CoChat

Antibody Vectors for Imaging

Open access
Olafsen, Tove, Wu, Anna M. · 2010 · Seminars in Nuclear Medicine
Cited by 223

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Non-invasive molecular imaging approaches include nuclear, optical, MRI, CT, ultrasound and photoacoustic imaging, which require accumulation of a signal delivered by a probe at the target site. Monoclonal antibodies (mAbs) are high affinity molecules that can be used for specific, high signal delivery to cell surface molecules. However, their long circulation time in blood makes them unsuitable as imaging probes. Efforts to improve antibodies pharmacokinetics without compromising affinity and specificity have been made through protein engineering. Antibody variants that differ in antigen binding sites and size have been generated and evaluated as imaging probes to target tissues of interest. Fast clearing fragments such as single-chain Fv (scFv; 25 kDa) with one antigen binding site (monovalent) demonstrated low accumulation in tumors due the low exposure time to the target. Using scFv as building block to produce larger, bivalent fragments such as scFv dimers (diabodies, 50 kDa) and scFv-fusion proteins (80 kDa minibodies and 105 kDa scFv-Fc) resulted in higher tumor accumulation due to their longer residence time in blood. Imaging studies with these fragments following radiolabeling have demonstrated excellent, high contrast images in gamma cameras and PET scanners. Several studies have also investigated antibody fragments conjugated to fluorescence (near infrared dyes), bioluminescence (luciferases) and quantum dots for optical imaging and iron oxides nanoparticles for MRI. However, these studies indicate that there are several factors that influence successful targeting and imaging. These include stability of the antibody fragment, the labeling chemistry (direct or indirect), whether critical residues are modified, the number of antigen expressed on the cell, and whether the target has a rapid recycling rate or internalizes upon binding. The preclinical data presented are compelling and it is evident that antibody-based molecular imaging tracers will play an important future role in the diagnosis and management of cancer and other diseases.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1053/j.semnuclmed.2009.12.005

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 223

Metadata

Authors
Olafsen, T., & Wu, A. M.
Venue
Seminars in Nuclear Medicine
Publisher
Elsevier BV
Published
2010-05
Volume
40
Issue
3
Pages
167-181
ISSN
0001-2998 (ISSN-L)
OpenAlex
W2084108774
Cited by
223
References
3
FWCI
18.08
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.