Multicenter, randomized, tandem evaluation of EndoRings colonoscopy – results of the CLEVER study
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND STUDY AIMS: Adenoma miss rate during colonoscopy has become a widely acknowledged proxy measure for post-colonoscopy colorectal cancer. Among other reasons, this can happen because of inadequate visualization of the proximal aspects of colonic folds and flexures. EndoRings (EndoAid Ltd., Caesarea, Israel) is a silicone-rubber device that is fitted onto the distal end of the colonoscope. Its flexible circular rings engage and mechanically stretch colonic folds during withdrawal. The primary aim of this study was to compare adenoma miss rates between standard colonoscopy and colonoscopy using EndoRings. METHODS: In this multicenter, randomized, tandem colonoscopy study, we performed same-day, back-to-back colonoscopies with EndoRings followed by standard colonoscopy, or vice versa. RESULTS: After exclusion of 10 patients for protocol violations, 116 patients (38.8% female; mean age 58.7) remained for analysis. The adenoma miss rate of EndoRings colonoscopy (7/67; 10.4%) was significantly lower (P<0.001) compared with standard colonoscopy (28/58; 48.3%). Similar results were found for polyp miss rates: EndoRings (9.1%) and standard colonoscopy (52.8%; P<0.001). Mean cecal intubation times (9.3 vs. 8.4 minutes; P=0.142) and withdrawal times (7.4 vs. 7.2 minutes; P=0.286), respectively, were not significantly different between EndoRings and standard colonoscopy. Mean total procedure time was longer with EndoRings than with standard colonoscopy (21.6 vs. 18.5 minutes, P=0.001) as more polyps were removed. CONCLUSIONS: This study demonstrates that colonoscopy with EndoRings has lower adenoma and polyp miss rates than standard colonoscopy, which may improve the efficacy particularly of screening and surveillance colonoscopies. ClinicalTrials.gov NCT01955122.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quality indicators for colonoscopy
Rex, D. K., Schoenfeld, P. S., Cohen, J., Pike, I. M., Adler, D. G., Fennerty, M. B., Lieb, J. G., Park, W. G., Rizk, M. K., Sawhney, M. S., et al. (2015) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2014.07.058 · Cited by 1,764
Self-citation
Cited by
ACG Clinical Guidelines: Colorectal Cancer Screening 2021
Shaukat, A., Kahi, C. J., Burke, C. A., Rabeneck, L., Sauer, B. G., & Rex, D. K. (2021) · American Journal of Gastroenterology · doi:10.14309/ajg.0000000000001122 · Cited by 853
Self-citationZhao, S., Wang, S., Pan, P., Xia, T., Chang, X., Yang, X., Guo, L., Meng, Q., Yang, F., Qian, W., et al. (2019) · Gastroenterology · doi:10.1053/j.gastro.2019.01.260 · Cited by 660
Møller, P., Seppälä, T., Bernstein, I., Holinski-Feder, E., Sala, P., Evans, D. G., Lindblom, A., Macrae, F., Blanco, I., Sijmons, R., et al. (2017) · Gut · doi:10.1136/gutjnl-2015-309675 · Cited by 548
Endoscopic Improvement of the Adenoma Detection Rate during Colonoscopy - Where Do We Stand in 2015?
Floer, M., & Meister, T. (2016) · Digestion · doi:10.1159/000442464 · Cited by 300
Kamba, S., Tamai, N., Saitoh, I., Matsui, H., Horiuchi, H., Kobayashi, M., Sakamoto, T., Ego, M., Fukuda, A., Tonouchi, A., et al. (2021) · Journal of Gastroenterology · doi:10.1007/s00535-021-01808-w · Cited by 124
Metadata
- Authors
- Dik, V., Gralnek, I., Segol, O., Suissa, A., Belderbos, T., Moons, L., Segev, M., Domanov, S., Rex, D., & Siersema, P.
- Venue
- Endoscopy
- Publisher
- Georg Thieme Verlag KG
- Published
- 2015-07-28
- Volume
- 47
- Issue
- 12
- Pages
- 1151-1158
- ISSN
- 0013-726X (ISSN-L)
- 1438-8812
- OpenAlex
- W955507656
- Cited by
- 116
- References
- 1
- FWCI
- 7.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multicenter, randomized, tandem evaluation of EndoRings colonoscopy – results of the CLEVER study. https://app.cochat.ai/papers/10.1055/s-0034-1392421
- The paper
- Dik, V., Gralnek, I., Segol, O., Suissa, A., Belderbos, T., Moons, L., Segev, M., Domanov, S., Rex, D., & Siersema, P. (2015). Multicenter, randomized, tandem evaluation of EndoRings colonoscopy – results of the CLEVER study. Endoscopy. https://doi.org/10.1055/s-0034-1392421
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.