Ultrasound-guided dynamic needle tip positioning technique for radial artery cannulation in elderly patients: A prospective randomized controlled study
Open accessThe DOI matches its Crossref record; 33 of the 34 references it cites were found in a registry or an index.
Abstract
Background: Radial artery cannulation, which is a useful procedure for anesthetic management, is often challenging in elderly patients. Recently, the dynamic needle tip positioning (DNTP) technique was introduced to facilitate ultrasound-guided vascular catheterization. Therefore, we performed this prospective, parallel group, randomized, controlled trial to compare the ultrasound-guided DNTP technique with the palpation method in elderly patients. Methods: For this study, 256 patients aged 65 years or older were randomly allocated to the ultrasound-guided DNTP technique group (DNTP group) or the palpation method group (palpation group). The primary outcome was first-attempt success rate. The secondary outcomes were overall success rate, numbers of attempts and redirections, cannulation time, and incidence of complications. Results: The first-attempt success rate (85.9% vs. 72.3%; relative risk [RR], 1.47; 95% CI 1.25–1.72; P<0.001) and the overall success rate (99.2% vs. 93.0%; RR, 1.07; 95% CI 1.02–1.12; P = 0.01) were significantly higher in the DNTP group compared to the palpation group. The numbers of attempts [1 (1,1) vs. 1 (1,3), P<0.001] and redirections [0 (0,1) vs. 2 (0,4), P<0.001] were significantly lower in the DNTP group. The cannulation time for successful attempts was 42 (32,55) seconds in the DNTP group and 53 (36,78) seconds in the palpation group (P<0.001). The incidence of hematoma was significantly lower in the DNTP group (7% vs. 24.2%; RR, 0.29; 95% CI, 0.14–0.59; P<0.001). Conclusions: Ultrasound-guided radial artery cannulation with the DNTP technique improved the efficiency of radial artery cannulation in elderly patients by increasing the success rate while minimizing complications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures


Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Furthermore, US guidance improves outcomes for peripheral IV (PIV) placement and radial arterial cannulation – including in pediatric patients – compared to landmark techniques [ 2 – 5 ].”
From Ultrasound vessel sizing before cannulation: a measurement-first approach for anesthesiologists (2026) · cites this paper as [4]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Furthermore, US guidance improves outcomes for peripheral IV (PIV) placement and radial arterial cannulation – including in pediatric patients – compared to landmark techniques [ 2 – 5 ].”
From Ultrasound vessel sizing before cannulation: a measurement-first approach for anesthesiologists (2026) · cites this paper as [4]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The evidence compiled in this review indicates higher first-pass success rates, fewer attempts, faster placement times, and reduced complication rates when ultrasound pre-measurement and real-time guidance are used compared to traditional landmark techniques [ 2 – 5 , 13 ].”
From Ultrasound vessel sizing before cannulation: a measurement-first approach for anesthesiologists (2026) · cites this paper as [4]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guralnik, J. M., Eisenstaedt, R. S., Ferrucci, L., Klein, H. G., & Woodman, R. C. (2004) · Blood · doi:10.1182/blood-2004-05-1812 · Cited by 1,450
Scheer, B., Perel, A., & Pfeiffer, U. J. (2002) · Critical Care · doi:10.1186/cc1489 · Cited by 854 · cited 2×
“Hematoma at the puncture site can interfere with subsequent attempts and is associated with an increased incidence of occlusion [1, 2].”
BackgroundKonrad, C., Schupfer, G., Wietlisbach, M., & Gerber, H. (1998) · Anesthesia & Analgesia · doi:10.1213/00000539-199803000-00037 · Cited by 545 · cited 1×
“The number of prerequisite cases for each procedure was based on previous literature, which identified learning curves for radial artery cannulation [19, 20] and ultrasound needle visualization [21], as well as recommendations for ultrasound training [22].”
MethodTwisted Blood Vessels: Symptoms, Etiology and Biomechanical Mechanisms
Han, H.-C. (2012) · Journal of Vascular Research · doi:10.1159/000335123 · Cited by 489
Troianos, C. A., Hartman, G. S., Glas, K. E., Skubas, N. J., Eberhardt, R. T., Walker, J. D., & Reeves, S. T. (2011) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2011.09.021 · Cited by 420 · cited 1×
“Although the SAX-OOP approach offers a better view of surrounding structures during a targeted vessel approach, the posterior wall puncture rate is significantly higher [7, 8].”
BackgroundKrumholz, H. M., Chen, Y.-T., Vaccarino, V., Wang, Y., Radford, M. J., Bradford, W. D., & Horwitz, R. I. (2000) · The American Journal of Cardiology · doi:10.1016/s0002-9149(00)00705-0 · Cited by 379
Radial Artery Cannulation: A Comprehensive Review of Recent Anatomic and Physiologic Investigations
Brzezinski, M., Luisetti, T., & London, M. J. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e3181bbd416 · Cited by 354 · cited 2×
“Hematoma at the puncture site can interfere with subsequent attempts and is associated with an increased incidence of occlusion [1, 2].”
BackgroundAge-related Impairment of Vascular Structure and Functions
Xu, X., Wang, B., Ren, C., Hu, J., Greenberg, D. A., Chen, T., Xie, L., & Jin, K. (2017) · Aging and disease · doi:10.14336/ad.2017.0430 · Cited by 330
Real-Time Ultrasound Guidance Facilitates Transradial Access
Seto, A. H., Roberts, J. S., Abu-Fadel, M. S., Czak, S. J., Latif, F., Jain, S. P., Raza, J. A., Mangla, A., Panagopoulos, G., Patel, P. M., et al. (2015) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2014.05.036 · Cited by 236 · cited 1×
“Spasm was identified by the operator as any significant resistance [23].”
BackgroundArterial structure and function in vascular ageing: are you as old as your arteries?
Thijssen, D. H. J., Carter, S. E., & Green, D. J. (2016) · The Journal of Physiology · doi:10.1113/jp270597 · Cited by 220
Research works printed but not linked: 1
- The Royal College of Radiologists, 2012, Focused ultrasound training standards
Cited by
Ultrasound guidance for arterial (other than femoral) catheterisation in adults
Flumignan, R. L., Trevisani, V. F. M., Lópes, R. D., Baptista-Silva, J. C., Flumignan, C. D. Q., & Nakano, L. C. U. (2021) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013585.pub2 · Cited by 37
Ultrasound guidance for arterial (other than femoral) catheterisation in adults
Flumignan, R. L., Trevisani, V. F. M., Lópes, R. D., Baptista-Silva, J. C., Flumignan, C. D. Q., & Nakano, L. C. U. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd013585 · Cited by 26
Shim, J., Cho, E.-A., Gahng, T.-R., Park, J., Lee, E. K., Oh, E. J., & Ahn, J. H. (2022) · PLoS ONE · doi:10.1371/journal.pone.0273563 · Cited by 13
Wu, G., Chen, C., Gu, X., Yao, Y., Yuan, D., Lv, J., Zhao, B., & Wang, Q. (2022) · Journal of Clinical Medicine · doi:10.3390/jcm11216539 · Cited by 12
“P Adult 260 [13] Soo Yeon Kim 2021 Korea 22G Radial artery DNTP vs.”
Sung, J. M., Jun, Y. E., Jung, Y. D., & Kim, K. N. (2023) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2023.08.138 · Cited by 10
Self-citation
Metadata
- Authors
- Kim, S. Y., Kim, K. N., Jeong, M. A., Lee, B. S., & Lim, H. J.
- Affiliations
- Hanyang University Seoul Hospital (KR)
- Corresponding author
- Kim, Kyu Nam
- Venue
- PLOS ONE
- Publisher
- Public Library of Science (PLoS)
- Published
- 2021-05-14
- Volume
- 16
- Issue
- 5
- Pages
- e0251712
- ISSN
- 1932-6203 (ISSN-L)
- PMC
- PMC8121362
- OpenAlex
- W3163527229
- Semantic Scholar
- fb283a748b4e7bf5adc1d1761357ead3f3be3cec
- Cited by
- 26
- References
- 34
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 6 · 2023: 6 · 2022: 5 · 2021: 2
- FWCI
- 3.08
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- PLoS ONE (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Vascular Procedures and Complications
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Health and Disease Prevention
- Keywords
- radial artery cannulation, ultrasound-guided vascular access, elderly patients, first-attempt success rate, cannulation time, hematoma, vascular access complications
- MeSH terms
- Aged, Aged, 80 and over, Catheterization, Peripheral, Female, Humans, Male, Needles, Prospective Studies, Radial Artery, Ultrasonography, Interventional
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Ultrasound-guided dynamic needle tip positioning technique for radial artery cannulation in elderly patients: A prospective randomized controlled study. https://app.cochat.ai/papers/10.1371/journal.pone.0251712
- The paper
- Kim, S. Y., Kim, K. N., Jeong, M. A., Lee, B. S., & Lim, H. J. (2021). Ultrasound-guided dynamic needle tip positioning technique for radial artery cannulation in elderly patients: A prospective randomized controlled study. PLOS ONE. https://doi.org/10.1371/journal.pone.0251712
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.