CoChat

Confocal laser endomicroscopy: a novel method for prediction of relapse in Crohn’s disease

Karstensen, John, Săftoiu, Adrian, Brynskov, Jørn, Hendel, Jakob, Klausen, Pia, Cârtână, Tatiana, Klausen, Tobias, Riis, Lene, Vilmann, Peter · 2015 · Endoscopy
Cited by 35

The DOI matches its Crossref record.

Abstract

BACKGROUND AND STUDY AIMS: Confocal laser endomicroscopy (CLE) has been shown to predict relapse in ulcerative colitis in remission, but little is currently known about its role in Crohn's disease. The aim of this study was to identify reproducible CLE features in patients with Crohn's disease and to examine whether these are risk factors for relapse. PATIENTS AND METHODS: This was a single-center prospective feasibility study of CLE imaging in patients with Crohn's disease. CLE imaging was performed in the terminal ileum and four colorectal sites, and was correlated with histopathology and macroscopic appearance. Clinical relapse, defined as the need for treatment escalation or surgical intervention, was recorded during follow-up. RESULTS: The study included 50 patients: 39 with Crohn's disease (20 in remission), and 11 controls. Ileal fluorescein leakage and microerosions were significantly more frequent in patients with endoscopically active Crohn's disease compared with patients with inactive Crohn's disease and controls (P = 0.005 and (P = 0.006, respectively). The same applied to colorectal fluorescein leakage and vascular alterations ((P = 0.043 and (P = 0.034, respectively). During a 12-month follow-up period, ileal fluorescein leakage and microerosions were significant risk factors for relapse in the subgroup of patients in remission (log rank (P = 0.009 and (P = 0.007, respectively) as well as in the entire group of patients with Crohn's disease (log rank (P = 0.006 and (P = 0.01, respectively). Inter- and intraobserver reproducibility was almost perfect (κ > 0.80) or substantial (κ > 0.60) for the majority of CLE parameters. CONCLUSIONS: CLE can identify reproducible microscopic changes in the terminal ileum that are risk factors for relapse in patients with otherwise inactive Crohn's disease. TRIAL REGISTRATION: ClinicalTrials.gov (NCT01738529).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-0034-1393314

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 35

Metadata

Authors
Karstensen, J., Săftoiu, A., Brynskov, J., Hendel, J., Klausen, P., Cârtână, T., Klausen, T., Riis, L., & Vilmann, P.
Venue
Endoscopy
Published
2015-11-19
Volume
48
Issue
04
Pages
364-372
ISSN
  • 0013-726X (ISSN-L)
  • 1438-8812
OpenAlex
W2031100179
Cited by
35
References
0
FWCI
2.67
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Confocal laser endomicroscopy: a novel method for prediction of relapse in Crohn’s disease. https://app.cochat.ai/papers/10.1055/s-0034-1393314
The paper
Karstensen, J., Săftoiu, A., Brynskov, J., Hendel, J., Klausen, P., Cârtână, T., Klausen, T., Riis, L., & Vilmann, P. (2015). Confocal laser endomicroscopy: a novel method for prediction of relapse in Crohn’s disease. Endoscopy. https://doi.org/10.1055/s-0034-1393314

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.