Measurement of Gastric Emptying Using a 13C-octanoic Acid Breath Test with Wagner-Nelson Analysis and Scintigraphy in Type 2 Diabetes

Trahair, Laurence G, Nauck, Michael A, Wu, Tongzhi, Stevens, Julie E, Buttfield, Madeline D, Hatzinikolas, Seva, Pham, Hung, Meier, Juris J, Rayner, Christopher K, Horowitz, Michael, Jones, Karen L · 2022 · Experimental and Clinical Endocrinology & Diabetes
Cited by 20

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Introduction Breath tests utilising 13C-labelled substrates for the assessment of gastric emptying have been applied widely. Wagner-Nelson analysis is a pharmacokinetic model that can be utilised to generate a gastric emptying curve from the % 13CO2 measured in breath samples. We compared Wagner-Nelson analysis with (i) scintigraphy and (ii) conventional breath test modelling to quantify gastric emptying in type 2 diabetes. Methods Thirteen patients (age 68.1±1.5 years, body mass index 31.0±0.9 kg/m2, HbA1c 6.3±0.2%) consumed a mashed potato meal comprising 65 g powdered potato, 20 g glucose, 250 ml water, an egg yolk labelled with 100 μL 13C-octanoic acid and 20MBq 99mTc-calcium phytate. Scintigraphic data were acquired and breath samples collected for 4 hours after the meal. Gastric emptying curves were derived based on each technique; the 50% emptying time and intragastric retention at 60 min were also calculated. Results With Wagner-Nelson analysis, a Kel=0.60 (the elimination constant) best approximated the scintigraphic gastric emptying curve. There was a relationship between the T50 calculated with scintigraphy and by both Wagner-Nelson Kel=0.60 (r2=0.45, P<0.05) and conventional analysis (r2=0.44, P<0.05). There was no significant difference in the 50% gastric emptying time for scintigraphy (68.5±4.8 min) and Wagner-Nelson Kel=0.60 (71.3±4.5 min), however, the 50% gastric emptying time calculated by conventional analysis was much greater at 164.7±6.0 min (P<0.001). Conclusion In type 2 diabetes, gastric emptying of a mashed potato meal measured using a 13C-octanoic acid breath test analysed with Wagner-Nelson Kel=0.60 closely reflects measurements obtained with scintigraphy, whereas, in absolute terms, the conventional breath test analysis does not.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/a-1784-6185

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 20

Metadata

Authors
Trahair, L. G., Nauck, M. A., Wu, T., Stevens, J. E., Buttfield, M. D., Hatzinikolas, S., Pham, H., Meier, J. J., Rayner, C. K., Horowitz, M., & Jones, K. L.
Venue
Experimental and Clinical Endocrinology & Diabetes
Published
2022-03-01
Volume
130
Issue
11
Pages
751-757
ISSN
  • 0947-7349 (ISSN-L)
  • 1439-3646
OpenAlex
W4214890924
Cited by
20
References
2
FWCI
2.83
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Measurement of Gastric Emptying Using a 13C-octanoic Acid Breath Test with Wagner-Nelson Analysis and Scintigraphy in Type 2 Diabetes. https://app.cochat.ai/papers/10.1055/a-1784-6185
The paper
Trahair, L. G., Nauck, M. A., Wu, T., Stevens, J. E., Buttfield, M. D., Hatzinikolas, S., Pham, H., Meier, J. J., Rayner, C. K., Horowitz, M., & Jones, K. L. (2022). Measurement of Gastric Emptying Using a 13C-octanoic Acid Breath Test with Wagner-Nelson Analysis and Scintigraphy in Type 2 Diabetes. Experimental and Clinical Endocrinology & Diabetes. https://doi.org/10.1055/a-1784-6185

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.