CoChat

The effect of soft-tissue graft fixation in anterior cruciate ligament reconstruction on graft-tunnel motion under anterior tibial loading

Tsuda, Eiichi, Fukuda, Yukihisa, Loh, John C., Debski, Richard E., Fu, Freddie H., Woo, Savio L-Y. · 2002 · Arthroscopy: The Journal of Arthroscopic & Related Surgery
Cited by 93

The DOI matches its Crossref record.

Abstract

PURPOSE: To compare the motion of an anterior cruciate ligament (ACL) replacement graft within the femoral bone tunnel (graft- tunnel motion) when a soft-tissue graft is secured either by a titanium button and polyester tape (EndoButton fixation; Acufex, Smith & Nephew, Mansfield, MA) or by a biodegradable interference screw (Biointerference fixation; Endo-fix; Acufex, Smith & Nephew) An additional purpose was to evaluate the effect of the graft-tunnel motion on the kinematics of ACL-reconstructed knees and in situ force of the ACL replacement graft. TYPE OF STUDY: Biomechanical experiment using an in vitro animal model. METHODS: ACL reconstruction with a flexor tendon autograft was performed in 8 cadaveric knees of skeletally mature goats. The knee kinematics and the in situ force in the ACL replacement graft in response to anterior tibial loads were evaluated using the robotic/universal force-moment sensor testing system. The longitudinal and transverse graft-tunnel motion during anterior tibial loading was determined based on radiographic measurements parallel and perpendicular to the femoral bone tunnel, respectively. RESULTS: In response to an anterior tibial load of 100 N, the longitudinal graft-tunnel motion for EndoButton fixation and Biointerference fixation was 0.8 +/- 0.4 mm and 0.2 +/- 0.1 mm, respectively (P <.05), whereas the transverse graft-tunnel motion was 0.5 +/- 0.2 mm and 0.1 +/- 0.1 mm, respectively (P <.05). Furthermore, the anterior tibial translation for EndoButton fixation (5.3 +/- 1.2 mm) was also significantly larger than that for Biointerference fixation (4.2 +/- 0.9 mm) (P <.05). With both fixations, however, no significant difference between the in situ forces in the ACL replacement graft and that in the intact ACL could be detected. CONCLUSIONS: EndoButton fixation of a soft-tissue graft via an elastic material resulted in significantly larger graft-tunnel motion, and consequently, greater anterior knee laxity compared with more rigid fixation using an interference screw closer to the intra-articular entrance of the bone tunnel. In terms of force distribution, the ACL replacement graft in both fixations still functioned as a primary restraint to an anterior tibial load close to the intact ACL.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1053/jars.2002.36112

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 93

Metadata

Authors
Tsuda, E., Fukuda, Y., Loh, J. C., Debski, R. E., Fu, F. H., & Woo, S. L.-Y.
Venue
Arthroscopy: The Journal of Arthroscopic & Related Surgery
Publisher
Elsevier BV
Published
2002-11
Volume
18
Issue
9
Pages
960-967
ISSN
0749-8063 (ISSN-L)
OpenAlex
W1986826203
Cited by
93
References
0
FWCI
4.54
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The effect of soft-tissue graft fixation in anterior cruciate ligament reconstruction on graft-tunnel motion under anterior tibial loading. https://app.cochat.ai/papers/10.1053/jars.2002.36112
The paper
Tsuda, E., Fukuda, Y., Loh, J. C., Debski, R. E., Fu, F. H., & Woo, S. L.-Y. (2002). The effect of soft-tissue graft fixation in anterior cruciate ligament reconstruction on graft-tunnel motion under anterior tibial loading. Arthroscopy: The Journal of Arthroscopic & Related Surgery. https://doi.org/10.1053/jars.2002.36112

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.