. There were 204 patients randomly assigned to the Bioscrew (Linvatec, Largo, FL) (n = 103) or the metal interference screw (n = 101) groups at four sites. The mean age was 30 years. There were 66 women and 138 men. Mean follow-up was 30 months for Bioscrews and 28 months for metal screws; the average follow-up interval was 2.4 years. The Lysholm mean scores at 4 years for the 32 patients seen at this interval were 95.0 and 97.2 for the Bioscrew and metal screw group, respectively. Ligament laxity comparisons made with an instrumented arthrometer at manual maximum force resulted in side-to-side mean score differences of B = 1.8mm and M = 1.6mm. The Tegner activity level score means were B = 6.1 and M = 5.8. Other variables examined included pain, thigh size, meniscal tests, Lachman's test, range of motion, anterior drawer, pivot shift, patellofemoral crepitus and tenderness, and joint effusion. None of these variables showed a statistically significant difference between groups. No radiographic evidence of osteolytic change or bone resorption around the Bioscrews was observed. There were no complications related to loss of fixation, toxicity, allergenicity, or other evidence of osteolytic or inflammatory reaction. In every assessment between groups there was no difference found. There were 12 PLLA screws that broke during insertion without any adverse effects. The PLLA headless cannulated interference fit screws produce equal results to similarly designed metal screws.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rating systems in the evaluation of knee ligament injuries
TEGNER, Y., & LYSHOLM, J. (1985) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198509000-00007 · Cited by 4,613
Preliminary results of an absorbable interference screw
Barber, F. A., Elrod, B. F., McGuire, D. A., & Paulos, L. E. (1995) · Arthroscopy · doi:10.1016/0749-8063(95)90129-9 · Cited by 178
Self-citation
Cited by
Bone repair in the twenty–first century: biology, chemistry or engineering?
Hing, K. A. (2004) · Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2004.1466 · Cited by 400
Weiler, A., Peters, G., Mäurer, J., Unterhauser, F. N., & Südkamp, N. P. (2001) · The American Journal of Sports Medicine · doi:10.1177/03635465010290061401 · Cited by 287
Åkerlund, E., Diez-Escudero, A., Grzeszczak, A., & Persson, C. (2022) · Polymers · doi:10.3390/polym14163305 · Cited by 80
Metadata
- Authors
- McGuire, D. A., Barber, F. A., Elrod, B. F., & Paulos, L. E.
- Venue
- Arthroscopy: The Journal of Arthroscopic & Related Surgery
- Publisher
- Elsevier BV
- Published
- 1999-07
- Volume
- 15
- Issue
- 5
- Pages
- 463-473
- ISSN
- 0749-8063 (ISSN-L)
- OpenAlex
- W2006653667
- Cited by
- 165
- References
- 2
- FWCI
- 6.16
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Bioabsorbable Interference Screws for Graft Fixation in Anterior Cruciate Ligament Reconstruction. https://app.cochat.ai/papers/10.1053/ar.1999.v15.015046001
- The paper
- McGuire, D. A., Barber, F. A., Elrod, B. F., & Paulos, L. E. (1999). Bioabsorbable Interference Screws for Graft Fixation in Anterior Cruciate Ligament Reconstruction. Arthroscopy: The Journal of Arthroscopic & Related Surgery. https://doi.org/10.1053/ar.1999.v15.015046001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.