CoChat

Effect of virtual endoscopy simulator training on performance of upper gastrointestinal endoscopy in patients: a randomized controlled trial

Ferlitsch, A., Schoefl, R., Puespoek, A., Miehsler, W., Schoeniger-Hekele, M., Hofer, H., Gangl, A., Homoncik, M. · 2010 · Endoscopy
Cited by 78

The DOI matches its Crossref record.

Abstract

BACKGROUND: Skills in gastrointestinal endoscopy mainly depend on experience and practice. Patients upon whom trainees perform their first endoscopic examinations are likely to suffer more discomfort and prolonged procedures. Training on endoscopy simulators may reduce the time required to reach competency in patient endoscopy. PATIENTS AND METHODS: Residents in internal medicine without experience of endoscopy were randomized to a group who trained on a simulator before conventional training (group S) or one that received conventional training only (group C) before starting upper gastrointestinal endoscopy in patients. After endoscopy, discomfort and pain were evaluated by patients, who were blind to the beginners' training status. Results in terms of time, technique (intubation, pyloric passage, J-maneuver), and diagnosis of pathological entities were evaluated by experts. RESULTS: From 2003 to 2007, 28 residents were enrolled. Comparing group S with group C in their first ten endoscopic examinations in patients, time taken to reach the duodenum (239 seconds (range 50 - 620) vs. 310 seconds (110 - 720; P < 0.0001) and technical accuracy ( P < 0.02) were significantly better in group S. Diagnostic accuracy did not differ between the groups. Fourteen residents (7 simulator-trained, 7 not simulator-trained) continued endoscopy training. After 60 endoscopic examinations, investigation time was still shorter in group S. Technical and diagnostic accuracy improved during on-patient training in both groups; here differences between groups were no longer observable. There were no significant differences in discomfort and pain scores between the groups after 10 and after 60 endoscopies. Discomfort and pain were higher than for endoscopy performed by experts. CONCLUSION: This randomized controlled trial shows that virtual simulator training significantly affects technical accuracy in the early and mid-term stages of endoscopic training. It helps reduce the time needed to reach technical competency, but clinically the effect is limited. Simulator training could be useful in an endoscopy training curriculum but cannot replace on-patient training.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-0030-1255818

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 78

Metadata

Authors
Ferlitsch, A., Schoefl, R., Puespoek, A., Miehsler, W., Schoeniger-Hekele, M., Hofer, H., Gangl, A., & Homoncik, M.
Venue
Endoscopy
Published
2010-10-22
Volume
42
Issue
12
Pages
1049-1056
ISSN
  • 0013-726X (ISSN-L)
  • 1438-8812
OpenAlex
W2154867989
Cited by
78
References
0
FWCI
4.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effect of virtual endoscopy simulator training on performance of upper gastrointestinal endoscopy in patients: a randomized controlled trial. https://app.cochat.ai/papers/10.1055/s-0030-1255818
The paper
Ferlitsch, A., Schoefl, R., Puespoek, A., Miehsler, W., Schoeniger-Hekele, M., Hofer, H., Gangl, A., & Homoncik, M. (2010). Effect of virtual endoscopy simulator training on performance of upper gastrointestinal endoscopy in patients: a randomized controlled trial. Endoscopy. https://doi.org/10.1055/s-0030-1255818

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.