Pituitary function tests: Comparison of ACTH and 11-deoxy-cortisol responses in the metyrapone test and with the insulin hypoglycemia test
The DOI matches its Crossref record.
Abstract
PURPOSE: To compare the sensitivity of ACTH and 11-deoxy-cortisol (comp. S) responses in the short metyrapone test and the latter with the insulin hypoglycemia test. METHODS: Retrospective evaluation of 115 short metyrapone tests and comparison of 18 pairs of metyrapone and insulin tests. 20 healthy controls and 95 patients with confirmed pituitary disease were studied. All hormones were measured by sensitive radioimmunoassays. RESULTS: In patients with pituitary disease not requiring hydrocortisone substitution (n = 70), the ACTH response in the metyrapone test was subnormal in 47 cases (< 33 pmol/L), the comp. S response (< 200 nmol/L) in 21 cases only. Comparison of the relationship between ACTH and comp. S with an ACTH-cortisol dose-response curve obtained in normal subjects shows that subnormal ACTH responses after metyrapone in the range between 13 and 33 pmol/L still generate normal comp. S responses. The results of the metyrapone test correlated significantly with those of the insulin test. CONCLUSIONS: Measuring plasma ACTH in the scope of the metyrapone test makes the test more sensitive to detect secondary adrenal insufficiency than with steroid measurements alone. Results of the metyrapone test correlate significantly with the cortisol response to insulin hypoglycemia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Oelkers, W. (1996) · New England Journal of Medicine · doi:10.1056/nejm199610173351607 · Cited by 737
Hahner, S., Ross, R. J., Arlt, W., Bancos, I., Burger-Stritt, S., Torpy, D. J., Husebye, E. S., & Quinkler, M. (2021) · Nature Reviews Disease Primers · doi:10.1038/s41572-021-00252-7 · Cited by 223
Evaluation of the Integrity of the Hypothalamic-Pituitary-Adrenal Axis by Insulin Hypoglycemia Test1
Erturk, E., Jaffe, C. A., & Barkan, A. L. (1998) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.83.7.4980 · Cited by 204
Comparison of low and high dose corticotropin stimulation tests in patients with pituitary disease
Mayenknecht, J., Diederich, S., Bähr, V., Plöckinger, U., & Oelkers, W. (1998) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem.83.5.4831 · Cited by 142
Self-citationSelective use of the insulin tolerance test to diagnose hypopituitarism
Sarlos, S., & Inder, W. J. (2013) · Internal Medicine Journal · doi:10.1111/imj.12011 · Cited by 9
Metadata
- Authors
- Steiner, H., Bähr, V., Exner, P., & Oelkers, P.
- Venue
- Experimental and Clinical Endocrinology & Diabetes
- Publisher
- Georg Thieme Verlag KG
- Published
- 2009-07-15
- Volume
- 102
- Issue
- 01
- Pages
- 33-38
- ISSN
- 0947-7349 (ISSN-L)
- 1439-3646
- OpenAlex
- W1976930260
- Cited by
- 49
- References
- 0
- FWCI
- 1.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pituitary function tests: Comparison of ACTH and 11-deoxy-cortisol responses in the metyrapone test and with the insulin hypoglycemia test. https://app.cochat.ai/papers/10.1055/s-0029-1211262
- The paper
- Steiner, H., Bähr, V., Exner, P., & Oelkers, P. (2009). Pituitary function tests: Comparison of ACTH and 11-deoxy-cortisol responses in the metyrapone test and with the insulin hypoglycemia test. Experimental and Clinical Endocrinology & Diabetes. https://doi.org/10.1055/s-0029-1211262
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.