Small-bowel capsule endoscopy diagnoses early and advanced neoplasms in asymptomatic patients with Lynch syndrome
The DOI matches its Crossref record.
Abstract
BACKGROUND AND STUDY AIMS: Patients with Lynch syndrome are at increased risk of developing small-bowel adenocarcinoma, which usually has a bad prognosis and needs to be diagnosed early. Our aim was to evaluate the yield of capsule endoscopy and CT enteroclysis in this situation. PATIENTS AND METHODS: We performed a prospective, blinded, comparative study of capsule endoscopy and CT enteroclysis in five academic centers. Thirty-five consecutive asymptomatic patients with Lynch syndrome, all with one proven deleterious mutation, were included. A double reading was performed blind for both types of examination. RESULTS: Histologically confirmed small-bowel neoplasms were diagnosed in three patients (8.6 %): one adenocarcinoma (T3N0M0) and two adenomas with low-grade dysplasia. Capsule endoscopy identified all neoplasms. CT enteroclysis raised suspicion of one neoplasm (adenocarcinoma) but missed the two others. Concordance between the two capsule readings was high with a κ value of 0.78 (95 %CI 0.55 to 1.0), which was not the case for CT enteroclysis, where the κ value was 0.15 (95 %CI -0.27 to 0.58). CONCLUSION: Curable early or advanced neoplasms in asymptomatic patients with Lynch syndrome using capsule endoscopy can be detected with a better reproducibility than with CT enteroclysis. The clinical usefulness of systematic small-bowel screening in these patients should be confirmed through large prospective studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Syngal, S., Brand, R. E., Church, J. M., Giardiello, F. M., Hampel, H. L., & Burt, R. W. (2015) · American Journal of Gastroenterology · doi:10.1038/ajg.2014.435 · Cited by 1,662
Pennazio, M., Spada, C., Eliakim, R., Keuchel, M., May, A., Mulder, C., Rondonotti, E., Adler, S., Albert, J., Baltes, P., et al. (2015) · Endoscopy · doi:10.1055/s-0034-1391855 · Cited by 894
Self-citationVasen, H. F. A., Blanco, I., Aktan-Collan, K., Gopie, J. P., Alonso, A., Aretz, S., Bernstein, I., Bertario, L., Burn, J., Capella, G., et al. (2013) · Gut · doi:10.1136/gutjnl-2012-304356 · Cited by 746
Giardiello, F. M., Allen, J. I., Axilbund, J. E., Boland, C. R., Burke, C. A., Burt, R. W., Church, J. M., Dominitz, J. A., Johnson, D. A., Kaltenbach, T., et al. (2014) · Gastroenterology · doi:10.1053/j.gastro.2014.04.001 · Cited by 558
Monahan, K. J., Bradshaw, N., Dolwani, S., Desouza, B., Dunlop, M. G., East, J. E., Ilyas, M., Kaur, A., Lalloo, F., Latchford, A., et al. (2020) · Gut · doi:10.1136/gutjnl-2019-319915 · Cited by 484
Metadata
- Authors
- Saurin, J.-C., Pilleul, F., Soussan, E., Manière, T., D’Halluin, P., Gaudric, M., Cellier, C., Heresbach, D., & Gaudin, J.-L.
- Venue
- Endoscopy
- Publisher
- Georg Thieme Verlag KG
- Published
- 2010-09-06
- Volume
- 42
- Issue
- 12
- Pages
- 1057-1062
- ISSN
- 0013-726X (ISSN-L)
- 1438-8812
- OpenAlex
- W2313195711
- Cited by
- 74
- References
- 0
- FWCI
- 3.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Small-bowel capsule endoscopy diagnoses early and advanced neoplasms in asymptomatic patients with Lynch syndrome. https://app.cochat.ai/papers/10.1055/s-0030-1255742
- The paper
- Saurin, J.-C., Pilleul, F., Soussan, E., Manière, T., D’Halluin, P., Gaudric, M., Cellier, C., Heresbach, D., & Gaudin, J.-L. (2010). Small-bowel capsule endoscopy diagnoses early and advanced neoplasms in asymptomatic patients with Lynch syndrome. Endoscopy. https://doi.org/10.1055/s-0030-1255742
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.