The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Evaluation of a virtual reality simulator for arthroscopy skills development
Abstract
We evaluated a virtual reality shoulder arthroscopy simulator using a standardized skills-assessment algorithm in 3 specific groups with various degrees of surgical expertise. The simulator (Mentice Corp, Gothenberg, Sweden) consists of a computer-based, dual-force feedback system with video monitor. Modeled structures include cartilage, labrum, ligaments, biceps tendon, and rotator cuff. The study included 3 groups of volunteers: group 1, medical students interviewing for orthopaedic residency (n = 35); group 2, orthopaedic residents interviewing for sports medicine fellowship (n = 22); and group 3, experienced faculty at a shoulder surgery course (n = 21). Data were collected anonymously and subjects completed a standardized test protocol designed to assess accuracy and efficiency. Subjects used the probe to "touch" a sphere that appeared at various locations within the joint (11 positions total). The sphere changed location immediately on contact with the tip of the probe. The following parameters were calculated by the computer: time (from touching the first ball until touching the eleventh ball), path ratio (percent of measured path length relative to the ideal path), collisions (number of times the probe / arthroscope contacted any tissue), and injuries (collisions beyond a threshold force). Test time and path ratio differed significantly as a function of surgical experience. There was no significant difference in probe collisions between the groups. Arthroscope collisions and injuries averaged 2 or less in all of the groups. There was significant correlation between path ratio and time to complete the test in groups 1 and 2 (r =.527 and r =.827, respectively, P <.001), but not in group 3 (r =.376, P =.10). There was essentially normal distribution of time performance in groups 1 and 2. Time was shorter and more consistent in group 3, suggesting greater consistency in the experienced surgeons. These data suggest that this arthroscopy simulator facilitates discrimination of arthroscopic skills. Computer-based simulation technology provides a major opportunity for surgical skills development without morbidity and operating room inefficiency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cognitive Apprenticeship: Teaching the Crafts of Reading, Writing, and Mathematics
Collins, A., Brown, J. S., & Newman, S. E. (2018) · Knowing, Learning, and Instruction · doi:10.4324/9781315044408-14 · Cited by 3,674
Cited by
Effectiveness of Virtual Reality Training in Orthopaedic Surgery
Aïm, F., Lonjon, G., Hannouche, D., & Nizard, R. (2016) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1016/j.arthro.2015.07.023 · Cited by 257
(2007) · Educational Technology archive · Cited by 63
Metadata
- Authors
- Pedowitz, R. A., Esch, J., & Snyder, S.
- Venue
- Arthroscopy: The Journal of Arthroscopic & Related Surgery
- Publisher
- Elsevier BV
- Published
- 2002-07
- Volume
- 18
- Issue
- 6
- Pages
- 1-6
- ISSN
- 0749-8063 (ISSN-L)
- OpenAlex
- W2137290953
- Cited by
- 170
- References
- 1
- FWCI
- 2.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of a virtual reality simulator for arthroscopy skills development. https://app.cochat.ai/papers/10.1053/jars.2002.33791
- The paper
- Pedowitz, R. A., Esch, J., & Snyder, S. (2002). Evaluation of a virtual reality simulator for arthroscopy skills development. Arthroscopy: The Journal of Arthroscopic & Related Surgery. https://doi.org/10.1053/jars.2002.33791
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.