CoChat

Is electrical storm in ICD patients the sign of a dying heart? Outcome of patients with clusters of ventricular tachyarrhythmias

Open access
Greene, M · 2000 · Europace
Cited by 140

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Electrical storm in patients with implanted cardioverter defibrillators (ICDs) is purported to carry an ominous prognosis. METHODS AND RESULTS: We retrospectively compared 40 patients with electrical storm (defined as three or more episodes of ventricular arrhythmia requiring ICD therapy in a 24 h period) with those only having isolated appropriate ICD therapy (n=57) and with patients having no or only inappropriate ICD therapy (n=125). All patients received ICDs for documented sustained VT or VF. There was no significant difference in age, sex, ejection fraction, total follow-up time, or underlying heart disease between any of the three groups. Patients who had electrical storm received their first appropriate ICD therapy 275 +/- 369 days post-implant (35% had storm as their first event) with storm occurring an average of 599 +/- 710 days post-implant. Patients had 1.5 +/- 1.0 storms in total (median= 1), with 55 +/- 91 episodes per storm. There were no significant differences in actuarial survival at 5-year follow-up between the three groups. Eighty percent of storm patients were alive 5 years post-implant. CONCLUSION: Storm is a common occurrence in ICD patients, can occur at any time during the follow-up period, and does not independently confer increased mortality.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1053/eupc.2000.0104

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 140

Metadata

Authors
Greene, M.
Venue
Europace
Published
2000-07
Volume
2
Issue
3
Pages
263-269
ISSN
1099-5129 (ISSN-L)
OpenAlex
W2136518010
Cited by
140
References
1
FWCI
1.41
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.