The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Six-minute walking performance in patients with moderate-to-severe heart failure; is it a useful indicator in clinical practice?
Abstract
AIMS: The 6-min walk test has been incorporated into studies on the efficacy of new therapies and into prognostic stratification for chronic heart failure patients. Firm conclusions on the usefulness of the test in clinical practice are still lacking. The aim of this study was to investigate (1) the correlation between walk test performance and standard indices of cardiac function and exercise capacity, and (2) the prognostic value of the walk test with respect to peak VO2 and NYHA class. METHODS AND RESULTS: Three hundred and fifteen chronic heart failure patients (age: 53+/-9 years, NYHA class: II (182), III (133)) underwent a functional evaluation and a 6-min walk test. Of these, 270 were followed-up for a minimum of 6 months (mean 387+/-177 days). Walked distance was 396+/-92 m. There was no significant correlation between distance walked and central haemodynamic data. Functional capacity, as measured by ergometry, correlated moderately with distance walked (duration: r=0.48, peak VO2: r=0.59, anaerobic threshold: r=0.54; all P<0.001). During follow-up, 46 patients died from cardiovascular causes and 12 were urgently transplanted. Either of these events were considered end points of the study. Survival analysis was performed from a continuous walk test and peak VO2 measurements or after categorization of (a) quartile segmentation, (b) cut-off points from the literature and (c) thresholds from receiver operating characteristic curves. At univariate survival analysis (Cox regression), the association of the walk test with survival was of significance (P=0.03, continuous variable), or borderline significance (0.05< or =P< or =0.1, after categorization). Peak VO2 was always significant, independent of the scale used (0.005< or =P< or =0.03). The strongest association was found for NYHA class (P<0.001), which showed the highest sensitivity and specificity for the prediction of the event (0.64 and 0.65, respectively). When walk test performance, continuous or categorized, was entered into a multivariate model with NYHA class or peak VO2, it lost any significant association with survival (P>0.76 in all models with NYHA class and P>0.27 in all models with peak VO2). CONCLUSION: In moderate-to-severe chronic heart failure patients, the 6-min walk test is not related to cardiac function and only moderately related to exercise capacity. Walking performance does not provide prognostic information which can complement or substitute for that provided by peak VO2 or NYHA class. Hence the test is of limited usefulness as a decisional indicator in clinical practice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
Cited by
6-minute walking test: a useful tool in the management of heart failure patients
Giannitsi, S., Bougiakli, M., Bechlioulis, A., Kotsia, A., Michalis, L. K., & Naka, K. K. (2019) · Therapeutic Advances in Cardiovascular Disease · doi:10.1177/1753944719870084 · Cited by 375
The six minute walk test accurately estimates mean peak oxygen uptake
Ross, R. M., Murthy, J. N., Wollak, I. D., & Jackson, A. S. (2010) · BMC Pulmonary Medicine · doi:10.1186/1471-2466-10-31 · Cited by 338
McKelvie, R. S., Teo, K. K., Roberts, R., McCartney, N., Humen, D., Montague, T., Hendrican, K., & Yusuf, S. (2002) · American Heart Journal · doi:10.1067/mhj.2002.123310 · Cited by 322
Exercise based rehabilitation for heart failure
Rees, K., Taylor, R. R., Singh, S., Coats, A. J., & Ebrahim, S. (2004) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd003331.pub2 · Cited by 253
Lissin, L. W., Gauri, A. J., Froelicher, V. F., Ghayoumi, A., Myers, J., & Giacommini, J. (2002) · Journal of Cardiac Failure · doi:10.1054/jcaf.2002.126812 · Cited by 94
Metadata
- Authors
- Opasich, C.
- Venue
- European Heart Journal
- Publisher
- Oxford University Press (OUP)
- Published
- 2001-03-15
- Volume
- 22
- Issue
- 6
- Pages
- 488-496
- ISSN
- 0195-668X (ISSN-L)
- OpenAlex
- W2040801489
- Cited by
- 196
- References
- 1
- FWCI
- 21.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Six-minute walking performance in patients with moderate-to-severe heart failure; is it a useful indicator in clinical practice? https://app.cochat.ai/papers/10.1053/euhj.2000.2310
- The paper
- Opasich, C. (2001). Six-minute walking performance in patients with moderate-to-severe heart failure; is it a useful indicator in clinical practice? European Heart Journal. https://doi.org/10.1053/euhj.2000.2310
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.