CoChat

Inter-laboratory Variability of Anti-β2-glycoprotein I Measurement: A Collaborative Study in the Frame of the European Forum on Antiphospholipid Antibodies Standardization Group

Schousboe, Inger, Tincani, Angela, Sanmarco, Marielle, Kveder, Tanja, de Moerloose, Philippe, Boffa, Marie-Claire, Arvieux, Josiane, Reber, Guido · 2002 · Thrombosis and Haemostasis
Cited by 90

The DOI matches its Crossref record.

Abstract

Summary: Inter-laboratory variability of anti-β2-glycoprotein I antibody measurements (IgG and IgM) was investigated in the frame of the European Forum on Antiphospholipid Antibodies and its Standardization Group. Twenty-eight samples from patients with autoimmune diseases, two samples from blood donors and a set of six calibrators obtained by dilution with normal plasma of a pool of patient samples were sent to 21 European centers. Six of them used commercial kits and the others home-made assays. Marked differences in the steepness of the calibration curves obtained with the calibrator provided were observed. The standard deviations of sample measurement were high. Cut-off of positivity varied from 7 to 90 Forum Units (FU) for IgG and from 10 to 138 FU for IgM, whereas the rate of positivity varied from 50 to 93% for IgG and from 13 to 70% for IgM. No clear relationship between cut-off values and positivity rate could be established for either isotype. Adopting a common cut-off did not markedly improve the overall agreement between centers in positive/negative sample classification. Because of the majority of low positive samples, excellent concordance between centers (as defined by kappa values from 0.8 and 1) occurred only in 13% of cases for IgG and in 6% of cases for IgM, because many selected samples were low-positive. Despite the large variability of anti-β2-glycoprotein I measurements between centers, the agreement on results with highand medium-positive samples was good.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1055/s-0037-1613156

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 90

Metadata

Authors
Schousboe, I., Tincani, A., Sanmarco, M., Kveder, T., de Moerloose, P., Boffa, M.-C., Arvieux, J., & Reber, G.
Venue
Thrombosis and Haemostasis
Published
2002
Volume
88
Issue
07
Pages
66-73
ISSN
  • 0340-6245 (ISSN-L)
  • 2567-689X
OpenAlex
W4324264883
Cited by
90
References
0
FWCI
6.47
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Inter-laboratory Variability of Anti-β2-glycoprotein I Measurement: A Collaborative Study in the Frame of the European Forum on Antiphospholipid Antibodies Standardization Group. https://app.cochat.ai/papers/10.1055/s-0037-1613156
The paper
Schousboe, I., Tincani, A., Sanmarco, M., Kveder, T., de Moerloose, P., Boffa, M.-C., Arvieux, J., & Reber, G. (2002). Inter-laboratory Variability of Anti-β2-glycoprotein I Measurement: A Collaborative Study in the Frame of the European Forum on Antiphospholipid Antibodies Standardization Group. Thrombosis and Haemostasis. https://doi.org/10.1055/s-0037-1613156

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.