The DOI matches its Crossref record.
The arthroscopic implantation of autologous chondrocytes for the treatment of full-thickness cartilage defects of the knee joint
Abstract
Autologous chondrocyte implantation is an established option for the treatment of full-thickness cartilage defects of the knee. Open implantation has a high morbidity. On a resorbable polymer fleece, autologous chondrocytes can be implanted arthroscopically. Transosseous anchoring assures high initial stability of the implant. Tibial defects can be addressed. The arthroscopic technique for the implantation of autologous chondrocytes eliminates a substantial amount of the side effects known to occur after open autologous chondrocyte implantation procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cell-based tissue engineering strategies used in the clinical repair of articular cartilage
Huang, B. J., Hu, J. C., & Athanasiou, K. A. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.04.018 · Cited by 393
Cartilage repair: generations of autologous chondrocyte transplantation
Marlovits, S., Zeller, P., Singer, P., Resinger, C., & Vécsei, V. (2006) · European Journal of Radiology · doi:10.1016/j.ejrad.2005.08.009 · Cited by 388
BRITTBERG, M., PETERSON, L., SJÖGREN-JANSSON, E., TALLHEDEN, T., & LINDAHL, A. (2003) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200300003-00017 · Cited by 386
Ringe, J., Strassburg, S., Neumann, K., Endres, M., Notter, M., Burmester, G., Kaps, C., & Sittinger, M. (2007) · Journal of Cellular Biochemistry · doi:10.1002/jcb.21172 · Cited by 371
Self-citationWilke, M. M., Nydam, D. V., & Nixon, A. J. (2007) · Journal of Orthopaedic Research · doi:10.1002/jor.20382 · Cited by 327
Sasagawa, T., Shimizu, T., Sekiya, S., Haraguchi, Y., Yamato, M., Sawa, Y., & Okano, T. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.11.036 · Cited by 301
A clinical review of cartilage repair techniques
Smith, G. D., Knutsen, G., & Richardson, J. B. (2005) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.87b4.15971 · Cited by 286
Niemeyer, P., Pestka, J. M., Kreuz, P. C., Erggelet, C., Schmal, H., Suedkamp, N. P., & Steinwachs, M. (2008) · The American Journal of Sports Medicine · doi:10.1177/0363546508322131 · Cited by 278
Self-citationAutologous chondrocyte implantation—Technique and long-term follow-up
Brittberg, M. (2008) · Injury · doi:10.1016/j.injury.2008.01.040 · Cited by 265
Ossendorf, C., Kaps, C., Kreuz, P. C., Burmester, G. R., Sittinger, M., & Erggelet, C. (2007) · Arthritis Research & Therapy · doi:10.1186/ar2180 · Cited by 262
Self-citationCell delivery therapeutics for musculoskeletal regeneration☆
Nöth, U., Rackwitz, L., Steinert, A. F., & Tuan, R. S. (2010) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2010.04.004 · Cited by 119
Metadata
- Authors
- Erggelet, C., Sittinger, M., & Lahm, A.
- Venue
- Arthroscopy: The Journal of Arthroscopic & Related Surgery
- Publisher
- Elsevier BV
- Published
- 2003-01
- Volume
- 19
- Issue
- 1
- Pages
- 108-110
- ISSN
- 0749-8063 (ISSN-L)
- OpenAlex
- W2077984765
- Cited by
- 206
- References
- 0
- FWCI
- 8.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.