The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Arthroscopic biceps tenodesis: A new technique using bioabsorbable interference screw fixation
Abstract
PURPOSE: To report a new technique of arthroscopic biceps tenodesis using bioabsorbable interference screw fixation and the early results. TYPE OF STUDY: Prospective, nonrandomized study. TECHNIQUE: The principle of arthroscopic biceps tenodesis is simple: after biceps tenotomy, the tendon is exteriorized and doubled on a suture; the biceps tendon is then pulled into a humeral socket (7 or 8 mm x 25 mm) drilled at the top of the bicipital groove, and fixed using a bioabsorbable interference screw (8 or 9 mm x 25 mm) under arthroscopic control. PATIENTS: 43 patients treated with this technique between 1997 and 1999 were followed-up for at least 1 year. The technique was indicated in 3 clinical situations: (1) with arthroscopic cuff repair (3 cases), (2) in case of isolated pathology of the biceps tendon with an intact cuff (6 cases), and (3) as an alternative to biceps tenotomy in patients with massive, degenerative and irreparable cuff tears (34 cases). The biceps pathology was tenosynovitis (4 cases), prerupture (15 cases), subluxation (11 cases), and luxation (13 cases). RESULTS: The absolute Constant score improved from 43 points preoperatively to 79 points at review (P <.005). There was no loss of elbow movement and biceps strength was 90% of the strength of the other side. Two patients, operated on early in the series, presented with a rupture of the tenodesis. In both cases the bicipital tendon was very friable and the diameter of the screw proved to be insufficient (7 mm). No neurologic or vascular complications occurred. CONCLUSIONS: Arthroscopic biceps tenodesis using bioabsorbable screw fixation is technically possible and gives good clinical results. This technique can be used in cases of isolated pathologic biceps tendon or a cuff tear. A very thin, fragile, almost ruptured biceps tendon is the technical limit of this arthroscopic technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Orthopaedic applications for PLA‐PGA biodegradable polymers
Athanasiou, K., Agrawal, C., Barber, F., & Burkhart, S. (1998) · Arthroscopy · doi:10.1016/s0749-8063(98)70099-4 · Cited by 487
Analysis of a Semitendinosus Autograft in a Rabbit Model
Blickenstaff, K. R., Grana, W. A., & Egle, D. (1997) · The American Journal of Sports Medicine · doi:10.1177/036354659702500420 · Cited by 164
Cited by
Arthroscopic Repair of Full-Thickness Tears of the Supraspinatus: Does the Tendon Really Heal?
Boileau, P. (2005) · The Journal of Bone and Joint Surgery (American) · doi:10.2106/jbjs.d.02035 · Cited by 1,248
Self-citation
Metadata
- Authors
- Boileau, P., Krishnan, S. G., Coste, J.-S., & Walch, G.
- Venue
- Arthroscopy: The Journal of Arthroscopic & Related Surgery
- Publisher
- Elsevier BV
- Published
- 2002-11
- Volume
- 18
- Issue
- 9
- Pages
- 1002-1012
- ISSN
- 0749-8063 (ISSN-L)
- OpenAlex
- W2097843668
- Cited by
- 325
- References
- 2
- FWCI
- 9.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Arthroscopic biceps tenodesis: A new technique using bioabsorbable interference screw fixation. https://app.cochat.ai/papers/10.1053/jars.2002.36488
- The paper
- Boileau, P., Krishnan, S. G., Coste, J.-S., & Walch, G. (2002). Arthroscopic biceps tenodesis: A new technique using bioabsorbable interference screw fixation. Arthroscopy: The Journal of Arthroscopic & Related Surgery. https://doi.org/10.1053/jars.2002.36488
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.