CoChat

Efficacy of a computer-aided detection system in a fecal immunochemical test-based organized colorectal cancer screening program: a randomized controlled trial (AIFIT study)

Rondonotti, Emanuele, Di Paolo, Dhanai, Rizzotto, Erik Rosa, Alvisi, Costanza, Buscarini, Elisabetta, Spadaccini, Marco, Tamanini, Giacomo, Paggi, Silvia, Amato, Arnaldo, Scardino, Giulia, Romeo, Samanta, Alicante, Saverio, Ancona, Fabio, Guido, Ennio, Marzo, Vincenza, Chicco, Fabio, Agazzi, Simona, Rosa, Cesare, Correale, Loredana, Repici, Alessandro, Hassan, Cesare, Radaelli, Franco, on behalf of the AIFIT Study Group · 2022 · Endoscopy
Cited by 66

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Background Computer-aided detection (CADe) increases adenoma detection in primary screening colonoscopy. The potential benefit of CADe in a fecal immunochemical test (FIT)-based colorectal cancer (CRC) screening program is unknown. This study assessed whether use of CADe increases the adenoma detection rate (ADR) in a FIT-based CRC screening program. Methods In a multicenter, randomized trial, FIT-positive individuals aged 50–74 years undergoing colonoscopy, were randomized (1:1) to receive high definition white-light (HDWL) colonoscopy, with or without a real-time deep-learning CADe by endoscopists with baseline ADR > 25 %. The primary outcome was ADR. Secondary outcomes were mean number of adenomas per colonoscopy (APC) and advanced adenoma detection rate (advanced-ADR). Subgroup analysis according to baseline endoscopists’ ADR (≤ 40 %, 41 %–45 %, ≥ 46 %) was also performed. Results 800 individuals (median age 61.0 years [interquartile range 55–67]; 409 men) were included: 405 underwent CADe-assisted colonoscopy and 395 underwent HDWL colonoscopy alone. ADR and APC were significantly higher in the CADe group than in the HDWL arm: ADR 53.6 % (95 %CI 48.6 %–58.5 %) vs. 45.3 % (95 %CI 40.3 %–50.45 %; RR 1.18; 95 %CI 1.03–1.36); APC 1.13 (SD 1.54) vs. 0.90 (SD 1.32; P = 0.03). No significant difference in advanced-ADR was found (18.5 % [95 %CI 14.8 %–22.6 %] vs. 15.9 % [95 %CI 12.5 %–19.9 %], respectively). An increase in ADR was observed in all endoscopist groups regardless of baseline ADR. Conclusions Incorporating CADe significantly increased ADR and APC in the framework of a FIT-based CRC screening program. The impact of CADe appeared to be consistent regardless of endoscopist baseline ADR.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/a-1849-6878

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

Metadata

Authors
Rondonotti, E., Di Paolo, D., Rizzotto, E. R., Alvisi, C., Buscarini, E., Spadaccini, M., Tamanini, G., Paggi, S., Amato, A., Scardino, G., Romeo, S., Alicante, S., Ancona, F., Guido, E., Marzo, V., Chicco, F., Agazzi, S., Rosa, C., Correale, L., Repici, A., Hassan, C., Radaelli, F., & on behalf of the AIFIT Study Group
Venue
Endoscopy
Published
2022-05-11
Volume
54
Issue
12
Pages
1171-1179
ISSN
  • 0013-726X (ISSN-L)
  • 1438-8812
OpenAlex
W4280496789
Cited by
66
References
9
FWCI
5.17
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.