CoChat

Ultrasound-guided dynamic needle tip positioning technique for radial artery cannulation in elderly patients: A prospective randomized controlled study

Open access

The DOI matches its Crossref record; 33 of the 34 references it cites were found in a registry or an index.

Abstract

Background: Radial artery cannulation, which is a useful procedure for anesthetic management, is often challenging in elderly patients. Recently, the dynamic needle tip positioning (DNTP) technique was introduced to facilitate ultrasound-guided vascular catheterization. Therefore, we performed this prospective, parallel group, randomized, controlled trial to compare the ultrasound-guided DNTP technique with the palpation method in elderly patients. Methods: For this study, 256 patients aged 65 years or older were randomly allocated to the ultrasound-guided DNTP technique group (DNTP group) or the palpation method group (palpation group). The primary outcome was first-attempt success rate. The secondary outcomes were overall success rate, numbers of attempts and redirections, cannulation time, and incidence of complications. Results: The first-attempt success rate (85.9% vs. 72.3%; relative risk [RR], 1.47; 95% CI 1.25–1.72; P<0.001) and the overall success rate (99.2% vs. 93.0%; RR, 1.07; 95% CI 1.02–1.12; P = 0.01) were significantly higher in the DNTP group compared to the palpation group. The numbers of attempts [1 (1,1) vs. 1 (1,3), P<0.001] and redirections [0 (0,1) vs. 2 (0,4), P<0.001] were significantly lower in the DNTP group. The cannulation time for successful attempts was 42 (32,55) seconds in the DNTP group and 53 (36,78) seconds in the palpation group (P<0.001). The incidence of hematoma was significantly lower in the DNTP group (7% vs. 24.2%; RR, 0.29; 95% CI, 0.14–0.59; P<0.001). Conclusions: Ultrasound-guided radial artery cannulation with the DNTP technique improved the efficiency of radial artery cannulation in elderly patients by increasing the success rate while minimizing complications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1371/journal.pone.0251712

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Figures

Fig 1 Flow diagram of patient recruitment and exclusion criteria for the study. DNTP, dynamic needle tip positioning technique.
Fig 1 Flow diagram of patient recruitment and exclusion criteria for the study. DNTP, dynamic needle tip positioning technique.CC BY · PubMed Central
Fig 2 Ultrasound-guided DNTP technique. The radial artery (RA) was identified in an out-of-plane approach with an ultrasound probe. (A) The needle was inserted through the skin, and the needle tip (arrowhead) appeared as a hyperechoic dot on the display. (B) The probe was moved slightly further without moving the needle, and the hyperechoic dot disappeared as the needle tip exited the ultrasound plane. (C) The needle was advanced toward the radial artery with the probe held in place, and the needle punctured the radial artery. (D) The probe was moved proximally again, and the needle tip disappeared from the display. (E) The needle was advanced, and it was confirmed that the needle tip remained in the radial artery. Arrowheads on the ultrasound images indicate the needle tip of the angiocatheter. DNTP, dynamic needle tip positioning.
Fig 2 Ultrasound-guided DNTP technique. The radial artery (RA) was identified in an out-of-plane approach with an ultrasound probe. (A) The needle was inserted through the skin, and the needle tip (arrowhead) appeared as a hyperechoic dot on the display. (B) The probe was moved slightly further without moving the needle, and the hyperechoic dot disappeared as the needle tip exited the ultrasound plane. (C) The needle was advanced toward the radial artery with the probe held in place, and the needle punctured the radial artery. (D) The probe was moved proximally again, and the needle tip disappeared from the display. (E) The needle was advanced, and it was confirmed that the needle tip remained in the radial artery. Arrowheads on the ultrasound images indicate the needle tip of the angiocatheter. DNTP, dynamic needle tip positioning.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Research works printed but not linked: 1

  1. The Royal College of Radiologists, 2012, Focused ultrasound training standards

Cited by

See all 26

Metadata

Authors
Kim, S. Y., Kim, K. N., Jeong, M. A., Lee, B. S., & Lim, H. J.
Affiliations
Hanyang University Seoul Hospital (KR)
Corresponding author
Kim, Kyu Nam
Venue
PLOS ONE
Published
2021-05-14
Volume
16
Issue
5
Pages
e0251712
ISSN
1932-6203 (ISSN-L)
OpenAlex
W3163527229
Cited by
26
References
34
Citations by year
2026: 3 · 2025: 3 · 2024: 6 · 2023: 6 · 2022: 5 · 2021: 2
FWCI
3.08
Type
journal article
Language
en
Open access
Locations
  • PLoS ONE (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Vascular Procedures and Complications
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
Keywords
radial artery cannulation, ultrasound-guided vascular access, elderly patients, first-attempt success rate, cannulation time, hematoma, vascular access complications
MeSH terms
Aged, Aged, 80 and over, Catheterization, Peripheral, Female, Humans, Male, Needles, Prospective Studies, Radial Artery, Ultrasonography, Interventional

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultrasound-guided dynamic needle tip positioning technique for radial artery cannulation in elderly patients: A prospective randomized controlled study. https://app.cochat.ai/papers/10.1371/journal.pone.0251712
The paper
Kim, S. Y., Kim, K. N., Jeong, M. A., Lee, B. S., & Lim, H. J. (2021). Ultrasound-guided dynamic needle tip positioning technique for radial artery cannulation in elderly patients: A prospective randomized controlled study. PLOS ONE. https://doi.org/10.1371/journal.pone.0251712

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.