The DOI matches its Crossref record; 111 of the 111 references it cites were found in a registry or an index.
Noninvasive Cardiac Output Monitors: A State-of the-Art Review
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2 retracted
Mayer, J., Boldt, J., Schöllhorn, T., Röhm, K. D., Mengistu, A. M., & Suttner, S. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/ael341 · Cited by 146
RetractedMayer, J., Boldt, J., Wolf, M. W., Lang, J. K., & Suttner, S. W. (2008) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318161964d · Cited by 101
RetractedSTATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Early goal-directed therapy in the treatment of severe sepsis and septic shock
Rivers, E., Nguyen, B., Havstad, S., Ressler, J., Muzzin, A., Knoblich, B., Peterson, E., & Tomlanovich, M. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010307 · Cited by 10,743
Catheterization of the Heart in Man with Use of a Flow-Directed Balloon-Tipped Catheter
Swan, H. J. C., Ganz, W., Forrester, J., Marcus, H., Diamond, G., & Chonette, D. (1970) · New England Journal of Medicine · doi:10.1056/nejm197008272830902 · Cited by 2,137
Mortality after Fluid Bolus in African Children with Severe Infection
Maitland, K., Kiguli, S., Opoka, R. O., Engoru, C., Olupot-Olupot, P., Akech, S. O., Nyeko, R., Mtove, G., Reyburn, H., Lang, T., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1101549 · Cited by 1,592
Boyd, J. H., Forbes, J., Nakada, T.-A., Walley, K. R., & Russell, J. A. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181feeb15 · Cited by 1,517
Marik, P. E., Baram, M., & Vahid, B. (2008) · Chest · doi:10.1378/chest.07-2331 · Cited by 1,516
Self-citationCritchley, L. A. H., & Critchley, J. A. J. H. (1999) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1009982611386 · Cited by 1,325
Marik, P. E., Cavallazzi, R., Vasu, T., & Hirani, A. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a590da · Cited by 1,272
Self-citation
Cited by
Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis
Monnet, X., Marik, P., & Teboul, J.-L. (2016) · Intensive Care Medicine · doi:10.1007/s00134-015-4134-1 · Cited by 482
Self-citationLess invasive hemodynamic monitoring in critically ill patients
Teboul, J.-L., Saugel, B., Cecconi, M., De Backer, D., Hofer, C. K., Monnet, X., Perel, A., Pinsky, M. R., Reuter, D. A., Rhodes, A., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4375-7 · Cited by 328
Metadata
- Authors
- Marik, P. E.
- Venue
- Journal of Cardiothoracic and Vascular Anesthesia
- Publisher
- Elsevier BV
- Published
- 2013-02
- Volume
- 27
- Issue
- 1
- Pages
- 121-134
- ISSN
- 1053-0770 (ISSN-L)
- OpenAlex
- W2133742416
- Cited by
- 293
- References
- 111
- FWCI
- 29.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive Cardiac Output Monitors: A State-of the-Art Review. https://app.cochat.ai/papers/10.1053/j.jvca.2012.03.022
- The paper
- Marik, P. E. (2013). Noninvasive Cardiac Output Monitors: A State-of the-Art Review. Journal of Cardiothoracic and Vascular Anesthesia. https://doi.org/10.1053/j.jvca.2012.03.022
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.