CoChat

A meta-analysis comparing ProCore and standard fine-needle aspiration needles for endoscopic ultrasound-guided tissue acquisition

Bang, Ji, Hawes, Robert, Varadarajulu, Shyam · 2015 · Endoscopy
Cited by 233

The DOI matches its Crossref record.

Abstract

BACKGROUND AND STUDY AIMS: To overcome the limitations associated with cytology, a uniquely designed needle (ProCore) was introduced in an effort to obtain a core of tissue under endoscopic ultrasound (EUS) guidance. However, studies comparing the sample quality between ProCore and standard-design fine-needle aspiration (FNA) needles have yielded varying results. A systematic review and meta-analysis was therefore conducted to compare the performance of the ProCore and standard FNA needles when performing EUS-guided tissue acquisition. PATIENTS AND METHODS: MEDLINE and EMBASE were searched to identify all published manuscripts that compared the ProCore needle with standard FNA needles. Noncomparative and technical feasibility studies were excluded. The main outcome measures were diagnostic adequacy, diagnostic accuracy, acquisition of histological core tissue, and mean number of passes required to achieve a diagnosis when sampling solid lesions. RESULTS: Nine studies (total 576 patients) met the inclusion criteria. There was no significant difference in diagnostic adequacy (75.2 % vs. 89.0 %, odds ratio [OR] 0.39, P = 0.23), diagnostic accuracy (85.8 % vs. 86.2 %, OR 0.88, P = 0.53) or rate of histological core specimen acquisition (77.7 % vs. 76.5 %, OR 0.94, P = 0.85) between the ProCore and standard FNA needles, respectively. The mean number of passes required for diagnosis, however, was significantly lower when using the ProCore needle (standardized mean difference - 1.2, P < 0.001). CONCLUSIONS: Current data do not demonstrate a significant difference between the ProCore and standard FNA needles for sample adequacy, diagnostic accuracy or acquisition of a core specimen. However, the ProCore needle establishes the diagnosis with fewer passes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-0034-1393354

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 233

Metadata

Authors
Bang, J., Hawes, R., & Varadarajulu, S.
Venue
Endoscopy
Published
2015-11-12
Volume
48
Issue
04
Pages
339-349
ISSN
  • 0013-726X (ISSN-L)
  • 1438-8812
OpenAlex
W2292252589
Cited by
233
References
0
FWCI
16.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A meta-analysis comparing ProCore and standard fine-needle aspiration needles for endoscopic ultrasound-guided tissue acquisition. https://app.cochat.ai/papers/10.1055/s-0034-1393354
The paper
Bang, J., Hawes, R., & Varadarajulu, S. (2015). A meta-analysis comparing ProCore and standard fine-needle aspiration needles for endoscopic ultrasound-guided tissue acquisition. Endoscopy. https://doi.org/10.1055/s-0034-1393354

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.