Comparison of Peritoneal Fluid and Peripheral Blood pH, Bicarbonate, Glucose, and Lactate Concentration as a Diagnostic Tool for Septic Peritonitis in Dogs and Cats
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Objective—To establish a reliable diagnostic tool for septic peritonitis in dogs and cats using pH, bicarbonate, lactate, and glucose concentrations in peritoneal fluid and venous blood. Study Design—Prospective clinical study. Animals—Eighteen dogs and 12 cats with peritoneal effusion. Methods—pH, bicarbonate, electrolyte, lactate, and glucose concentrations were measured on 1‐ to 2‐mL samples of venous blood and peritoneal fluid collected at admission. The concentration difference between blood and peritoneal fluid for pH, bicarbonate, glucose, and lactate concentrations were calculated by subtracting the peritoneal fluid concentration from the blood concentration. Peritoneal fluid was submitted for cytologic examination and bacterial culture. Peritonitis was classified as septic or nonseptic based on cytology and bacterial culture results. Results—In dogs, with septic effusion, peritoneal fluid glucose concentration was always lower than the blood glucose concentration. A blood‐to‐fluid glucose (BFG) difference > 20 mg/dL was 100% sensitive and 100% specific for the diagnosis of septic peritoneal effusion in dogs. In 7 dogs in which it was evaluated, a blood‐to‐fluid lactate (BFL) difference < −2.0 mmol/L was also 100% sensitive and specific for a diagnosis of septic peritoneal effusion. In cats, the BFG difference was 86% sensitive and 100% specific for a diagnosis of septic peritonitis. In dogs and cats, the BFG difference was more accurate for a diagnosis of septic peritonitis than peritoneal fluid glucose concentration alone. Conclusions—A concentration difference > 20 mg/dL between blood and peritoneal fluid glucose concentration provides a rapid and reliable means to differentiate a septic peritoneal effusion from a nonseptic peritoneal effusion in dogs and cats. Clinical Relevance—The difference between blood and peritoneal fluid glucose concentrations should be used as a more reliable diagnostic indicator of septic peritoneal effusion than peritoneal fluid glucose concentration alone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Veterinary Epidemiology: Principles and Methods
Мартин, С., Meek, A. H., & Willeberg, P. W. (1987) · VTechWorks (Virginia Tech) · Cited by 983
Frith, C. (1997) · Medical Entomology and Zoology · Cited by 624
Simmen, H.-P., & Blaser, J. (1993) · The American Journal of Surgery · doi:10.1016/s0002-9610(05)80576-8 · Cited by 174
The Diagnosis of Bacterial Peritonitis: Comparison of Ph, Lactate Concentration and Leukocyte Count
García–Tsao, G., Conn, H. O., & Lerner, E. (1985) · Hepatology · doi:10.1002/hep.1840050119 · Cited by 108
White Count, Ph and Lactate in Ascites in the Diagnosis of Spontaneous Bacterial Peritonitis
Yang, C., Liaw, Y., Chu, C., & Sheen, I. (1985) · Hepatology · doi:10.1002/hep.1840050118 · Cited by 77
Cited by
Powering implantable and ingestible electronics
Yang, S., Sencadas, V., You, S. S., Jia, N. Z., Srinivasan, S. S., Huang, H., Ahmed, A. E., Liang, J. Y., & Traverso, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202009289 · Cited by 183
Lactate: physiology and clinical utility
Allen, S. E., & Holm, J. L. (2008) · Journal of Veterinary Emergency and Critical Care · doi:10.1111/j.1476-4431.2008.00286.x · Cited by 163
“peritoneal effusion in order to diagnose septic peritonitis.(48) A blood-to-fluid glucose difference of 420 mg/dL was found to be 100% sensitive and 100% specific for the diagnosis of septic effusion in dogs and 86%”
BackgroundConvergence of biological nitration and nitrosation via symmetrical nitrous anhydride
Vitturi, D. A., Minarrieta, L., Salvatore, S. R., Postlethwait, E. M., Fazzari, M., Ferrer-Sueta, G., Lancaster, J. R., Freeman, B. A., & Schopfer, F. J. (2015) · Nature Chemical Biology · doi:10.1038/nchembio.1814 · Cited by 65
Metadata
- Authors
- Bonczynski, J. J., Ludwig, L. L., Barton, L. J., Loar, A., & Peterson, M. E.
- Venue
- Veterinary Surgery
- Publisher
- Wiley
- Published
- 2003-03
- Volume
- 32
- Issue
- 2
- Pages
- 161-166
- ISSN
- 0161-3499 (ISSN-L)
- 1532-950X
- OpenAlex
- W1980076389
- Cited by
- 190
- References
- 5
- FWCI
- 1.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.