Attempts at Perfect Normalization of Glucose Tolerance Test of Severe Diabetics by Artificial Beta Cell
The DOI matches its Crossref record.
Abstract
The artificial beta cell is a Glucose Controlled Insulin (and dextrose) Infusion System (GCIIS) for maintaining normoglycemia in diabetic conditions and other disturbances of metabolism. The insulin and dextrose infusion rates are calculated by a microcomputer according to the static glucose concentration (proportional control) and to its rate of change (dynamic control). The algorithms controlling the computer can be adapted to the subjects' requirements. It has already been shown, that the artificial beta cell is able to maintain blood sugar values in diabetics within physiological ranges during the course of the day. In our present study we examined the response of the artificial beta cell using a 100 gm oral glucose load in severe diabetics. The first type of control algorithms applied effected a rather small initial insulin infusion following OGTT in 8 juvenile diabetics connected with the artificial beta cell. The glucose responses thus obtained were similar to latent diabetes. In contrast, when the computer was controlled by the second type of algorithms with a more responsive dynamic control and a consequently higher initial insulin infusion, in one diabetic OGTT was fully normalized, whereas an improvement was achieved in another diabetic patient. Furthermore it was shown that control algorithms must be varied individually, depending on residual beta cell function and glucose regulatory mechanisms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bequette, B. W. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.28 · Cited by 270
The artificial pancreas: current status and future prospects in the management of diabetes
Peyser, T., Dassau, E., Breton, M., & Skyler, J. S. (2014) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.12431 · Cited by 169
Differential and integral corticosteroid feedback effects on acth secretion in hypoadrenocorticism
Fehm, H. L., Voigt, K. H., Kummer, G., Lang, R., & Pfeiffer, E. F. (1979) · Journal of Clinical Investigation · doi:10.1172/jci109296 · Cited by 51
Self-citationNosadini, R., Noy, G. A., Nattrass, M., Alberti, K. G. M. M., Johnston, D. G., Home, P. D., & �rskov, H. (1982) · Diabetologia · doi:10.1007/bf00252845 · Cited by 49
“Using the GCIIS, normoglycaemia has been achieved under a wide range of conditions [ 5-9 ].”
Background
Metadata
- Authors
- Kerner, W., Thum, C., Tamás jun., G., Beischer, W., Clemens, A., & Pfeiffer, E.
- Venue
- Hormone and Metabolic Research
- Publisher
- Georg Thieme Verlag KG
- Published
- 1976
- Volume
- 8
- Issue
- 04
- Pages
- 256-261
- ISSN
- 0018-5043 (ISSN-L)
- 1439-4286
- OpenAlex
- W2042147031
- Cited by
- 35
- References
- 0
- FWCI
- 3.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Attempts at Perfect Normalization of Glucose Tolerance Test of Severe Diabetics by Artificial Beta Cell. https://app.cochat.ai/papers/10.1055/s-0028-1093650
- The paper
- Kerner, W., Thum, C., Tamás jun., G., Beischer, W., Clemens, A., & Pfeiffer, E. (1976). Attempts at Perfect Normalization of Glucose Tolerance Test of Severe Diabetics by Artificial Beta Cell. Hormone and Metabolic Research. https://doi.org/10.1055/s-0028-1093650
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.