Imprecision of Urinary Iothalamate Clearance as a Gold-Standard Measure of GFR Decreases the Diagnostic Accuracy of Kidney Function Estimating Equations
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background Evaluating the accuracy of estimated glomerular filtration rate (eGFR) derived from serum creatinine (SCr) and serum cystatin C (SCysC) equations requires gold standard measures of GFR. However, the influence of imprecise measured GFRs (mGFRs) on estimates of equation error is unknown. Study Design Diagnostic test study Setting & Participants 1995 participants from the Modification of Diet in Renal Disease (MDRD) Study and African American Study of Kidney Disease (AASK) with at least two baseline mGFRs from125I-iothalamate urinary clearances, one standardized Scr value, and one SCysC value. Index Tests eGFRs calculated from the 4-variable IDMS-traceable MDRD Study equation, the CKD-EPI SCysC equation, the CKD-EPI SCr-SCysC equation, and mGFRs collected from another pre-randomization visit Reference Tests A single reference mGFR, average of two, and average of three mGFRs; additional analysis limited to consistent mGFRs (difference fl 25% from the reference mGFR) Results We found that mGFRs had stable means but substantial variability across visits. Of all the mGFRs collected a mean of 62 days apart from the reference visit, 8.0% fell outside 30% of the single reference mGFR (1-P30). The estimation equations were less accurate as 12.1%, 17.1% and 8.3% of the eGFR from MDRD Study, CKD-EPI SCysC, and CKD-EPI SCr-SCysC equations fell outside 30% of the same gold standard (1-P30). However, improving the precision of the reference test from a single mGFR to the average of three consistent mGFRs reduced these error estimates (1-P30) to 8.0%, 12.5% and 3.9% respectively. Limitations Study population limited to those with CKD. Conclusions Imprecision in gold standard measures of GFR contribute to an appreciable proportion of the cases where estimated and measured GFR differs by more than 30%. Reducing and quantifying errors in gold standard measurements of GFR is critical to fully estimating the accuracy of GFR estimates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Klahr, S., Levey, A. S., Beck, G. J., Caggiula, A. W., Hunsicker, L., Kusek, J. W., & Striker, G. (1994) · New England Journal of Medicine · doi:10.1056/nejm199403313301301 · Cited by 2,328
Self-citation
Cited by
KDIGO 2024 clinical practice guideline for the evaluation and management of chronic kidney disease
Stevens, P. E., Ahmed, S. B., Carrero, J. J., Foster, B., Francis, A., Hall, R. K., Herrington, W. G., Hill, G., Inker, L. A., Kazancıoğlu, R., et al. (2024) · Kidney International · doi:10.1016/j.kint.2023.10.018 · Cited by 8,530
Estimating glomerular filtration rate from serum creatinine and cystatin C
Inker, L. A., Schmid, C. H., Tighiouart, H., Eckfeldt, J. H., Feldman, H. I., Greene, T., Kusek, J. W., Manzi, J., Van Lente, F., Zhang, Y. L., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1114248 · Cited by 4,102
Self-citationChapter 1: Definition and classification of CKD
(2013) · Kidney International Supplements · doi:10.1038/kisup.2012.64 · Cited by 1,110
Glomerular hyperfiltration in diabetes: mechanisms, clinical significance, and treatment
Tonneijck, L., Muskiet, M. H. A., Smits, M. M., van Bommel, E. J., Heerspink, H. J. L., van Raalte, D. H., & Joles, J. A. (2017) · Journal of the American Society of Nephrology · doi:10.1681/asn.2016060666 · Cited by 887
“10,13 Identi fi cation of hyper fi l-tration in clinical practice and systematic studies is complicated by intra-and interday GFR fl uctuations, 14,15 and the inaccuracy of available serum creatinine – based GFR estimates.”
Delgado, C., Baweja, M., Crews, D. C., Eneanya, N. D., Gadegbeku, C. A., Inker, L. A., Mendu, M. L., Miller, W. G., Moxey-Mims, M. M., Roberts, G. V., et al. (2022) · American Journal of Kidney Diseases · doi:10.1053/j.ajkd.2021.08.003 · Cited by 783
“Careful consideration for individual evaluations should not rely on a single result for clinical decision making but should be informed by trends in eGFR values (which may require more frequent testing) and other clinical information, including confirmatory testing to determine a more reliable baseline function using…”
BackgroundMethodResultInfluential
Metadata
- Authors
- Kwong, Y.-T. (., Stevens, L. A., Selvin, E., Zhang, Y. (., Greene, T., Van Lente, F., Levey, A. S., & Coresh, J.
- Venue
- American Journal of Kidney Diseases
- Publisher
- Elsevier BV
- Published
- 2010-07
- Volume
- 56
- Issue
- 1
- Pages
- 39-49
- ISSN
- 0272-6386 (ISSN-L)
- OpenAlex
- W2128168657
- Cited by
- 130
- References
- 1
- FWCI
- 12.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Imprecision of Urinary Iothalamate Clearance as a Gold-Standard Measure of GFR Decreases the Diagnostic Accuracy of Kidney Function Estimating Equations. https://app.cochat.ai/papers/10.1053/j.ajkd.2010.02.347
- The paper
- Kwong, Y.-T. (., Stevens, L. A., Selvin, E., Zhang, Y. (., Greene, T., Van Lente, F., Levey, A. S., & Coresh, J. (2010). Imprecision of Urinary Iothalamate Clearance as a Gold-Standard Measure of GFR Decreases the Diagnostic Accuracy of Kidney Function Estimating Equations. American Journal of Kidney Diseases. https://doi.org/10.1053/j.ajkd.2010.02.347
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.