Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 172

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Narrow-Band Imaging for Detection of Neoplasia at Colonoscopy: A Meta-analysis of Data From Individual Patients in Randomized Controlled Trials

Atkinson, Nathan S.S., Ket, Shara, Bassett, Paul, Aponte, Diego, De Aguiar, Silvia, Gupta, Neil, Horimatsu, Takahiro, Ikematsu, Hiroaki, Inoue, Takuya, Kaltenbach, Tonya, Leung, Wai Keung, Matsuda, Takahisa, Paggi, Silvia, Radaelli, Franco, Rastogi, Amit, Rex, Douglas K., Sabbagh, Luis C., Saito, Yutaka, Sano, Yasushi, Saracco, Giorgio M., Saunders, Brian P., Senore, Carlo, Soetikno, Roy, Vemulapalli, Krishna C., Jairath, Vipul, East, James E. · 2019 · Gastroenterology

Abstract

BACKGROUND & AIMS Adenoma detection rate (ADR) is an important quality assurance measure for colonoscopy. Some studies suggest that narrow band imaging (NBI) may be more effective at detection of adenomas than white-light endoscopy (WLE) when bowel preparation is optimal. We conducted a meta-analysis of data from individual patients in randomized controlled trials that compared the efficacy of NBI to WLE in detection of adenomas. METHODS We searched MEDLINE, EMBASE, and Cochrane library databases, through April 2017, for randomized controlled trials that assessed detection of colon polyps by high-definition WLE vs NBI and from which data on individual patients was available. The primary outcome measure was ADR adjusted for bowel preparation quality. Multilevel regression models were used with patients nested within trials, and trial included as a random effect. RESULTS We collected data from 11 trials, comprising 4491 patients and 6636 polyps detected. Adenomas were detected in 952/2251 (42.3%) participants examined by WLE vs 1011/2239 (45.2%) participants examined by NBI (unadjusted odds ratio [OR] for detection of adenoma by WLE vs NBI, 1.14; 95% CI, 1.01-1.29; P=.04). NBI outperformed WLE only when bowel preparation was best: adequate preparation OR, 1.07 (95% CI, 0.92-1.24; P=.38) vs best preparation OR, 1.30 (95% CI, 1.04-1.62; P=.02). Second-generation bright NBI had a better ADR than WLE (second-generation NBI OR, 1.28; 95% CI, 1.05-1.56; P=.02), whereas first-generation NBI did not. NBI detected more non-adenomatous polyps than WLE (OR, 1.24; 95% CI, 1.06-1.44; P=.008) and flat polyps than WLE (OR, 1.24; 95% CI, 1.02-1.51; P=.03). CONCLUSIONS In a meta-analysis of data from individual patients in randomized controlled trials, we found NBI to have a higher ADR than WLE, and that this effect is greater when bowel preparation is optimal.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1053/j.gastro.2019.04.014

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 172

Metadata

Authors
Atkinson, N. S. S., Ket, S., Bassett, P., Aponte, D., De Aguiar, S., Gupta, N., Horimatsu, T., Ikematsu, H., Inoue, T., Kaltenbach, T., Leung, W. K., Matsuda, T., Paggi, S., Radaelli, F., Rastogi, A., Rex, D. K., Sabbagh, L. C., Saito, Y., Sano, Y., Saracco, G. M., Saunders, B. P., Senore, C., Soetikno, R., Vemulapalli, K. C., Jairath, V., & East, J. E.
Venue
Gastroenterology
Publisher
Elsevier BV
Published
2019-08
Volume
157
Issue
2
Pages
462-471
ISSN
0016-5085 (ISSN-L)
OpenAlex
W2937903160
Cited by
172
References
1
FWCI
2.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.