Percutaneous inferior vena caval filters: follow-up of seven designs in 320 patients.
Abstract
Three hundred twenty-four percutaneous inferior vena caval (IVC) filters of different designs were placed in 320 patients from April 1985 through June 1992. No acute mortality or substantial morbidity was attributed to filter placement. Radiologic or pathologic follow-up data were obtained in 227 (71%) patients (230 filters); clinical follow-up data only were obtained in 50 (16%) patients (50 filters). One hundred twenty (43%) patients died; post-filter-placement pulmonary emboli (PE) were related to the cause of death in eight. At IVC filter imaging studies, 26 of 137 (19%) filters demonstrated caval thrombus; 12 of 132 (9%) filters had delayed penetration through the IVC wall of greater than 3 mm; 13 of 230 (6%) filters migrated more than 1 cm; and five of 230 (2%) filters had fracture of a strut or leg. Deep venous thrombosis (DVT) at the insertion puncture site or in the lower extremity was noted in 26 of 117 (22%) cases of filter placement. Among patients without imaging studies, clinical suspicion of complications included PE in four patients, IVC thrombus in 14 patients, and lower-extremity DVT in 10 patients. Long-term clinical and radiologic follow-up of all IVC filters is indicated due to the relatively high prevalence of some complications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Guidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Torbicki, A., Perrier, A., Konstantinides, S., Agnelli, G., Galiè, N., Pruszczyk, P., Bengel, F., Brady, A. J. B., Ferreira, D., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn310 · Cited by 2,826
Rogers, F. B., Cipolle, M. D., Velmahos, G., Rozycki, G., & Luchette, F. A. (2002) · The Journal of Trauma: Injury, Infection, and Critical Care · doi:10.1097/00005373-200207000-00032 · Cited by 713
Vena caval filters: a comprehensive review
Streiff, M. B. (2000) · Blood · doi:10.1182/blood.v95.12.3669 · Cited by 370
Inferior Vena Caval Filters: Review of a 26-year Single-Center Clinical Experience
Athanasoulis, C. A., Kaufman, J. A., Halpern, E. F., Waltman, A. C., Geller, S. C., & Fan, C.-M. (2000) · Radiology · doi:10.1148/radiology.216.1.r00jl1254 · Cited by 370
Caplin, D. M., Nikolic, B., Kalva, S. P., Ganguli, S., Saad, W. E. A., & Zuckerman, D. A. (2011) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2011.07.012 · Cited by 278
Metadata
- Authors
- Ferris, E. J., McCowan, T. C., Carver, D. K., & McFarland, D. R.
- Venue
- Radiology
- Published
- 1993-09
- Volume
- 188
- Issue
- 3
- Pages
- 851-856
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2011389832
- Cited by
- 301
- References
- 0
- FWCI
- 9.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Percutaneous inferior vena caval filters: follow-up of seven designs in 320 patients. https://app.cochat.ai/papers/10.1148/radiology.188.3.8351361
- The paper
- Ferris, E. J., McCowan, T. C., Carver, D. K., & McFarland, D. R. (1993). Percutaneous inferior vena caval filters: follow-up of seven designs in 320 patients. Radiology. https://doi.org/10.1148/radiology.188.3.8351361
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.