Therapeutic endoscopic ultrasound: European Society of Gastrointestinal Endoscopy (ESGE) Technical Review
Open accessThe DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Main Recommendations: 1 ESGE recommends a prolonged course of a prophylactic broad-spectrum antibiotic in patients with ascites who are undergoing therapeutic endoscopic ultrasound (EUS) procedures.Strong recommendation, low quality evidence. 2 ESGE recommends placement of partially or fully covered self-expandable metal stents during EUS-guided hepaticogastrostomy for biliary drainage in malignant disease.Strong recommendation, moderate quality evidence. 3 ESGE recommends EUS-guided pancreatic duct (PD) drainage should only be performed in high volume expert centers, owing to the complexity of this technique and the high risk of adverse events.Strong recommendation, low quality evidence. 4 ESGE recommends a stepwise approach to EUS-guided PD drainage in patients with favorable anatomy, starting with rendezvous-assisted endoscopic retrograde pancreatography (RV-ERP), followed by antegrade or transmural drainage only when RV-ERP fails or is not feasible.Strong recommendation, low quality evidence. 5 ESGE suggests performing transduodenal EUS-guided gallbladder drainage with a lumen-apposing metal stent (LAMS), rather than using the transgastric route, as this may reduce the risk of stent dysfunction.Weak recommendation, low quality evidence. 6 ESGE recommends using saline instillation for small-bowel distension during EUS-guided gastroenterostomy.Strong recommendation, low quality evidence. 7 ESGE recommends the use of saline instillation with a 19G needle and an electrocautery-enhanced LAMS for EUS-directed transgastric endoscopic retrograde cholangiopancreatography (EDGE) procedures.Strong recommendation, low quality evidence. 8 ESGE recommends the use of either 15- or 20-mm LAMSs for EDGE, with a preference for 20-mm LAMSs when considering a same-session ERCP.Strong recommendation, low quality evidence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GRADE guidelines: 1. Introduction—GRADE evidence profiles and summary of findings tables
Guyatt, G., Oxman, A. D., Akl, E. A., Kunz, R., Vist, G., Brozek, J., Norris, S., Falck-Ytter, Y., Glasziou, P., & deBeer, H. (2011) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2010.04.026 · Cited by 10,681
Berríos-Torres, S. I., Umscheid, C. A., Bratzler, D. W., Leas, B., Stone, E. C., Kelz, R. R., Reinke, C. E., Morgan, S., Solomkin, J. S., Mazuski, J. E., et al. (2017) · JAMA Surgery · doi:10.1001/jamasurg.2017.0904 · Cited by 3,569 · cited 1×
“Until more data become available, it is recommended that a single dose of intravenous antibiotics is administered when a transmural therapeutic procedure is performed, analogous to surgical and interventional radiology protocols [16, 17].”
Endoscopic versus Surgical Drainage of the Pancreatic Duct in Chronic Pancreatitis
Cahen, D. L., Gouma, D. J., Nio, Y., Rauws, E. A. J., Boermeester, M. A., Busch, O. R., Stoker, J., Laméris, J. S., Dijkgraaf, M. G. W., Huibregtse, K., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa060610 · Cited by 847
Arvanitakis, M., Dumonceau, J.-M., Albert, J., Badaoui, A., Bali, M., Barthet, M., Besselink, M., Deviere, J., Oliveira Ferreira, A., Gyökeres, T., et al. (2018) · Endoscopy · doi:10.1055/a-0588-5365 · Cited by 538 · cited 1×
“EUS-guided management of fluid collections in acute necrotizing pancreatitis has been discussed in a previous ESGE guideline [2].”
Self-citationTherapeutic endoscopic ultrasound: European Society of Gastrointestinal Endoscopy (ESGE) Guideline
van der Merwe, S. W., van Wanrooij, R. L. J., Bronswijk, M., Everett, S., Lakhtakia, S., Rimbas, M., Hucl, T., Kunda, R., Badaoui, A., Law, R., et al. (2022) · Endoscopy · doi:10.1055/a-1717-1391 · Cited by 506
Self-citationDumonceau, J.-M., Delhaye, M., Tringali, A., Arvanitakis, M., Sanchez-Yague, A., Vaysse, T., Aithal, G., Anderloni, A., Bruno, M., Cantú, P., et al. (2019) · Endoscopy · doi:10.1055/a-0822-0832 · Cited by 402
Self-citationPark, D. H., Jang, J. W., Lee, S. S., Seo, D.-W., Lee, S. K., & Kim, M.-H. (2011) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2011.07.054 · Cited by 337 · cited 1×
“A coaxial cystotome is preferred over a needle-knife because the latter has been identified as a risk factor for AEs in EUS-BD [25].”
Teoh, A. Y. B., Kitano, M., Itoi, T., Pérez-Miranda, M., Ogura, T., Chan, S. M., Serna-Higuera, C., Omoto, S., Torres-Yuste, R., Tsuichiya, T., et al. (2020) · Gut · doi:10.1136/gutjnl-2019-319996 · Cited by 305 · cited 1×
“Several landmark papers have based their selection of LAMS diameter on the size of the gallbladder stones to allow for stone evacuation following placement: when stones are smaller than 10mm, a 10-mm LAMS would suffice; when stones are larger than 10mm, a 15-mm LAMS, but no larger, should be considered [84, 85, 103].”
Self-citationJang, J. W., Lee, S. S., Song, T. J., Hyun, Y. S., Park, D. H., Seo, D., Lee, S., Kim, M., & Yun, S. (2012) · Gastroenterology · doi:10.1053/j.gastro.2011.12.051 · Cited by 255
Dollhopf, M., Larghi, A., Will, U., Rimbaş, M., Anderloni, A., Sanchez-Yague, A., Teoh, A. Y. B., & Kunda, R. (2017) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2017.02.027 · Cited by 178 · cited 2×
“Transduodenal access is usually preferred over transgastric EUS-GBD, as antral LAMS placement has been associated with more symptom recurrence owing to food impaction and a higher risk of a buried LAMS [96, 98, 100].”
Self-citation
Metadata
- Authors
- van Wanrooij, R. L. J., Bronswijk, M., Kunda, R., Everett, S. M., Lakhtakia, S., Rimbas, M., Hucl, T., Badaoui, A., Law, R., Arcidiacono, P. G., Larghi, A., Giovannini, M., Khashab, M. A., Binmoeller, K. F., Barthet, M., Pérez-Miranda, M., van Hooft, J. E., & van der Merwe, S. W.
- Venue
- Endoscopy
- Publisher
- Georg Thieme Verlag KG
- Published
- 2022-02-03
- Volume
- 54
- Issue
- 03
- Pages
- 310-332
- ISSN
- 0013-726X (ISSN-L)
- 1438-8812
- OpenAlex
- W4210552118
- Cited by
- 184
- References
- 37
- FWCI
- 20.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Therapeutic endoscopic ultrasound: European Society of Gastrointestinal Endoscopy (ESGE) Technical Review. https://app.cochat.ai/papers/10.1055/a-1738-6780
- The paper
- van Wanrooij, R. L. J., Bronswijk, M., Kunda, R., Everett, S. M., Lakhtakia, S., Rimbas, M., Hucl, T., Badaoui, A., Law, R., Arcidiacono, P. G., Larghi, A., Giovannini, M., Khashab, M. A., Binmoeller, K. F., Barthet, M., Pérez-Miranda, M., van Hooft, J. E., & van der Merwe, S. W. (2022). Therapeutic endoscopic ultrasound: European Society of Gastrointestinal Endoscopy (ESGE) Technical Review. Endoscopy. https://doi.org/10.1055/a-1738-6780
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.