Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 196

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Left and Right Atrial Volume by Freehand Three-dimensional Echocardiography: In Vivo Validation Using Magnetic Resonance Imaging

KELLER, A, GOPAL, A, KING, D·2000·European Journal of Echocardiography

Abstract

INTRODUCTION: Measurement of left and right atrial size is important for the management of arrhythmias, valvular and congenital heart disease. We have demonstrated that freehand three-dimensional (3D) echocardiography is more accurate and reproducible than two-dimensional (2D) echocardiography for measurement of left ventricular mass and volume. However, no prior study has validated the accuracy of freehand 3D for the determination of left or right atrial volume. METHODS: End-systolic (maximum) left and right atrial volumes were determined in 21 volunteer patients and normal subjects by one, two, and freehand 3D transthoracic echocardiography and compared to volumes obtained by gradient recalled magnetic resonance imaging. Three-dimensional echocardiographic determination of atrial volume was obtained using an acoustic spatial locator, a line-of-intersection display, and a surface reconstruction algorithm. Two-dimensional echocardiographic atrial volumes were obtained from apical biplane images of the left atrium and an apical single plane image of the right atrium using a summation of disks method. One-dimensional (ID) estimates of left atrial volume were determined by cubing the M-mode ID antero-posterior dimension obtained on the parasternal long axis view. RESULTS: An excellent correlation was Obtained between freedhand 3D echocardiography and magnetic resonce imaging (MRI) for the left atrium (r = 0.90, SEE=9.6 ml) and for the right atrium (r = 0.91, SEE = 8.8 ml) with a small bias (left atrium 5.25 ml, right atrium 12.06 ml) and narrow limits of agreement (left atrium 22.14 ml, right atrium 25.54 ml). Two-dimensional echocardiography correlated less well (left atrium r = 0.87, SEE = 10.23 ml, right atrium r = 0.79, SEE = 19.74 ml), and had a higher bias (left atrium 14.46 ml, right atrium 8.99 ml) and larger limits of agreement (left atrium 24.37 ml, right atrium 41.16 ml). One-dimensional estimates of left atrial volume correlated poorly with magnetic resonance determined left atrial volume (r = 0.80, SEE = 6.61 ml) and had unacceptably high bias (45.09 ml) and limits of agreement (35.52 ml). Interobserver variability was lowest for 3D echocardiography (left atrium 7.2 ml, 11%, right atrium 8.7 ml, 16%). CONCLUSIONS: Freehand 3D echocardiography using the line of intersection display for guidance of image positioning and a polyhedral surface reconstruction algorithm is a valid, accurate, reproducible method for determining left and right atrial volume in humans that is comparable to magnetic resonance imaging and is superior to current ID and 2D echocardiographic techniques.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1053/euje.2000.0010

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 196

Metadata

Authors
KELLER, A., GOPAL, A., & KING, D.
Venue
European Journal of Echocardiography
Published
2000-03
Volume
1
Issue
1
Pages
55-65
ISSN
1525-2167 (ISSN-L)
OpenAlex
W2148754242
Cited by
196
References
1
FWCI
0.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Left and Right Atrial Volume by Freehand Three-dimensional Echocardiography: In Vivo Validation Using Magnetic Resonance Imaging. https://app.cochat.ai/papers/10.1053/euje.2000.0010
The paper
KELLER, A., GOPAL, A., & KING, D. (2000). Left and Right Atrial Volume by Freehand Three-dimensional Echocardiography: In Vivo Validation Using Magnetic Resonance Imaging. European Journal of Echocardiography. https://doi.org/10.1053/euje.2000.0010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.