Evidence-Based Evaluation of Inferior Vena Cava Filter Complications Based on Filter Type
Open accessThe DOI matches its Crossref record; 90 of the 90 references it cites were found in a registry or an index.
Abstract
Many inferior vena cava (IVC) filter types, along with their specific risks and complications, are not recognized. The purpose of this study was to evaluate the various FDA-approved IVC filter types to determine device-specific risks, as a way to help identify patients who may benefit from ongoing follow-up versus prompt filter retrieval. An evidence-based electronic search (FDA Premarket Notification, MEDLINE, FDA MAUDE) was performed to identify all IVC filter types and device-specific complications from 1980 to 2014. Twenty-three IVC filter types (14 retrievable, 9 permanent) were identified. The devices were categorized as follows: conical (n = 14), conical with umbrella (n = 1), conical with cylindrical element (n = 2), biconical with cylindrical element (n = 2), helical (n = 1), spiral (n = 1), and complex (n = 1). Purely conical filters were associated with the highest reported risks of penetration (90-100%). Filters with cylindrical or umbrella elements were associated with the highest reported risk of IVC thrombosis (30-50%). Conical Bard filters were associated with the highest reported risks of fracture (40%). The various FDA-approved IVC filter types were evaluated for device-specific complications based on best current evidence. This information can be used to guide and optimize clinical management in patients with indwelling IVC filters.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Systematic Review of the Use of Retrievable Inferior Vena Cava Filters
Angel, L. F., Tapson, V., Galgon, R. E., Restrepo, M. I., & Kaufman, J. (2011) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2011.08.024 · Cited by 474
Twenty-one-Year Trends in the Use of Inferior Vena Cava Filters
Stein, P. D., Kayali, F., & Olson, R. E. (2004) · Archives of Internal Medicine · doi:10.1001/archinte.164.14.1541 · Cited by 329
Percutaneous inferior vena caval filters: follow-up of seven designs in 320 patients.
Ferris, E. J., McCowan, T. C., Carver, D. K., & McFarland, D. R. (1993) · Radiology · doi:10.1148/radiology.188.3.8351361 · Cited by 301
Caplin, D. M., Nikolic, B., Kalva, S. P., Ganguli, S., Saad, W. E. A., & Zuckerman, D. A. (2011) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2011.07.012 · Cited by 278
Twelve-year clinical experience with the Greenfield vena caval filter.
Greenfield, L. J., & Michna, B. A. (1988) · PubMed · Cited by 262
Nicholson, W., Nicholson, W. J., Tolerico, P., Taylor, B., Solomon, S., Schryver, T., McCullum, K., Goldberg, H., Mills, J., Schuler, B., et al. (2010) · Archives of Internal Medicine · doi:10.1001/archinternmed.2010.316 · Cited by 223
Twenty-year clinical experience with the Greenfield filter
Greenfield, L. (1995) · Cardiovascular Surgery · doi:10.1016/0967-2109(95)90895-c · Cited by 188
Durack, J. C., Westphalen, A. C., Kekulawela, S., Bhanu, S. B., Avrin, D. E., Gordon, R. L., & Kerlan, R. K. (2012) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-011-0151-9 · Cited by 177
Decision analysis of retrievable inferior vena cava filters in patients without pulmonary embolism
Morales, J. P., Li, X., Irony, T., Ibrahim, N. G., Moynahan, M., & Cavanaugh, K. J. (2013) · Journal of Vascular Surgery Venous and Lymphatic Disorders · doi:10.1016/j.jvsv.2013.04.005 · Cited by 153
Mismetti, P., Rivron-Guillot, K., Quenet, S., Decousus, H., Laporte, S., Epinat, M., & Barral, F. G. (2007) · CHEST Journal · doi:10.1378/chest.06-0631 · Cited by 153
Cited by
Ortel, T. L., Neumann, I., Ageno, W., Beyth, R., Clark, N. P., Cuker, A., Hutten, B. A., Jaff, M. R., Manja, V., Schulman, S., et al. (2020) · Blood Advances · doi:10.1182/bloodadvances.2020001830 · Cited by 1,489
Duffett, L. D., & Carrier, M. (2016) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.13564 · Cited by 128
Marron, R. M., Rali, P. M., Hountras, P., & Bull, T. M. (2020) · CHEST Journal · doi:10.1016/j.chest.2020.08.002 · Cited by 66
Vena caval filters for the prevention of pulmonary embolism
Young, T., & Sriram, K. B. (2020) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006212.pub5 · Cited by 35
“Information regarding the indications is lacking, and short- and long-term complications of permanent and retrievable filters is incomplete (Brown 2017; Deso 2016).”
BackgroundDake, M. D., Murphy, T. P., Krämer, A. H., Darcy, M. D., Sewall, L. E., Curi, M. A., Johnson, M. S., Arena, F. J., Swischuk, J. L., Ansel, G. M., et al. (2018) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2018.05.009 · Cited by 34
A review of inferior vena cava filters
Sheahan, K. P., Tong, E., & Lee, M. J. (2022) · British Journal of Radiology · doi:10.1259/bjr.20211125 · Cited by 33
Gillespie, D. L., Spies, J. B., Siami, F. S., Rectenwald, J. E., White, R. A., & Johnson, M. S. (2019) · Journal of Vascular Surgery Venous and Lymphatic Disorders · doi:10.1016/j.jvsv.2019.07.009 · Cited by 27
A review of shape memory alloy based filtration devices
Yang, C., Abanteriba, S., & Becker, A. (2020) · AIP Advances · doi:10.1063/1.5133981 · Cited by 26
Current Controversies in Inferior Vena Cava Filter Placement: AJR Expert Panel Narrative Review
Kesselman, A. J., Oo, T. H., Johnson, M. S., Stecker, M. S., Kaufman, J. A., & Trost, D. (2020) · American Journal of Roentgenology · doi:10.2214/ajr.20.24817 · Cited by 26
Analysis of Swin-UNet vision transformer for Inferior Vena Cava filter segmentation from CT scans
Gomes, R., Pham, T., He, N., Kamrowski, C., & Wildenberg, J. C. (2023) · Artificial Intelligence in the Life Sciences · doi:10.1016/j.ailsci.2023.100084 · Cited by 25
Dake, M. D., Murphy, T. P., Krämer, A. H., Darcy, M. D., Sewall, L. E., Curi, M. A., Johnson, M. S., Arena, F. J., Swischuk, J. L., Ansel, G. M., et al. (2019) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2019.08.036 · Cited by 24
Deep Learning for Automated Classification of Inferior Vena Cava Filter Types on Radiographs
Ni, J., Shpanskaya, K. S., Han, M., Lee, E. H., Do, B. H., Kuo, W. T., Yeom, K. W., & Wang, D. S. (2019) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2019.05.026 · Cited by 24
Self-citationVena Cava Filters: Toward Optimal Strategies for Filter Retrieval and Patients' Follow-Up
Rezaei‐Kalantari, K., Rotzinger, D. C., & Qanadli, S. D. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.746748 · Cited by 23
Grewal, S., Lewandowski, R. J., Ryu, R. K., & Desai, K. R. (2020) · American Journal of Roentgenology · doi:10.2214/ajr.19.22387 · Cited by 23
“A high clinical suspicion for filter component perforation should be maintained in patients with a rIVCF in place who present with nonspecific abdominal or back pain [15].”
BackgroundAhmed, O. S., Sheikh, S., Tran, P., Funaki, B. S., Shadid, A. M., Navuluri, R., & Ha, T. V. (2019) · Canadian Association of Radiologists Journal · doi:10.1016/j.carj.2019.06.003 · Cited by 21
“The ALN (ALN Implants)filter is a stainless-steel retrievable filter cleared by FDA in 2008 (Figure 7) [1,11].”
BackgroundInfluentialAlshaqaq, H. M., Al-Sharydah, A. M., Alshahrani, M. S. S., Al-Qahtani, S. M., & Amer, M. R. (2023) · Journal of Intensive Care Medicine · doi:10.1177/08850666231163141 · Cited by 20
“Device geometry was reported to be a risk factor for certain IFRAE, where conical devices were reported to be associated with a higher risk of penetration, and filters with cylindrical or umbrella elements were reported to be associated with a higher risk of IVC thrombosis.(101) All IVC filters can be placed from tran…”
BackgroundElizondo, G., Eggers, M. D., Falcon, M., Trevino, M., Marrufo, R., Perez, C., Núñez, E., Moreno, R., Mitchell, A., Sheppard, A. L., et al. (2020) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2020.07.021 · Cited by 17
Hemodynamic Analysis of VenaTech Convertible Vena Cava Filter Using Computational Fluid Dynamics
Wang, J., Huang, W., Zhou, Y., Han, F., Ke, D., & Lee, C. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.556110 · Cited by 16
“The blood flow stasis is known as a factor of Virchow’s triad involved in intravascular thrombosis (Dickson, 2004) (the other two factors are endothelial damage/abnormality and hypercoagulability of flowing blood).”
BackgroundPosham, R., Fischman, A. M., Nowakowski, F., Bishay, V. L., Biederman, D. M., Virk, J., Kim, E., Patel, R. S., & Lookstein, R. (2017) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2017.02.030 · Cited by 15
Spanish multicenter real – life registry of retrievable vena cava filters (REFiVeC)
de Gregorio, M. Á., Guirola, J. A., Urbano, J., Díaz-Lorenzo, I., Muñoz, J. J., Villacastin, E., Lopez-Medina, A., Figueredo, A. L., Guerrero, J., Sierre, S., et al. (2020) · CVIR Endovascular · doi:10.1186/s42155-020-00114-5 · Cited by 16
Self-citationInterventional Radiology and Pregnancy: From Conception through Delivery and Beyond
Moirano, J., Khoury, J., Yeisley, C. D., Noor, A., & Voutsinas, N. (2023) · Radiographics · doi:10.1148/rg.230029 · Cited by 14
Li, M., Wang, J., Huang, W., Zhou, Y., & Song, X. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.1034120 · Cited by 13
“Many studies also show that the use of IVCF can be accompanied by many complications, including filter displacement, rupture, and embolism of the heart and pulmonary circulation by filter fragments (Deso et al., 2016; Ahmed et al., 2019; Li et al., 2020).”
BackgroundBistervels, I. M., Geerlings, A. E., Bonta, P. I., Ganzevoort, W., Zijlstra, I. A. J., & Middeldorp, S. (2021) · Blood Advances · doi:10.1182/bloodadvances.2020003930 · Cited by 12
“perforation.(2,10) Perforation of the vena cava wall by the IVC filter could be asymptomatic or require intervention when surrounding organs are involved.”
BackgroundLi, X., Feng, Y., Gong, Y., & Chen, Y. (2024) · Journal of Patient Safety · doi:10.1097/pts.0000000000001220 · Cited by 12
Randomized Controlled Study of an Absorbable Vena Cava Filter in a Porcine Model
Eggers, M. D., Rousselle, S. D., Urtz, M., Albright, R., Will, A., Jourden, B., Godshalk, C. P., Dria, S. J., Huang, S. Y., & Steele, J. R. (2019) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2019.03.010 · Cited by 11
Chassin-Trubert, L., Prouse, G., Ozdemir, B. A., Lounes, Y., Alonso, W., Clapiès, M., Alric, P., & Canaud, L. (2019) · Annals of Vascular Surgery · doi:10.1016/j.avsg.2018.11.021 · Cited by 10
Dake, M. D., Ansel, G. M., Johnson, M. S., Mendes, R., & Smouse, H. B. (2019) · International Journal of Vascular Medicine · doi:10.1155/2019/5795148 · Cited by 9
“A number of studies and case reports have been published describing time-dependent complications — such as tilting, fracture, embolization, migration, or IVC perforation — associated with retrievable IVC filters that remain indwelling [7].”
BackgroundInfluentialGaines, P. A., Kolodgie, F. D., Crowley, G., Horan, S., MacDonagh, M., McLucas, E., Rosenthal, D., Strong, A., Sweet, M., & Panchal, D. K. (2018) · International Journal of Vascular Medicine · doi:10.1155/2018/6981505 · Cited by 9
Predicting inferior vena cava filter complications using machine learning
Li, B., Eisenberg, N., Beaton, D., Lee, D. S., Al‐Omran, L., Wijeysundera, D. N., Hussain, M. A., Rotstein, O. D., de Mestral, C., Mamdani, M., et al. (2024) · Journal of Vascular Surgery Venous and Lymphatic Disorders · doi:10.1016/j.jvsv.2024.101943 · Cited by 8
Gabara, C., Montoya-Rodés, M., López, N., Zamora, C., Ortiz, M., Morancho, A., Moisés, J., Osorio, J., Coloma, E., Font, C., et al. (2023) · Angiology · doi:10.1177/00033197231190184 · Cited by 7
Back to the Basics: Inferior Vena Cava Filters
Covello, B. R., & Radvany, M. G. (2022) · Seminars in Interventional Radiology · doi:10.1055/s-0042-1751294 · Cited by 7
Liu, W., Zhang, Y., & Zhang, L. (2021) · Contrast Media & Molecular Imaging · doi:10.1155/2021/9092836 · Cited by 7
“Its good performance and safety improve the success rate of punctures [17].”
BackgroundHinojosa, C. A., Lizola, R., Laparra-Escareño, H., & Anaya‐Ayala, J. E. (2017) · BMJ Case Reports · doi:10.1136/bcr-2016-218697 · Cited by 7
Fioretti, A. M., Forgia, D. L., Scicchitano, P., Brunetti, N. D., Inchingolo, R., Tocchetti, C. G., & Oliva, S. (2024) · Biomedicines · doi:10.3390/biomedicines12102230 · Cited by 6
“[15].”
Shaikh, S. S., Kamath, S. D., Ghosh, D., Lewandowski, R. J., & McMahon, B. J. (2020) · International Journal of Vascular Medicine · doi:10.1155/2020/6582742 · Cited by 6
Ho, K. M., Patel, P., Chamberlain, J., Nasim, S., & Rogers, F. B. (2022) · European Journal of Trauma and Emergency Surgery · doi:10.1007/s00068-022-02074-y · Cited by 6
Robins, J. E., Ragai, I., & Yamaguchi, D. J. (2018) · Journal of Vascular Surgery Venous and Lymphatic Disorders · doi:10.1016/j.jvsv.2017.10.019 · Cited by 6
Inferior vena cava filter use at a large community hospital: a retrospective cohort study
Fontyn, S., Bai, Y., Bolger, S., Greco, K., Wang, T., Hamm, C. M., & Cervi, A. (2024) · Scientific Reports · doi:10.1038/s41598-024-60868-z · Cited by 5
Vilanilam, G. K., Maynard, N. K., Palmer, A. W., Moore, J., Kamran, M., & Radvany, M. G. (2021) · Clinical Imaging · doi:10.1016/j.clinimag.2021.01.041 · Cited by 5
Leiderman, D. B. D., da Silva, M. F. A., Teivelis, M. P., Stabellini, N., Amaro, E., & Wolosker, N. (2022) · Jornal Vascular Brasileiro · doi:10.1590/1677-5449.20210186 · Cited by 5
Wiske, C. P., Harish, K. B., & Maldonado, T. S. (2023) · Springer eBooks · doi:10.1007/978-3-030-70904-4_74-1 · Cited by 5
Shimoo, S., & Koide, M. (2020) · Radiology Case Reports · doi:10.1016/j.radcr.2020.05.019 · Cited by 5
Khan, W., Zhang, W., & Clark, V. (2021) · Cureus · doi:10.7759/cureus.13168 · Cited by 5
“Our patient received a Celect filter which has a conical shape that is more commonly associated with a high rate of penetration versus other types of IVC filters [11-13].”
BackgroundAhmad, Y., Funaki, B. S., Jilani, S., & Ahmed, O. S. (2022) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2022.07.010 · Cited by 5
Inferior Vena Cava Filter Retrieval: Simple to Complex
Swersky, A., & Desai, K. R. (2024) · CardioVascular and Interventional Radiology · doi:10.1007/s00270-024-03673-5 · Cited by 4
Kadakia, K. T., Bikdeli, B., Gupta, A., Dhruva, S. S., Ross, J. S., & Krumholz, H. M. (2024) · Annals of Internal Medicine · doi:10.7326/annals-24-00089 · Cited by 4
Bikdeli, B., Kirtane, A. J., Jiménez, D., Green, P., Spencer, F. A., Kuo, W. T., Krumholz, H. M., & Parikh, S. A. (2019) · Clinical and Applied Thrombosis/Hemostasis · doi:10.1177/1076029619849111 · Cited by 4
“Therefore, it underestimates the number of complications.(10) In this study, we complemented our assessment of MAUDE with that of published reports of hemopericardium.”
ResultSelf-citationKnobloch, G., Nagle, S. K., Colgan, T. J., Schubert, T. B., Johnson, K. M., Bannas, P., Li, G., Hinshaw, L. A., Holmes, J. H., & Reeder, S. B. (2020) · Abdominal Radiology · doi:10.1007/s00261-020-02548-w · Cited by 4
Hansmann, J., Sheybani, A., Minocha, J., Bui, J. T., Lipnik, A. J., Shah, K. Y., Niemeyer, M. M., Gaba, R. C., & Ray, C. E. (2019) · Clinical Neurology and Neurosurgery · doi:10.1016/j.clineuro.2019.02.016 · Cited by 4
Slyško, R., Vulev, I., & Smoter, Š. (2025) · Bratislavské lekárske listy/Bratislava medical journal · doi:10.1007/s44411-025-00028-5 · Cited by 4
“It is more common with permanent filters [6].”
Art and Challenges Involved in the Treatment of Ischaemic Damage
Sáiz‐Sapena, N., Aparici, F., & Tsoulfas, G. (2021) · IntechOpen eBooks · doi:10.5772/intechopen.94682 · Cited by 3
Use of Vena Cava Filters and Venous Access Devices
Rajasekhar, A., & Streiff, M. B. (2019) · Elsevier eBooks · doi:10.1016/b978-0-323-46202-0.00030-3 · Cited by 3
Кириенко, А. И., Andriyashkin, V. V., & Иванов, В. В. (2018) · Journal of Venous Disorders · doi:10.17116/flebo20181214-11 · Cited by 3
Management of Pulmonary Thromboembolism
Kiran, G. R. (2022) · IntechOpen eBooks · doi:10.5772/intechopen.100040 · Cited by 3
A prospective ex vivo biomechanical analysis of retrievable inferior vena cava filters
Ho, K. M., Chamberlain, J., Nasim, S., Rogers, F. B., & Kop, A. M. (2022) · Journal of Vascular Surgery Venous and Lymphatic Disorders · doi:10.1016/j.jvsv.2022.04.007 · Cited by 3
Comparison of success and cost after retrieval of two inferior vena cava filters
Bhinder, J., O’Brien-Irr, M. S., Chang, M., Montross, B. C., Khan, S. Z., Dosluoglu, H. H., & Harris, L. M. (2023) · Journal of Vascular Surgery Venous and Lymphatic Disorders · doi:10.1016/j.jvsv.2023.09.001 · Cited by 3
Layfield, E. M., Stavropoulos, S. W., Chittams, J. L., Quinn, R., & Trerotola, S. O. (2020) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2020.07.006 · Cited by 2
Successful endovascular retrieval of an inferior vena cava filter penetrating into aorta
Hudák, M., Koščo, M., & Rašiová, M. (2023) · Journal of Cardiology Cases · doi:10.1016/j.jccase.2023.08.001 · Cited by 2
Inferior Vena Cava Filters—Current Role and Controversies
Kapoor, H., & Raissi, D. (2019) · Journal of Clinical Interventional Radiology ISVIR · doi:10.1055/s-0039-1685236 · Cited by 2
Hansmann, J., Kuei, A., Patel, M., Albright, W. J., Bui, J. T., Williams, D. M., Sherk, W. M., Kazanjian, S., Powell, C. C., Ray, C. E., et al. (2022) · Journal of Vascular Surgery Venous and Lymphatic Disorders · doi:10.1016/j.jvsv.2022.01.012 · Cited by 2
Candemir, S., Moranville, R., Wong, K. A., Campbell, W. A., Bigelow, M. T., Prevedello, L. M. S., & Makary, M. S. (2023) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-023-00882-1 · Cited by 2
“From 1980 to 2014, there have only been unique 23 filter types passing FDA clearance [26].”
BackgroundMcElhinney, D. B. (2017) · Circulation Cardiovascular Interventions · doi:10.1161/circinterventions.117.005662 · Cited by 2
Kossa, A., & McMeeking, R. M. (2021) · Journal of Elasticity · doi:10.1007/s10659-021-09850-8 · Cited by 1
(The inferior vena cava filter and complications associated with its use)
Hudák, M., Koščo, M., Dekanová, L., Pavlíková, V., Szabóová, E., & Rašiová, M. (2024) · Cor et Vasa · doi:10.33678/cor.2024.015 · Cited by 1
Zhao, B., Jiang, R., Gong, M., He, X., Kong, J., Liu, Z., & Gu, J. (2024) · Annals of Vascular Surgery · doi:10.1016/j.avsg.2024.09.057 · Cited by 1
Preliminary Exploration of CBCT in IVCFT Patient Filter Retrieval
Zhu, J., Geng, Y., Xu, Z., Jiang, M., & Xu, Y. (2025) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.70048 · Cited by 1
Wang, R., Zhou, X., Su, L., & Qu, G. (2026) · Forensic Science Medicine and Pathology · doi:10.1007/s12024-025-01080-x · Cited by 1
Carr, I. A., Aycock, K. I., Paranjape, H. M., Bonsignore, C., Weaver, J. D., & Craven, B. A. (2026) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-026-00837-x · Cited by 1
Bundy, J. J., Campbell, W. A., Abad-Santos, M., Shin, D. S., Chick, J. F. B., & Makary, M. S. (2026) · CVIR Endovascular · doi:10.1186/s42155-026-00678-8 · Cited by 1
“The observed rate of thrombotic occlusion of the IVC in patients with “permanent” filters is 6–30%; similar to the reported rate of 2–30% seen with retrievable filters [4, 17, 18].”
Кириенко, А. И., Andriyashkin, V. V., & Иванов, В. В. (2018) · Medical Herald of the South of Russia · doi:10.21886/2219-8075-2018-9-4-42-48 · Cited by 1
Gabara Xancó, C. (2024) · Dipòsit Digital de la Universitat de Barcelona (Universitat de Barcelona) · Cited by 1
Inferior Vena Cava Filter Placement With Catheter-Directed Lysis
Crowther, M. A., & Cervi, A. L. (2018) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2018.06.013
A Review of the Currently Available Retrievable and Next Generation Inferior Vena Cava Filters
Sucher, A., Thant, M., & Abujudeh, H. H. (2019) · Current Radiology Reports · doi:10.1007/s40134-019-0341-9
Complex Filter Retrieval Planning
Gordon, A. C., Desai, K. R., & Lewandowski, R. J. (2020) · Springer eBooks · doi:10.1007/978-3-030-45150-9_5
Inferior Vena Cava Filters in Venous Thromboembolism
Marron, R. M., Rali, P. M., & Bull, T. (2020) · Respiratory medicine · doi:10.1007/978-3-030-51736-6_9
Inferior vena cava filter thrombosis: An overview
Gu, J., Razi, M., He, X., & Ahmed, M. J. (2020) · Indian Journal of Vascular and Endovascular Surgery · doi:10.4103/ijves.ijves_118_20
Over-the-Wire Inferior Vena Cava Filter Placement: How We Do It
Li, X., Montgomery, J. P., Kirksey, L., Gadani, S. D., D'Amico, G., & Partovi, S. (2021) · Seminars in Interventional Radiology · doi:10.1055/s-0041-1727102
Prophylaxis of venous thromboembolism in critically ill patients
Cihlář, R., Šrámek, V., & Suk, P. (2021) · Anesteziologie a intenzivní medicína · doi:10.36290/aim.2021.046
Inferior vena cava filters: a review
Barajas‐Colón, J. Á., Barrera‐Mera, B., Banegas-Ruíz, R., Vargas-Morales, J. J., Barrera-Calva, E., Castillo-Martínez, D. B., Chávez, O. H. G., Soulé-Martínez, C. E., Gómez-Mendoza, F. F., Mendoza-Aceves, R. A., et al. (2021) · International Journal of Research in Medical Sciences · doi:10.18203/2320-6012.ijrms20213108
Changes in perfusion angiography after IVC filter placement and retrieval
Shreve, L., Lam, A. H., Badin, D. J., Nelson, K. J., Katrivesis, J., Fernando, D. M., & Abi‐Jaoudeh, N. (2022) · Medicine · doi:10.1097/md.0000000000031600
“Comparisons of multiple filter types have shown that filter geometry plays a significant role in determining the flow dynamics, complications of a filter, and rates of filter thrombosis.[21,37] The study presented here primarily assessed the Cook Celect filter (N = 40/41), as this is the filter used at our particular…”
MethodResultRetrievable Inferior Vena Cava Filters: A 10-Year Retrospective Analysis
Sum, R., & Lau, K. (2023) · Hong Kong Journal of Radiology · doi:10.12809/hkjr2317347
7 Inferior Vena Caval and Right Atrial ThrombusRight atrial (RA) thrombusInferior vena cava (IVC)
(2024) · Thieme Medical Publishers eBooks · doi:10.1055/b-0044-205264
5 Inferior Vena Cava Filter PlacementInferior vena cava (IVC) filter placement
(2024) · Thieme Medical Publishers eBooks · doi:10.1055/b-0044-205262
Wiske, C. P., Harish, K. B., & Maldonado, T. S. (2024) · Springer eBooks · doi:10.1007/978-3-030-70904-4_74-2
Interruption partielle de la veine cave inférieure : les filtres caves
Catella, J., Hafdi, L., Grange, S., & Bertoletti, L. (2025) · EMC - Angéiologie · doi:10.1016/s2211-0364(24)49477-6
Nakata, M., Yokota, N., Uehara, H., Tabata, K., & Kenzaka, T. (2025) · BMC Cardiovascular Disorders · doi:10.1186/s12872-025-05062-3
Outcomes of inferior vena cava filtration in lung transplant recipients
Naser-Tavakolian, K., Sajan, A., Krishnasamy, V. P., Mabud, T. S., Filtes, J., Baig, A., Sarkar, D., & Reis, S. P. (2026) · Frontiers in Radiology · doi:10.3389/fradi.2026.1796398
Ishida, K., Sato, Y., Uekita, H., & Haga, J. (2026) · FUKUSHIMA JOURNAL OF MEDICAL SCIENCE · doi:10.5387/fms.25-00010
Chen, R., Liu, C., Pan, H., Han, B., & Hu, H. (2026) · Journal of Cardiothoracic Surgery · doi:10.1186/s13019-026-03883-7
Inferior Vena Cava Filter Evaluation on CT: What the Radiologist Needs to Know
Savsani, E., Lukse, R., Kania, L. M., Udare, A. S., Roth, C. G., & Naringrekar, H. (2026) · Roentgen Ray Review · doi:10.2214/r3j.25.01125
A History of Vena Cava Interruption to Treat Pulmonary Embolism: The Ben Hogan Case
Pappas, T. N., Lim, T., & Barr, J. (2026) · Ochsner Journal · doi:10.31486/toj.26.0038
“66,67 Because filters seemed to minimize complications while effectively preventing blood clots, filter use increased rapidly.”
Strategies Associated With High Inferior Vena Cava Filter Retrieval: A Positive Deviance Study
Trivedi, P. S., Barnard, J. G., Gurfinkel, D., Baron, M. P., Lindquist, J. D., Bai, H., & Ho, P. M. (2026) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2026.07.002 · Cited by 1
Zhang, H., Wu, Y., Tang, Z., Keese, M. A., Wen, F., & Guo, F. (2026) · Frontiers in Surgery · doi:10.3389/fsurg.2026.1895441
Inferior Vena Cava Filters: Relevant Issues for Hospitalists and Intensivists
Valbuena, J., vanSonnenberg, E., & Walker, T. G. (2026) · Journal of Intensive Care Medicine · doi:10.1177/08850666261469135
Wiske, C. P., Harish, K. B., & Maldonado, T. (2026) · Springer eBooks · doi:10.1007/978-3-030-70904-4_74-3
Advances in Design and Preparation of Biodegradable Inferior Vena Cava Filters
Shen, J., Li, H., & Ye, L. (2026) · Materials · doi:10.3390/ma19204282
“Conical filters use struts converging toward a central apex, whereas biconical filters incorporate opposing conical elements [12].”
Superior Vena Cava Filters during upper extremity DVT thrombectomy: a good idea?
Catella, J., & Stacoffe, N. (2026) · Research and Practice in Thrombosis and Haemostasis · doi:10.1016/j.rpth.2026.107061
Metadata
- Authors
- Idakoji, I., Kuo, W., & Deso, S.
- Affiliations
- Stanford Medicine (US)
- Corresponding author
- Deso, Steven
- ORCID
- Kuo, William
- Venue
- Seminars in Interventional Radiology
- Publisher
- Georg Thieme Verlag KG
- Published
- 2016-05-10
- Volume
- 33
- Issue
- 02
- Pages
- 093-100
- ISSN
- 0739-9529 (ISSN-L)
- 1098-8963
- PMC
- PMC4862854
- OpenAlex
- W2415693239
- Cited by
- 93
- References
- 90
- Citations by year
- 2026: 11 · 2025: 4 · 2024: 11 · 2023: 9 · 2022: 10 · 2021: 10 · 2020: 16 · 2019: 12 · 2018: 6 · 2017: 3 · 2016: 1
- FWCI
- 1.31
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Seminars in Interventional Radiology (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Tufts University School of Medicine
- Topics
- Health Sciences › Medicine › Internal Medicine › Venous Thromboembolism Diagnosis and Management
- Health Sciences › Medicine › Surgery › Vascular anomalies and interventions
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Central Venous Catheters and Hemodialysis
- Keywords
- inferior vena cava filter, IVC filter complications, filter type, inferior vena cava thrombosis, filter fracture, filter retrieval, FDA-approved devices
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.