The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
A Novel Algorithm for Autologous Ear Reconstruction
Open accessAbstract
Sculpting a tridimensional autologous rib cartilage framework is essential to restore a natural ear shape and becomes routine with preoperative training, but management of the skin is the key to minimizing complications. Here the authors provide a classification scheme to manage auricular skin: Type 1 is a Z-plasty with transposition of the lobule; type 2 is a transfixion incision of the microtic ear; type 3 exposes the cartilage remnants through a cutaneous incision. They also explain how to choose between the three types, depending upon the auricular skin potential. With training and method, results in ear reconstruction using autologous rib cartilage are excellent and reproducible.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brent, B. (1999) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199908000-00001 · Cited by 391
Nagata, S. (1994) · Plastic and Reconstructive Surgery · doi:10.1097/00006534-199402000-00001 · Cited by 361
Firmin, F. (1998) · Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery · doi:10.1080/02844319850158930 · Cited by 258
Self-citationMicrotia repair with rib cartilage grafts
Brent, B. (2002) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(01)00013-x · Cited by 230
State-of-the-Art Autogenous Ear Reconstruction in Cases of Microtia
Firmin, F. (2010) · Advances in Oto-Rhino-Laryngology · doi:10.1159/000314561 · Cited by 167
Self-citationThe Versatile Cartilage Autograft: Current Trends in Clinical Transplantation
Brent, B. (1979) · Clinics in Plastic Surgery · doi:10.1016/s0094-1298(20)32063-0 · Cited by 79
La reconstruction auriculaire en cas de microtie. Principes, méthodes et classification
Firmin, F. (2001) · Annales de Chirurgie Plastique Esthétique · doi:10.1016/s0294-1260(01)00056-5 · Cited by 66
Self-citationBrent, B. (1999) · Plastic & Reconstructive Surgery · doi:10.1097/00006534-199908000-00002 · Cited by 35
Firmin, F., Gratacap, B., & Manac'h, Y. (1998) · Scandinavian Journal of Plastic and Reconstructive Surgery and Hand Surgery · doi:10.1080/02844319850158949 · Cited by 25
Self-citation
Cited by
Duisit, J., Amiel, H., Wüthrich, T., Taddeo, A., Dedriche, A., Destoop, V., Pardoen, T., Bouzin, C., Joris, V., Magee, D., et al. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.04.009 · Cited by 99
Autologous ear reconstruction for microtia does not result in loss of cutaneous sensitivity.
Denadai, R., Raposo-Amaral, C. E., Zanco, G. L., & Raposo- Amaral, C. A. (2019) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000005485 · Cited by 12
Metadata
- Authors
- Firmin, F., & Marchac, A.
- Venue
- Seminars in Plastic Surgery
- Publisher
- Georg Thieme Verlag KG
- Published
- 2011-10-20
- Volume
- 25
- Issue
- 04
- Pages
- 257-264
- ISSN
- 1535-2188 (ISSN-L)
- 1536-0067
- OpenAlex
- W2017013021
- Cited by
- 266
- References
- 9
- FWCI
- 1.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Novel Algorithm for Autologous Ear Reconstruction. https://app.cochat.ai/papers/10.1055/s-0031-1288917
- The paper
- Firmin, F., & Marchac, A. (2011). A Novel Algorithm for Autologous Ear Reconstruction. Seminars in Plastic Surgery. https://doi.org/10.1055/s-0031-1288917
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.