A meta-analysis comparing ProCore and standard fine-needle aspiration needles for endoscopic ultrasound-guided tissue acquisition
The DOI matches its Crossref record.
Abstract
BACKGROUND AND STUDY AIMS: To overcome the limitations associated with cytology, a uniquely designed needle (ProCore) was introduced in an effort to obtain a core of tissue under endoscopic ultrasound (EUS) guidance. However, studies comparing the sample quality between ProCore and standard-design fine-needle aspiration (FNA) needles have yielded varying results. A systematic review and meta-analysis was therefore conducted to compare the performance of the ProCore and standard FNA needles when performing EUS-guided tissue acquisition. PATIENTS AND METHODS: MEDLINE and EMBASE were searched to identify all published manuscripts that compared the ProCore needle with standard FNA needles. Noncomparative and technical feasibility studies were excluded. The main outcome measures were diagnostic adequacy, diagnostic accuracy, acquisition of histological core tissue, and mean number of passes required to achieve a diagnosis when sampling solid lesions. RESULTS: Nine studies (total 576 patients) met the inclusion criteria. There was no significant difference in diagnostic adequacy (75.2 % vs. 89.0 %, odds ratio [OR] 0.39, P = 0.23), diagnostic accuracy (85.8 % vs. 86.2 %, OR 0.88, P = 0.53) or rate of histological core specimen acquisition (77.7 % vs. 76.5 %, OR 0.94, P = 0.85) between the ProCore and standard FNA needles, respectively. The mean number of passes required for diagnosis, however, was significantly lower when using the ProCore needle (standardized mean difference - 1.2, P < 0.001). CONCLUSIONS: Current data do not demonstrate a significant difference between the ProCore and standard FNA needles for sample adequacy, diagnostic accuracy or acquisition of a core specimen. However, the ProCore needle establishes the diagnosis with fewer passes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Challenges in diagnosis of pancreatic cancer
Zhang, L., Sanagapalli, S., & Stoita, A. (2018) · World Journal of Gastroenterology · doi:10.3748/wjg.v24.i19.2047 · Cited by 588
Polkowski, M., Jenssen, C., Kaye, P., Carrara, S., Deprez, P., Gines, A., Fernández-Esparrach, G., Eisendrath, P., Aithal, G., Arcidiacono, P., et al. (2017) · Endoscopy · doi:10.1055/s-0043-119219 · Cited by 370
European Guideline on IgG4-related digestive disease - UEG and SGF evidence-based recommendations
Löhr, J., Beuers, U., Vujasinovic, M., Alvaro, D., Frøkjær, J. B., Buttgereit, F., Capurso, G., Culver, E. L., de‐Madaria, E., Della‐Torre, E., et al. (2020) · United European Gastroenterology Journal · doi:10.1177/2050640620934911 · Cited by 252
Tiriac, H., Bucobo, J. C., Tzimas, D., Grewel, S., Lacomb, J. F., Rowehl, L. M., Nagula, S., Wu, M., Kim, J., Sasson, A., et al. (2018) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2017.12.032 · Cited by 164
Metadata
- Authors
- Bang, J., Hawes, R., & Varadarajulu, S.
- Venue
- Endoscopy
- Publisher
- Georg Thieme Verlag KG
- Published
- 2015-11-12
- Volume
- 48
- Issue
- 04
- Pages
- 339-349
- ISSN
- 0013-726X (ISSN-L)
- 1438-8812
- OpenAlex
- W2292252589
- Cited by
- 233
- References
- 0
- FWCI
- 16.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A meta-analysis comparing ProCore and standard fine-needle aspiration needles for endoscopic ultrasound-guided tissue acquisition. https://app.cochat.ai/papers/10.1055/s-0034-1393354
- The paper
- Bang, J., Hawes, R., & Varadarajulu, S. (2015). A meta-analysis comparing ProCore and standard fine-needle aspiration needles for endoscopic ultrasound-guided tissue acquisition. Endoscopy. https://doi.org/10.1055/s-0034-1393354
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.