Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,126

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials

Connolly, S·2000·European Heart Journal

Abstract

AIMS: Three randomized trials of implantable cardioverter defibrillator (ICD) therapy vs medical treatment for the prevention of death in survivors of ventricular fibrillation or sustained ventricular tachycardia have been reported with what might appear to be different results. The present analysis was performed to obtain the most precise estimate of the efficacy of the ICD, compared to amiodarone, for prolonging survival in patients with malignant ventricular arrhythmia. METHODS AND RESULTS: Individual patient data from the Antiarrhythmics vs Implantable Defibrillator (AVID) study, the Cardiac Arrest Study Hamburg (CASH) and the Canadian Implantable Defibrillator Study (CIDS) were merged into a master database according to a pre-specified protocol. Proportional hazard modelling of individual patient data was used to estimate hazard ratios and to investigate subgroup interactions. Fixed effect meta-analysis techniques were also used to evaluate treatment effects and to assess heterogeneity across studies. The classic fixed effects meta-analysis showed that the estimates of ICD benefit from the three studies were consistent with each other (P heterogeneity=0.306). It also showed a significant reduction in death from any cause with the ICD; with a summary hazard ratio (ICD:amiodarone) of 0.72 (95% confidence interval 0.60, 0.87;P=0.0006). For the outcome of arrhythmic death, the hazard ratio was 0.50 (95% confidence interval 0.37, 0.67;P<0.0001). Survival was extended by a mean of 4.4 months by the ICD over a follow-up period of 6 years. Patients with left ventricular ejection fraction < or = 35% derived significantly more benefit from ICD therapy than those with better preserved left ventricular function. Patients treated before the availability of non-thoracotomy ICD implants derived significantly less benefit from ICD therapy than those treated in the non-thoracotomy era. CONCLUSION: Results from the three trials of the ICD vs amiodarone are consistent with each other. There is a 28% reduction in the relative risk of death with the ICD that is due almost entirely to a 50% reduction in arrhythmic death.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1053/euhj.2000.2476

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 1,126

Metadata

Authors
Connolly, S.
Venue
European Heart Journal
Published
2000-12-15
Volume
21
Issue
24
Pages
2071-2078
ISSN
0195-668X (ISSN-L)
OpenAlex
W2148566864
Cited by
1,126
References
1
FWCI
3.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.