Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

A method of comparing the areas under receiver operating characteristic curves derived from the same cases

Hanley, J A, McNeil, B J · 1983 · Radiology

Abstract

Receiver operating characteristic (ROC) curves are used to describe and compare the performance of diagnostic technology and diagnostic algorithms. This paper refines the statistical comparison of the areas under two ROC curves derived from the same set of patients by taking into account the correlation between the areas that is induced by the paired nature of the data. The correspondence between the area under an ROC curve and the Wilcoxon statistic is used and underlying Gaussian distributions (binormal) are assumed to provide a table that converts the observed correlations in paired ratings of images into a correlation between the two ROC areas. This between-area correlation can be used to reduce the standard error (uncertainty) about the observed difference in areas. This correction for pairing, analogous to that used in the paired t-test, can produce a considerable increase in the statistical sensitivity (power) of the comparison. For studies involving multiple readers, this method provides a measure of a component of the sampling variation that is otherwise difficult to obtain.

Overview

Integrity signals

Registry

Crossref · 10.1148/radiology.148.3.6878708

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 6 references

Cited by

See all 7,016

Metadata

Authors
Hanley, J. A., & McNeil, B. J.
Venue
Radiology
Published
1983-09
Volume
148
Issue
3
Pages
839-843
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2102150307
Cited by
7,016
References
6
Citations by year
2026: 93 · 2025: 143 · 2024: 153 · 2023: 187 · 2022: 238 · 2021: 243 · 2020: 229 · 2019: 261 · 2018: 249 · 2017: 220 · 2016: 273 · 2015: 282 · 2014: 290 · 2013: 287 · 2012: 306
FWCI
8.95
Type
journal article
Language
en
Open access
closed
Locations
  • Radiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
  • Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
  • Physical Sciences › Computer Science › Artificial Intelligence › Imbalanced Data Classification Techniques
Keywords
receiver operating characteristic, area under the ROC curve, Wilcoxon statistic, diagnostic accuracy comparison, multiple readers, statistical power, standard error correction
MeSH terms
Models, Theoretical, Probability, Statistics as Topic, Technology, Radiologic

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A method of comparing the areas under receiver operating characteristic curves derived from the same cases. https://app.cochat.ai/papers/10.1148/radiology.148.3.6878708
The paper
Hanley, J. A., & McNeil, B. J. (1983). A method of comparing the areas under receiver operating characteristic curves derived from the same cases. Radiology. https://doi.org/10.1148/radiology.148.3.6878708

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.