Dynamic Needle Tip Positioning – Ultrasound Guidance for Peripheral Vascular Access. A Randomized, Controlled and Blinded Study in Phantoms Performed by Ultrasound Novices
The DOI matches its Crossref record.
Abstract
PURPOSE: The application of ultrasound-guidance for peripheral venous access is gaining popularity. It is possible to produce a short axis or a long axis sonographic view of the target vessel and apply an out-of-plane or in-plane needle tip approach. Our aim was to present the dynamic needle tip positioning technique and to estimate which approach is the most accurate for inserting the needle tip into the center of the target vessel. MATERIALS AND METHODS: Fiftynine novices in ultrasound-guided peripheral vascular access participated. (A) a short axis view combined with an out-of-plane needle tip approach using dynamic needle tip positioning was compared to (B) a long axis view combined with an in-plane needle tip approach to a target vessel embedded in a gelatine phantom. RESULTS: The success rate of method (A) was significantly higher than method (B) (97 % versus 81 %). The distance between the center of the target vessel and the final needle tip position was significantly shorter for method (A) compared to method (B). CONCLUSION: The combined short axis and out-of-plane technique using dynamic needle tip positioning had a higher success rate and a shorter distance between the center of the target vessel and the needle tip compared to the combined long axis and in-plane technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bhattacharjee, S., Maitra, S., & Baidya, D. K. (2018) · Journal of Clinical Anesthesia · doi:10.1016/j.jclinane.2018.03.019 · Cited by 91
Kim, S. Y., Kim, K. N., Jeong, M. A., Lee, B. S., & Lim, H. J. (2021) · PLOS ONE · doi:10.1371/journal.pone.0251712 · Cited by 26
“To compensate for this drawback of the SAX-OOP approach, the dynamic needle tip positioning (DNTP) technique was introduced [9].”
MethodAnderssen, L. M., Petersen, M. S., Wang, A. G., Mohr, M., & Fjallheim, A. S. (2026) · The Journal of Vascular Access · doi:10.1177/11297298251347816 · Cited by 11
“10,15 Dynamic Needle Tip Positioning (DNTP) is a dynamic short-axis approach 15,16 which has proven to have a markedly higher success rate (97”
Metadata
- Authors
- Clemmesen, L., Knudsen, L., Sloth, E., & Bendtsen, T.
- Venue
- Ultraschall in der Medizin - European Journal of Ultrasound
- Publisher
- Georg Thieme Verlag KG
- Published
- 2012-10-11
- Volume
- 33
- Issue
- 07
- Pages
- E321-E325
- ISSN
- 0172-4614 (ISSN-L)
- 1438-8782
- OpenAlex
- W2031405870
- Cited by
- 93
- References
- 0
- FWCI
- 3.15
- Type
- journal article
- Language
- de
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Dynamic Needle Tip Positioning – Ultrasound Guidance for Peripheral Vascular Access. A Randomized, Controlled and Blinded Study in Phantoms Performed by Ultrasound Novices. https://app.cochat.ai/papers/10.1055/s-0032-1312824
- The paper
- Clemmesen, L., Knudsen, L., Sloth, E., & Bendtsen, T. (2012). Dynamic Needle Tip Positioning – Ultrasound Guidance for Peripheral Vascular Access. A Randomized, Controlled and Blinded Study in Phantoms Performed by Ultrasound Novices. Ultraschall in der Medizin - European Journal of Ultrasound. https://doi.org/10.1055/s-0032-1312824
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.